Realistic Simulation of Regional Myocardial Perfusion Defects for Cardiac SPECT Studies

被引:0
|
作者
Fung, George S. K. [1 ]
Segars, W. Paul [2 ]
Lee, Taek-Soo [1 ]
Higuchi, Takahiro [1 ]
Veress, Alexander I. [3 ]
Gullberg, Grant T. [4 ]
Tsui, Benjamin M. W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21218 USA
[2] Duke Univ, Dept Radiol, Durham, NC USA
[3] Univ Washington, Dept Engn Mech, Seattle, WA USA
[4] Lawrence Berkeley Natl Lab, Berkeley, CA USA
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
PHANTOM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The current 3D XCAT phantom allows users to manually define the regional myocardial perfusion defect (MPD) as a simple pie-shaped wedge region with reduced activity level in the myocardium of left ventricle. To more accurately and realistically model the MPD, we have developed a new regional MPD model for the 3D XCAT phantom for myocardial perfusion SPECT (MP-SPECT) studies based on the location and the severity of the stenosis in a computer generated coronary arterial tree. First, we generated a detailed coronary arterial tree by extending the large proximal branches segmented from patient CT images to cover the whole heart using an iterative rule-based algorithm. Second, we determined the affected downstream vascular segments of a given stenosis. Third, we computed the activity of each myocardial region as a function of the inverse-distance-weighted average of the flow of the neighboring vascular segments. Fourth, we generated a series of bull's-eye maps of MP-SPECT images of different coronary artery stenosis scenarios. Fifth, we had expert physician readers to qualitatively assess the bull's-eye maps based on their similarity to typical clinical cases in terms of the shape, the extent, and the severity of the MPDs. Their input was used to iteratively revise the coronary artery tree model so that the MPDs were closely matched to those found in bull's-eye maps from patient studies. Finally, from our simulated MP-SPECT images, we observed that (1) the locations of the MPDs caused by stenoses at different main arteries were different largely according to their vascular territories, (2) a stenosis at a proximal branch produced a larger MPD than the one at a distal branch, and (3) a more severe stenosis produced a larger MPD than the less severe one. These observations were consistent to those found in clinical cases. Therefore, this new regional MPD model has enhanced the generation of realistic pathological MP-SPECT images using the XCAT phantom. When combining with the mechanical model of the myocardium, the new model can be extended for the simulation of 4D gated MP-SPECT simulation of a pathological heart with both perfusion and motion defects.
引用
收藏
页码:3061 / 3064
页数:4
相关论文
共 26 条
  • [11] Dual gating myocardial perfusion SPECT denoising using a conditional generative adversarial network
    Sun, Jingzhang
    Zhang, Qi
    Du, Yu
    Zhang, Duo
    Pretorius, P. Hendrik
    King, Michael A.
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2022, 49 (08) : 5093 - 5106
  • [12] Effect of respiratory motion on quantitative myocardial gated SPECT: a simulation study
    Bitarafan-Rajabi, Ahmad
    Rajabi, Hossein
    Rastgou, Feridoon
    Sharafi, Ali Akbar
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (06) : 587 - 593
  • [13] Dual "motion-frozen heart" combining respiration and contraction compensation in clinical myocardial perfusion SPECT imaging
    Kovalski, Gil
    Keidar, Zohar
    Frenkel, Alex
    Sachs, Jonathan
    Attia, Shai
    Azhari, Haim
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (03) : 396 - 404
  • [14] Interpolated CT for attenuation correction on respiratory gating cardiac SPECT/CT - A simulation study
    Zhang, Duo
    Ghaly, Michael
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2019, 46 (06) : 2621 - 2628
  • [15] Cardiac Perfusion and Innervation Assessment by CZT-SPECT: Have a Look to Simultaneous Dual-isotope Protocol
    D'Antonio, Adriana
    Falzarano, Maria
    Reina, Fabrizio
    Assante, Roberta
    Zampella, Emilia
    Maio, Francesca
    Buongiorno, Pietro
    Panico, Mariarosaria
    Mainolfi, Ciro Gabriele
    Mannarino, Teresa
    Cuocolo, Alberto
    Acampa, Wanda
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2023, 16 (06) : 41 - 50
  • [16] 4D Mathematical Observer Models for the Task-Based Evaluation of Gated Myocardial Perfusion SPECT Images
    Lee, Taek-Soo
    Frey, Eric C.
    Tsui, Benjamin M. W.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2257 - 2260
  • [17] Compared vulnerabilities to small cardiac motions between different cameras used for myocardial perfusion imaging
    Salvadori, Julien
    Petegnief, Yolande
    Sabbah, Remi
    Morel, Olivier
    Boulahdour, Hatem
    Karcher, Gilles
    Marie, Pierre-Yves
    Imbert, Laetitia
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (04) : 1313 - 1322
  • [18] Quantification of myocardial uptake rate constants in dynamic small-animal SPECT using a cardiac phantom
    Johnson, Lindsay C.
    Guerraty, Marie A.
    Moore, Stephen C.
    Metzler, Scott D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06)
  • [19] Correction for respiration artefacts in myocardial perfusion SPECT is more effective when reconstructions supporting collimator detector response compensation are applied
    Kovalski, Gil
    Keidar, Zohar
    Frenkel, Alex
    Israel, Ora
    Azhari, Haim
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (06) : 949 - 955
  • [20] Simulation of Late Gadolinium Enhancement Cardiac Magnetic Resonance Studies
    Tobon-Gomez, C.
    Sukno, F. M.
    Butakoff, C.
    Huguet, M.
    Frangi, A. F.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1469 - 1472