Reliability of microvascular responsiveness measures derived from near-infrared spectroscopy across a variety of ischemic periods in young and older individuals

被引:46
作者
Iannetta, Danilo [1 ]
Inglis, Erin Calaine [1 ]
Soares, Rogerio N. [1 ,2 ]
McLay, Kaitlin M. [1 ]
Pogliaghi, Silvia [2 ]
Murias, Juan M. [1 ]
机构
[1] Univ Calgary, Fac Kinesiol, Calgary, AB T2N 1N4, Canada
[2] Univ Verona, Dept Neurol & Movement Sci, Verona, Italy
基金
加拿大自然科学与工程研究理事会;
关键词
Test-to-test reliability; Day-to-day reliability; Oxygen saturation; Reactive hyperemia; Vasodilation; FLOW-MEDIATED DILATION; VASCULAR RESPONSIVENESS; ENDOTHELIAL DYSFUNCTION; NITRIC-OXIDE; REPRODUCIBILITY; ACETYLCHOLINE; VASODILATION; RESPONSES; CHILDREN; IMPROVES;
D O I
10.1016/j.mvr.2018.10.001
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Cardiovascular disease (CVD) is associated with impairments in microvascular responsiveness. Therefore, reliably assessing microvascular function is clinically relevant. Thus, this study aimed to examine the reliability of the near-infrared spectroscopy (NIRS)-derived oxygen saturation (StO(2)) reperfusion slope, a measure of microvascular responsiveness, to four different vascular occlusion tests (VOT) of different durations in young and older participants. Methods: Eight healthy young (29 +/- 5 yr) and seven older (67 +/- 4 yr) men participated in four NIRS combined with VOT (NIRS-VOT; 30 s, 1, 3, and 5 min) in the leg microvasculature on two visits separated by 1-2 weeks. Vascular responsiveness was determined by the StO(2) reperfusion slope. The coefficient of variation (CV), repeatability, reliability (ICC), and the limits of agreement (LOA) were calculated for the NIRS-derived reperfusion slopes for each occlusion duration and visit. Results: CV for the StO(2) reperfusion slope following 30 s, 1, 3 and 5 min of occlusion were 33 +/- 29%, 19 +/- 21%, 14 +/- 12%, and 12 +/- 10%, respectively. Repeatability values following 30 s, 1, 3 and 5 min occlusions were 20%, 1%, 4% and 21%, respectively. The ICC for the St0 2 reperfusion slopes for each occlusion duration were 0.29, 0.42, 0.84, and 0.88 following 30 s, 1, 3 and 5 min of occlusion, respectively. LOA values between visit 1 and 2 for occlusions were not different from zero. There were no age-related differences for all variables of the study. Conclusion: NIBS-derived StO(2) reperfusion slope, has good reliability across a range of occlusion durations with the strongest reliability during longer occlusion durations.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 36 条
  • [1] Measurement error
    Bland, JM
    Altman, DG
    [J]. BRITISH MEDICAL JOURNAL, 1996, 312 (7047) : 1654 - 1654
  • [2] Endothelial-derived hyperpolarization contributes to acetylcholine-mediated vasodilation in human skin in a dose-dependent manner
    Brunt, Vienna E.
    Fujii, Naoto
    Minson, Christopher T.
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2015, 119 (09) : 1015 - 1022
  • [3] NONINVASIVE DETECTION OF ENDOTHELIAL DYSFUNCTION IN CHILDREN AND ADULTS AT RISK OF ATHEROSCLEROSIS
    CELERMAJER, DS
    SORENSEN, KE
    GOOCH, VM
    SPIEGELHALTER, DJ
    MILLER, OI
    SULLIVAN, ID
    LLOYD, JK
    DEANFIELD, JE
    [J]. LANCET, 1992, 340 (8828) : 1111 - 1115
  • [4] Flow-Mediated Dilation Is Acutely Improved after High-Intensity Interval Exercise
    Currie, Katharine Dianne
    McKelvie, Robert S.
    MacDonald, Maureen J.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (11) : 2057 - 2064
  • [5] Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia
    Davies, David James
    Clancy, Michael
    Lighter, Daniel
    Balanos, George M.
    Lucas, Samuel John Edwin
    Dehghani, Hamid
    Su, Zhangjie
    Forcione, Mario
    Belli, Antonio
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 967 - 974
  • [6] IMPAIRED ENDOTHELIUM-DEPENDENT VASODILATION OF LARGE EPICARDIAL AND RESISTANCE CORONARY-ARTERIES IN PATIENTS WITH ESSENTIAL-HYPERTENSION - DIFFERENT RESPONSES TO ACETYLCHOLINE AND SUBSTANCE-P
    EGASHIRA, K
    SUZUKI, S
    HIROOKA, Y
    KAI, H
    SUGIMACHI, M
    IMAIZUMI, T
    TAKESHITA, A
    [J]. HYPERTENSION, 1995, 25 (02) : 201 - 206
  • [7] Fitness Level and Not Aging per se, Determines the Oxygen Uptake Kinetics Response
    George, Mitchell A.
    McLay, Kaitlin M.
    Doyle-Baker, Patricia K.
    Reimer, Raylene A.
    Murias, Juan M.
    [J]. FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [8] Utilizing the vascular occlusion technique with NIRS technology
    Gerovasili, Vasiliki
    Dimopoulos, Stavros
    Tzanis, Georgios
    Anastasiou-Nana, Maria
    Nanas, Serafeim
    [J]. INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2010, 40 (02) : 218 - 222
  • [9] Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O2 saturation response
    Gomez, Hernando
    Torres, Andres
    Polanco, Patricio
    Kim, Hyung Kook
    Zenker, Sven
    Puyana, Juan Carlos
    Pinsky, Michael R.
    [J]. INTENSIVE CARE MEDICINE, 2008, 34 (09) : 1600 - 1607
  • [10] Relationship between changes in brachial artery flow-mediated dilation and basal release of nitric oxide in subjects with Type 2 diabetes
    Green, Daniel J.
    Maiorana, Andrew J.
    Tschakovsky, Michael E.
    Pyke, Kyra E.
    Weisbrod, Cara J.
    O'Driscoll, Gerry
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 291 (03): : H1193 - H1199