Realistic Simulation of Regional Myocardial Perfusion Defects for Cardiac SPECT Studies

被引:0
|
作者
Fung, George S. K. [1 ]
Segars, W. Paul [2 ]
Lee, Taek-Soo [1 ]
Higuchi, Takahiro [1 ]
Veress, Alexander I. [3 ]
Gullberg, Grant T. [4 ]
Tsui, Benjamin M. W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21218 USA
[2] Duke Univ, Dept Radiol, Durham, NC USA
[3] Univ Washington, Dept Engn Mech, Seattle, WA USA
[4] Lawrence Berkeley Natl Lab, Berkeley, CA USA
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
PHANTOM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The current 3D XCAT phantom allows users to manually define the regional myocardial perfusion defect (MPD) as a simple pie-shaped wedge region with reduced activity level in the myocardium of left ventricle. To more accurately and realistically model the MPD, we have developed a new regional MPD model for the 3D XCAT phantom for myocardial perfusion SPECT (MP-SPECT) studies based on the location and the severity of the stenosis in a computer generated coronary arterial tree. First, we generated a detailed coronary arterial tree by extending the large proximal branches segmented from patient CT images to cover the whole heart using an iterative rule-based algorithm. Second, we determined the affected downstream vascular segments of a given stenosis. Third, we computed the activity of each myocardial region as a function of the inverse-distance-weighted average of the flow of the neighboring vascular segments. Fourth, we generated a series of bull's-eye maps of MP-SPECT images of different coronary artery stenosis scenarios. Fifth, we had expert physician readers to qualitatively assess the bull's-eye maps based on their similarity to typical clinical cases in terms of the shape, the extent, and the severity of the MPDs. Their input was used to iteratively revise the coronary artery tree model so that the MPDs were closely matched to those found in bull's-eye maps from patient studies. Finally, from our simulated MP-SPECT images, we observed that (1) the locations of the MPDs caused by stenoses at different main arteries were different largely according to their vascular territories, (2) a stenosis at a proximal branch produced a larger MPD than the one at a distal branch, and (3) a more severe stenosis produced a larger MPD than the less severe one. These observations were consistent to those found in clinical cases. Therefore, this new regional MPD model has enhanced the generation of realistic pathological MP-SPECT images using the XCAT phantom. When combining with the mechanical model of the myocardium, the new model can be extended for the simulation of 4D gated MP-SPECT simulation of a pathological heart with both perfusion and motion defects.
引用
收藏
页码:3061 / 3064
页数:4
相关论文
共 26 条
  • [21] Impact of Resolution Recovery in Quantitative 99mTc SPECT/CT Cardiac Phantom Studies
    Ismail, Faizatul Shahira
    Mansor, Syahir
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (03) : 449 - 453
  • [22] Deep learning-based denoising in projection-domain and reconstruction-domain for low-dose myocardial perfusion SPECT
    Sun, Jingzhang
    Jiang, Han
    Du, Yu
    Li, Chien-Ying
    Wu, Tung-Hsin
    Liu, Yi-Hwa
    Yang, Bang-Hung
    Mok, Greta S. P.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (03) : 970 - 985
  • [23] Pixel-wise assessment of cardiovascular magnetic resonance first-pass perfusion using a cardiac phantom mimicking transmural myocardial perfusion gradients
    Milidonis, Xenios
    Nazir, Muhummad Sohaib
    Schneider, Torben
    Capstick, Myles
    Drost, Sita
    Kok, Gertjan
    Pelevic, Nikola
    Poelma, Christian
    Schaeffter, Tobias
    Chiribiri, Amedeo
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2871 - 2884
  • [24] Deep-learning-based estimation of attenuation map improves attenuation correction performance over direct attenuation estimation for myocardial perfusion SPECT
    Du, Yu
    Shang, Jingjie
    Sun, Jingzhang
    Wang, Lu
    Liu, Yi-Hwa
    Xu, Hao
    Mok, Greta S. P.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (03) : 1022 - 1037
  • [25] Myocardial Perfusion Imaging Using 99mTc-MIBI Single Photon Emission Computed Tomography: A Cardiac Phantom Study
    Almoudi, Mansour
    Sun, Zhonghua
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (04) : 480 - 486
  • [26] Patient effective radiation dose and associated risk from transmission scans using 153Gd line sources in cardiac spect studies
    Perisinakis, K
    Theocharopoulos, N
    Karkavitsas, N
    Damilakis, J
    HEALTH PHYSICS, 2002, 83 (01): : 66 - 74