Realistic Simulation of Regional Myocardial Perfusion Defects for Cardiac SPECT Studies

被引:0
|
作者
Fung, George S. K. [1 ]
Segars, W. Paul [2 ]
Lee, Taek-Soo [1 ]
Higuchi, Takahiro [1 ]
Veress, Alexander I. [3 ]
Gullberg, Grant T. [4 ]
Tsui, Benjamin M. W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21218 USA
[2] Duke Univ, Dept Radiol, Durham, NC USA
[3] Univ Washington, Dept Engn Mech, Seattle, WA USA
[4] Lawrence Berkeley Natl Lab, Berkeley, CA USA
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
PHANTOM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The current 3D XCAT phantom allows users to manually define the regional myocardial perfusion defect (MPD) as a simple pie-shaped wedge region with reduced activity level in the myocardium of left ventricle. To more accurately and realistically model the MPD, we have developed a new regional MPD model for the 3D XCAT phantom for myocardial perfusion SPECT (MP-SPECT) studies based on the location and the severity of the stenosis in a computer generated coronary arterial tree. First, we generated a detailed coronary arterial tree by extending the large proximal branches segmented from patient CT images to cover the whole heart using an iterative rule-based algorithm. Second, we determined the affected downstream vascular segments of a given stenosis. Third, we computed the activity of each myocardial region as a function of the inverse-distance-weighted average of the flow of the neighboring vascular segments. Fourth, we generated a series of bull's-eye maps of MP-SPECT images of different coronary artery stenosis scenarios. Fifth, we had expert physician readers to qualitatively assess the bull's-eye maps based on their similarity to typical clinical cases in terms of the shape, the extent, and the severity of the MPDs. Their input was used to iteratively revise the coronary artery tree model so that the MPDs were closely matched to those found in bull's-eye maps from patient studies. Finally, from our simulated MP-SPECT images, we observed that (1) the locations of the MPDs caused by stenoses at different main arteries were different largely according to their vascular territories, (2) a stenosis at a proximal branch produced a larger MPD than the one at a distal branch, and (3) a more severe stenosis produced a larger MPD than the less severe one. These observations were consistent to those found in clinical cases. Therefore, this new regional MPD model has enhanced the generation of realistic pathological MP-SPECT images using the XCAT phantom. When combining with the mechanical model of the myocardium, the new model can be extended for the simulation of 4D gated MP-SPECT simulation of a pathological heart with both perfusion and motion defects.
引用
收藏
页码:3061 / 3064
页数:4
相关论文
共 26 条
  • [1] The development and initial evaluation of a realistic simulated SPECT dataset with simultaneous respiratory and cardiac motion for gated myocardial perfusion SPECT
    Lee, Taek-Soo
    Tsui, Benjamin M. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04) : 1399 - 1413
  • [2] Evaluation of a cardiac flow phantom for absolute myocardial perfusion SPECT measurements
    Kamphuis, M. E.
    Greuter, Marcel J. W. J.
    Slart, Riemer J. H. A.
    Slump, Cornelis H.
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [3] Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT
    Daou, Doumit
    Sabbah, Remy
    Coaguila, Carlos
    Boulandour, Hatem
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (04) : 1299 - 1309
  • [4] Evaluation of Respiratory Motion Effect on Defect Detection in Myocardial Perfusion SPECT: A Simulation Study
    Yang, Yu-Wen
    Chen, Jyh-Cheng
    He, Xin
    Wang, Shyh-Jen
    Tsui, Benjamin M. W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 671 - 676
  • [5] Effect of respiratory motion on cardiac defect contrast in myocardial perfusion SPECT: a physical phantom study
    Kortelainen, Matti J.
    Koivumaki, Tuomas M.
    Vauhkonen, Marko J.
    Hakulinen, Mikko A.
    ANNALS OF NUCLEAR MEDICINE, 2019, 33 (05) : 305 - 316
  • [6] Effect of respiratory motion on cardiac defect contrast in myocardial perfusion SPECT: a physical phantom study
    Matti J. Kortelainen
    Tuomas M. Koivumäki
    Marko J. Vauhkonen
    Mikko A. Hakulinen
    Annals of Nuclear Medicine, 2019, 33 : 305 - 316
  • [7] Optimization of the filter parameters in 99mTc myocardial perfusion SPECT studies: the formulation of flowchart
    Shibutani, Takayuki
    Onoguchi, Masahisa
    Yamada, Tomoki
    Kamida, Hiroki
    Kunishita, Kohei
    Hayashi, Yuuki
    Nakajima, Tadashi
    Kinuya, Seigo
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (02) : 571 - 581
  • [8] Influence of respiratory motion correction on quantification of myocardial perfusion SPECT
    Bitarafan-Rajabi, Ahmad
    Rajabi, Hossein
    Rastgou, Feridoon
    Firoozabady, Hasan
    Yaghoobi, Nahid
    Malek, Hadi
    Langesteger, Werner
    Beheshti, Mohsen
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (05) : 1019 - 1030
  • [9] Has the era of dual-gated myocardial perfusion SPECT and PET arrived?
    Okuda, Koichi
    Nakajima, Kenichi
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (02) : 648 - 650
  • [10] A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom
    Otton, James
    Morton, Geraint
    Schuster, Andreas
    Bigalke, Boris
    Marano, Riccardo
    Olivotti, Luca
    Nagel, Eike
    Chiribiri, Amedeo