Intraperitoneal pressure in peritoneal dialysis

被引:30
作者
Perez Diaz, Vicente [1 ,2 ]
Sanz Ballesteros, Sandra [1 ]
Hernandez Garcia, Esther [3 ]
Descalzo Casado, Elena [4 ]
Herguedas Callejo, Irene [4 ]
Ferrer Perales, Cristina [1 ]
机构
[1] Hosp Clin Univ Valladolid, Serv Nefrol, Valladolid, Spain
[2] Univ Valladolid, Fac Med, Dept Med Dermatol & Toxicol, Valladolid, Spain
[3] Complejo Asistencial Univ Palencia, Serv Nefrol, Palencia, Spain
[4] Univ Valladolid, Fac Med, Valladolid, Spain
来源
NEFROLOGIA | 2017年 / 37卷 / 06期
关键词
Intraperitoneal pressure; Hydrostatic pressure; Ultrafiltration; Ultrafiltration failure; Mechanical complications of; peritoneal dialysis; Infusion volume; FILL-VOLUME; ULTRAFILTRATION FAILURE; SOLUTE TRANSPORT; BODY-SIZE; CHILDREN; FLUID; IMPACT; CAPD; COMPLICATIONS; TOLERANCE;
D O I
10.1016/j.nefro.2017.05.014
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
The measure of intraperitoneal pressure in peritoneal dialysis is easy and provides clear therapeutic benefits. However it is measured only rarely in adult peritoneal dialysis units. This review aims to disseminate the usefulness of measuring intraperitoneal pressure. This measurement is performed in supine before initiating the drain of a manual exchange with "Y" system, by raising the drain bag and measuring from the mid-axillary line the height of the liquid column that rises from the patient. With typical values of 10-16 cm H2O, intraperitoneal pressure should never exceed 18 cm H2O. With basal values that depend on body mass index, it increases 1-3 cm H2O/L of intraperitoneal volume, and varies with posture and physical activity. Its increase causes discomfort, sleep and breathing disturbances, and has been linked to the occurrence of leaks, hernias, hydrothorax, gastro-esophageal reflux and enteric peritonitis. Less known and valued is its ability to decrease the effectiveness of dialysis significantly counteracting ultrafiltration and decreasing solute clearance to a smaller degree. Because of its easy measurement and potential utility, should be monitored in case of ultrafiltration failure to rule out its eventual contribution in some patients. Although not yet mentioned in the clinical practice guidelines for PD, its clear benefits justify its inclusion among the periodic measurements to consider for prescribing and monitoring peritoneal dialysis. (c) 2017 Sociedad Espanola de Nefrologia. Published by Elsevier Espana,S.L.U.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 57 条
  • [1] ABENSUR H, 1993, ADV PERIT D, V9, P41
  • [2] Intraperitoneal pressure and hernias in children on peritoneal dialysis
    Aranda, RA
    Romao, JE
    Kakehashi, E
    Domingos, W
    Sabbaga, E
    Marcondes, M
    Abensur, H
    [J]. PEDIATRIC NEPHROLOGY, 2000, 14 (01) : 22 - 24
  • [3] CLINICAL RELEVANCE OF INTRAPERITONEAL PRESSURE IN PERITONEAL DIALYSIS PATIENTS
    Betancourt Castellanos, Loreley
    Ponz Clemente, Esther
    Blasco Cabanas, Conchita
    Marquina Parra, Dolors
    Bolos Contador, Mabel
    Oliva Morera, Juan Carlos
    Almirall Daly, Jaume
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2017, 37 (05): : 562 - 567
  • [4] Blasco Cabanas C, 2012, ENFERM NEFROL, V15, P94
  • [5] Boudville N, 2015, HDB DIALYSIS, P483
  • [6] RELATIONSHIP BETWEEN DRAIN VOLUME/FILL VOLUME RATIO AND CLINICAL OUTCOMES ASSOCIATED WITH OVERFILL COMPLAINTS IN PERITONEAL DIALYSIS PATIENTS
    Davis, Ira D.
    Cizman, Borut
    Mundt, Kelly
    Wu, LieLing
    Childers, Robert
    Mell, Rod
    Prichard, Sarah
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2011, 31 (02): : 148 - 153
  • [7] Intraperitoneal pressure in PD patients: relationship to intraperitoneal volume, body size and PD-related complications
    Dejardin, Agnes
    Robert, Annie
    Goffin, Eric
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (05) : 1437 - 1444
  • [8] Del Peso G, 2003, PERITON DIALYSIS INT, V23, P249
  • [9] Durand P Y, 1994, Adv Perit Dial, V10, P63
  • [10] DURAND PY, 1992, ADV PERIT D, V8, P22