Validation of an online dual-loop cleanup device with an electrospray ionization tandem mass spectrometry-based system for simultaneous quantitative analysis of urinary benzene exposure biomarkers trans, trans-muconic acid and S-phenylmercapturic acid

被引:14
|
作者
Lin, LC
Chiung, YM
Shih, JF
Shih, TS
Liao, PC
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Environm & Occupat Hlth, Tainan 704, Taiwan
[2] Inst Occupat Safety & Hlth, Div Method Dev & Anal, Shijr City 221, Taipei, Taiwan
[3] Natl Def Med Ctr, Dept Microbiol & Immunol, Taipei 114, Taiwan
关键词
benzene; urine; trans; trans-muconic acid; S-phenylmercapturic acid; electrospray ionization tandem mass spectrometry;
D O I
10.1016/j.aca.2005.08.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study is to validate isotope-dilution electrospray ionization tandem mass spectrometry (ESI-MS-MS) method with a dual-loop cleanup device for simultaneous quantitation of two benzene metabolites, trans, trans-muconic acid (ttMA) and S-phenylmercapturic acid (SPMA), in human urine. In this study, a pooled blank urine matrix from rural residents was adopted for validation of the analytical method. The calibration curve, detection limit, recovery, precision, accuracy and the stability of sample storage for the system have been characterized. Calibration plots of ttMA and SPMA standards spiked into two kinds of urine matrixes over a wide concentration range, 1/32-8-fold biological exposure indices (BEIs) values, showed good linearity (R > 0.9992). The detection limits in pooled urine matrix for ttMA and SPMA were 1.27 and 0.042 mu g g(-1) creatinine, respectively. For both of ttMA and SPMA, the intra- and inter-day precision values were considered acceptable well below 25% at the various spiked concentrations. The intra- and inter-day apparent recovery values were also considered acceptable (apparent recovery > 90%). The ttMA accuracy was estimated by urinary standard reference material (SRM). The accuracy reported in terms of relative error (RE) was 5.0 +/- 2.0% (n = 3). The stability of sample storage at 4 or -20 degrees C were assessed. Urinary ttMA and SPMA were found to be stable for at least 8 weeks when stored at 4 or -20 degrees C. In addition, urine samples from different benzene exposure groups were collected and measured in this system. Without tedious manual sample preparation procedure, the analytical system was able to quantify simultaneously ttMA and SPMA in less than 20 min. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 3 条
  • [1] Personal exposure to different levels of benzene and its relationships to the urinary metabolites S-phenylmercapturic acid and trans,trans-muconic acid
    Melikian, AA
    Qu, QS
    Shore, R
    Li, GL
    Li, HY
    Jin, XM
    Cohen, B
    Chen, LC
    Li, YY
    Yin, SN
    Mu, RD
    Zhang, XL
    Wang, YX
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2): : 211 - 221
  • [2] Urinary trans, trans-muconic acid and S-phenylmercapturic acid are indicative of exposure to urban benzene pollution during childhood
    Protano, Carmela
    Andreoli, Roberta
    Manini, Paola
    Vitali, Matteo
    SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 435 : 115 - 123
  • [3] Method development for the simultaneous analysis of trans,trans-muconic acid, 1,2-dihydroxybenzene, S-phenylmercapturic acid and S-benzylmercapturic acid in human urine by liquid chromatography/tandem mass spectrometry
    Fan, Ruifang
    Wang, Dongli
    She, Jianwen
    ANALYTICAL METHODS, 2015, 7 (02) : 573 - 580