An Enhanced Fault-Ride-Through Capability of Doubly-Fed Induction Generators during Grid Faults

被引:0
作者
Azzouz, Maher A.
Elsaadany, Ehab F.
机构
来源
2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING | 2012年
关键词
Fault-ride-through; doubly-fed induction generator (DFIG); rotor current limiter (RCL); and demagnetizing rotor currents; WIND TURBINE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper discusses a new improved fault ride through technique of wind turbines equipped with doubly-fed induction generators (DFIG). The proposed technique replaces the conventional crowbar with a rotor current limiter (RCL) which is inserted to the rotor circuit upon grid faults detection. In additional to inserting a RCL, demagnetizing rotor currents are injected in order to reduce the induced high voltage appears on the rotor side converter. The proposed method allows the rotor side converter to stay connected to the system such that the DFIG can continue its normal operation immediately after the fault clearance. The simulation results show that the proposed technique limits the rotor inrush currents, DC voltage fluctuations, electromagnetic torque pulsations, and reactive power absorption during the fault and after the fault clearance.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] A New Converter Protection Scheme for Doubly-Fed Induction Generators during Disturbances
    Yang, Jin
    Dorrell, David G.
    Fletcher, John E.
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 2029 - +
  • [42] Low Voltage Ride-Through Control of Doubly-Fed Induction Generator at Synchronism
    Binh, N. V.
    Hofmann, W.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 803 - 809
  • [43] Active Disturbance Rejection Control of Doubly-Fed Induction Generators Driven by Wind Turbines
    Penne, Matthew
    Qiao, Wei
    Qu, Liyan
    Qu, Lizhi
    Huang, Renke
    Huang, Qiuhua
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 965 - 972
  • [44] Current-Limiting Droop Controller with Fault-Ride-Through Capability for Grid-Tied Inverters
    Paspatis, A. G.
    Konstantopoulos, G. C.
    Mayfield, M.
    Nikolaidis, V. C.
    2017 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2017,
  • [45] Application of the superconducting fault current limiter strategy to improve the fault ride-through capability of a doubly-fed induction generator-based wind energy conversion system
    Sitharthan, R.
    Geethanjali, M.
    SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2015, 91 (12): : 1081 - 1087
  • [46] Improved Demagnetization Control of a Doubly-Fed Induction Generator Under Balanced Grid Fault
    Zhou, Linyuan
    Liu, Jinjun
    Zhou, Sizhan
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (12) : 6695 - 6705
  • [47] A machine learning approach for active/reactive power control of grid-connected doubly-fed induction generators
    Tavoosi, Jafar
    Mohammadzadeh, Ardashir
    Pahlevanzadeh, Bahareh
    Kasmani, Morad Bagherzadeh
    Band, Shahab S.
    Safdar, Rabia
    Mosavi, Amir H.
    AIN SHAMS ENGINEERING JOURNAL, 2022, 13 (02)
  • [48] The fault ride through technologies for doubly fed induction generator wind turbines
    Ling, Yu
    WIND ENGINEERING, 2016, 40 (01) : 31 - 49
  • [49] A fault ride through scheme for doubly fed induction generator wind turbine
    Ling Y.
    Ling, Yu (pleasurely@126.com), 2018, Taylor and Francis Ltd. (15) : 71 - 79
  • [50] Improving Annual Energy Production of Doubly-Fed Induction Generators
    Wang, Xuezhou
    Liu, Dong
    Polinder, Henk
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (04) : 3405 - 3413