Non-invasive estimation of intracranial pressure. MR-based evaluation in children with hydrocephalus

被引:0
|
作者
Muehlmann, M. [1 ]
Steffinger, D. [1 ]
Peraud, A. [2 ]
Lehner, M. [3 ]
Heinen, F. [4 ]
Alperin, N. [4 ]
Ertl-Wagner, B. [1 ]
Koerte, I. K. [1 ]
机构
[1] Univ Munich, Inst Klin Radiol, D-80336 Munich, Germany
[2] Univ Munich, Abt Neurochirurg, D-80336 Munich, Germany
[3] Univ Munich, Abt Kinderchirurg, Dr von Haunersches Kinderspital, D-80336 Munich, Germany
[4] Univ Miami, Miller Sch Med, Dept Radiol, Coral Gables, FL 33124 USA
来源
RADIOLOGE | 2012年 / 52卷 / 09期
关键词
Hydrocephalus; Intracranial pressure; Phase contrast imaging; Non-invasive method; Diagnostic imaging; DOPPLER PULSATILITY INDEX; TYMPANIC MEMBRANE DISPLACEMENT; OPTICAL COHERENCE TOMOGRAPHY; NEAR-INFRARED SPECTROSCOPY; BRAIN-INJURY; ICP; EXPERIENCE; NERVE;
D O I
10.1007/s00117-012-2326-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The intracranial pressure (ICP) is a crucially important parameter for diagnostic and therapeutic decision-making in patients with hydrocephalus. So far there is no standard method to non-invasively assess the ICP. Various approaches to obtain the ICP semi-invasively or non-invasively are discussed and the clinical application of a magnetic resonance imaging (MRI)-based method to estimate ICP (MR-ICP) is demonstrated in a group of pediatric patients with hydrocephalus. Arterial inflow, venous drainage and craniospinal cerebrospinal fluid (CSF) flow were quantified using phase-contrast imaging to derive the MR-ICP. A total of 15 patients with hydrocephalus (n=9 treated with shunt placement or ventriculostomy) underwent MRI on a 3 T scanner applying retrospectively-gated cine phase contrast sequences. Of the patients six had clinical symptoms indicating increased ICP (age 2.5-14.61 years, mean 7.4 years) and nine patients had no clinical signs of elevated ICP (age 2.1-15.9 years; mean 9.8 years; all treated with shunt or ventriculostomy). Median MR-ICP in symptomatic patients was 24.5 mmHg (25th percentile 20.4 mmHg; 75th percentile 44.6 mmHg). Median MR-ICP in patients without acute signs of increased ICP was 9.8 mmHg (25th percentile 8.6 mmHg; 75th percentile 11.4 mmHg). Group differences were significant (p < 0.001; Mann-Whitney U-test). The MR-ICP technique is a promising non-invasive tool for estimating ICP. Further studies in larger patient cohorts are warranted to investigate its application in children with hydrocephalus.
引用
收藏
页码:827 / 832
页数:6
相关论文
共 50 条
  • [31] Non-Invasive Intracranial Pressure Estimation During Combined Exposure to CO2 and Head-Down Tilt
    Kurazumi, Takuya
    Ogawa, Yojiro
    Yanagida, Ryo
    Morisaki, Hiroshi
    Iwasaki, Ken-ichi
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2018, 89 (04) : 365 - 370
  • [32] A pilot study for continuous non-invasive intracranial pressure screening
    Pose, Fernando
    Videla, Carlos
    Campanini, Giovanni
    Redelico, Francisco O.
    Ciarrocchi, Nicolas
    Computers in Biology and Medicine, 2025, 186
  • [33] Intracranial pressure in microgravity conditions: non-invasive assessment by ophthalmodynamometry
    Draeger, J
    Rumberger, E
    Hechler, B
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1999, 70 (12): : 1227 - 1229
  • [34] Monitoring intracranial pressure using non-invasive brain stethoscope
    Azad, Md Khurshidul
    Spiewak, Andrew
    Sandler, Richard H.
    Manwaring, Kim
    Manwaring, Preston
    Mansy, Hansen A.
    IEEE SOUTHEASTCON 2018, 2018,
  • [35] Non-invasive detection of intracranial pressure related to the optic nerve
    Li, Jian
    Wan, Chao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (06) : 2823 - 2836
  • [36] Non-Invasive Intracranial Pressure Monitoring and Its Applicability in Spaceflight
    Felix, Hugo
    Oliveira, Edson Santos
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2022, 93 (06) : 517 - 531
  • [37] A machine learning approach in the non-invasive prediction of intracranial pressure using Modified Photoplethysmography
    Abdul-Rahman, Anmar
    Morgan, William
    Yu, Dao-Yi
    PLOS ONE, 2022, 17 (09):
  • [38] Measuring intracranial pressure by invasive, less invasive or non-invasive means: limitations and avenues for improvement
    Karen Brastad Evensen
    Per Kristian Eide
    Fluids and Barriers of the CNS, 17
  • [39] New non-invasive sonographic modality for intracranial pressure/volume monitoring
    Fountas K.N.
    Sitkauskas A.
    Troup E.C.
    Feltes C.H.
    Dimopoulos V.
    Deltuva V.
    Daubaris G.
    Ragauskas A.
    Robinson Jr. J.S.
    Child’s Nervous System, 2002, 18 (5) : 211 - 214
  • [40] Non-invasive assessment of intracranial pressure through the eyes: current developments, limitations, and future directions
    Viarsagh, Solmaz Bastani
    Agar, Ashish
    Lawlor, Mitchell
    Fraser, Clare
    Golzan, Mojtaba
    FRONTIERS IN NEUROLOGY, 2024, 15