Reliability of microvascular responsiveness measures derived from near-infrared spectroscopy across a variety of ischemic periods in young and older individuals

被引:48
作者
Iannetta, Danilo [1 ]
Inglis, Erin Calaine [1 ]
Soares, Rogerio N. [1 ,2 ]
McLay, Kaitlin M. [1 ]
Pogliaghi, Silvia [2 ]
Murias, Juan M. [1 ]
机构
[1] Univ Calgary, Fac Kinesiol, Calgary, AB T2N 1N4, Canada
[2] Univ Verona, Dept Neurol & Movement Sci, Verona, Italy
基金
加拿大自然科学与工程研究理事会;
关键词
Test-to-test reliability; Day-to-day reliability; Oxygen saturation; Reactive hyperemia; Vasodilation; FLOW-MEDIATED DILATION; VASCULAR RESPONSIVENESS; ENDOTHELIAL DYSFUNCTION; NITRIC-OXIDE; REPRODUCIBILITY; ACETYLCHOLINE; VASODILATION; RESPONSES; CHILDREN; IMPROVES;
D O I
10.1016/j.mvr.2018.10.001
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: Cardiovascular disease (CVD) is associated with impairments in microvascular responsiveness. Therefore, reliably assessing microvascular function is clinically relevant. Thus, this study aimed to examine the reliability of the near-infrared spectroscopy (NIRS)-derived oxygen saturation (StO(2)) reperfusion slope, a measure of microvascular responsiveness, to four different vascular occlusion tests (VOT) of different durations in young and older participants. Methods: Eight healthy young (29 +/- 5 yr) and seven older (67 +/- 4 yr) men participated in four NIRS combined with VOT (NIRS-VOT; 30 s, 1, 3, and 5 min) in the leg microvasculature on two visits separated by 1-2 weeks. Vascular responsiveness was determined by the StO(2) reperfusion slope. The coefficient of variation (CV), repeatability, reliability (ICC), and the limits of agreement (LOA) were calculated for the NIRS-derived reperfusion slopes for each occlusion duration and visit. Results: CV for the StO(2) reperfusion slope following 30 s, 1, 3 and 5 min of occlusion were 33 +/- 29%, 19 +/- 21%, 14 +/- 12%, and 12 +/- 10%, respectively. Repeatability values following 30 s, 1, 3 and 5 min occlusions were 20%, 1%, 4% and 21%, respectively. The ICC for the St0 2 reperfusion slopes for each occlusion duration were 0.29, 0.42, 0.84, and 0.88 following 30 s, 1, 3 and 5 min of occlusion, respectively. LOA values between visit 1 and 2 for occlusions were not different from zero. There were no age-related differences for all variables of the study. Conclusion: NIBS-derived StO(2) reperfusion slope, has good reliability across a range of occlusion durations with the strongest reliability during longer occlusion durations.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 36 条
[1]   Measurement error [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 312 (7047) :1654-1654
[2]   Endothelial-derived hyperpolarization contributes to acetylcholine-mediated vasodilation in human skin in a dose-dependent manner [J].
Brunt, Vienna E. ;
Fujii, Naoto ;
Minson, Christopher T. .
JOURNAL OF APPLIED PHYSIOLOGY, 2015, 119 (09) :1015-1022
[3]   NONINVASIVE DETECTION OF ENDOTHELIAL DYSFUNCTION IN CHILDREN AND ADULTS AT RISK OF ATHEROSCLEROSIS [J].
CELERMAJER, DS ;
SORENSEN, KE ;
GOOCH, VM ;
SPIEGELHALTER, DJ ;
MILLER, OI ;
SULLIVAN, ID ;
LLOYD, JK ;
DEANFIELD, JE .
LANCET, 1992, 340 (8828) :1111-1115
[4]   Flow-Mediated Dilation Is Acutely Improved after High-Intensity Interval Exercise [J].
Currie, Katharine Dianne ;
McKelvie, Robert S. ;
MacDonald, Maureen J. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (11) :2057-2064
[5]   Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia [J].
Davies, David James ;
Clancy, Michael ;
Lighter, Daniel ;
Balanos, George M. ;
Lucas, Samuel John Edwin ;
Dehghani, Hamid ;
Su, Zhangjie ;
Forcione, Mario ;
Belli, Antonio .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) :967-974
[6]   IMPAIRED ENDOTHELIUM-DEPENDENT VASODILATION OF LARGE EPICARDIAL AND RESISTANCE CORONARY-ARTERIES IN PATIENTS WITH ESSENTIAL-HYPERTENSION - DIFFERENT RESPONSES TO ACETYLCHOLINE AND SUBSTANCE-P [J].
EGASHIRA, K ;
SUZUKI, S ;
HIROOKA, Y ;
KAI, H ;
SUGIMACHI, M ;
IMAIZUMI, T ;
TAKESHITA, A .
HYPERTENSION, 1995, 25 (02) :201-206
[7]   Fitness Level and Not Aging per se, Determines the Oxygen Uptake Kinetics Response [J].
George, Mitchell A. ;
McLay, Kaitlin M. ;
Doyle-Baker, Patricia K. ;
Reimer, Raylene A. ;
Murias, Juan M. .
FRONTIERS IN PHYSIOLOGY, 2018, 9
[8]   Utilizing the vascular occlusion technique with NIRS technology [J].
Gerovasili, Vasiliki ;
Dimopoulos, Stavros ;
Tzanis, Georgios ;
Anastasiou-Nana, Maria ;
Nanas, Serafeim .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2010, 40 (02) :218-222
[9]   Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O2 saturation response [J].
Gomez, Hernando ;
Torres, Andres ;
Polanco, Patricio ;
Kim, Hyung Kook ;
Zenker, Sven ;
Puyana, Juan Carlos ;
Pinsky, Michael R. .
INTENSIVE CARE MEDICINE, 2008, 34 (09) :1600-1607
[10]   Relationship between changes in brachial artery flow-mediated dilation and basal release of nitric oxide in subjects with Type 2 diabetes [J].
Green, Daniel J. ;
Maiorana, Andrew J. ;
Tschakovsky, Michael E. ;
Pyke, Kyra E. ;
Weisbrod, Cara J. ;
O'Driscoll, Gerry .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 291 (03) :H1193-H1199