A Monte Carlo study of an energy-weighted algorithm for radionuclide analysis with a plastic scintillation detector

被引:15
|
作者
Shin, Wook-Geun [1 ]
Lee, Hyun-Cheol [1 ]
Choi, Chang-Il [2 ]
Park, Chang Soo [2 ]
Kim, Hong-Suk [2 ]
Min, Chul Hee [1 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Seoul 120749, South Korea
[2] Korea Inst Nucl Safety, Radiol Emergency & Secur Preparedness Dept, Taejon, South Korea
基金
新加坡国家研究基金会;
关键词
Monte Carlo simulation; Plastic scintillator; Energy-weighted algorithm; Radionuclide analysis; Radiation portal monitor; RADIATION PORTAL MONITORS; CALIBRATION;
D O I
10.1016/j.apradiso.2015.03.014
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Nuisance and false alarms due to naturally occurring radioactive material (NORM) are major problems facing radiation portal monitors (RPMs) for the screening of illicit radioactive materials in airports and ports. Based on energy-weighted counts, we suggest an algorithm that distinguishes radioactive nuclides with a plastic scintillation detector that has poor energy resolution. Our simulation study, using a Monte Carlo method, demonstrated that man-made radionuclides can be separated from NORM by using a conventional RPM. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [1] Validation of energy-weighted algorithm for radiation portal monitor using plastic scintillator
    Lee, Hyun Cheol
    Shin, Wook-Geun
    Park, Hyo Jun
    Yoo, Do Hyun
    Choi, Chang-Il
    Park, Chang-Su
    Kim, Hong-Suk
    Min, Chul Hee
    APPLIED RADIATION AND ISOTOPES, 2016, 107 : 160 - 164
  • [2] Radionuclide identification based on energy-weighted algorithm and machine learning applied to a multi-array plastic scintillator
    Lee, Hyun Cheol
    Koo, Bon Tack
    Jeon, Ju Young
    Cheon, Bo-Wi
    Yoo, Do Hyeon
    Chung, Heejun
    Min, Chul Hee
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (10) : 3907 - 3912
  • [3] Iterative Monte Carlo simulation with the Compton kinematics-based GEB in a plastic scintillation detector
    Kim, Chankyu
    Kim, Yewon
    Moon, Myungkook
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 298 - 304
  • [4] Radioisotope identification using an energy-weighted algorithm with a proof-of-principle radiation portal monitor based on plastic scintillators
    Lee, Hyun Cheol
    Shin, Wook-geun
    Choi, Hyun Joon
    Choi, Chang-Il
    Park, Chang Su
    Kim, Hong-Suk
    Min, Chul Hee
    APPLIED RADIATION AND ISOTOPES, 2020, 156 (156)
  • [5] Dynamic radionuclide identification using energy weighted algorithm with commercialized radiation portal monitor based on plastic scintillators
    Lee, Hyun Cheol
    Choi, Hyun Joon
    Koo, Bon Tack
    Choi, Chang-Il
    Park, Chang Su
    Kim, Hong-Suk
    Min, Chul Hee
    RADIATION PHYSICS AND CHEMISTRY, 2020, 170
  • [6] Characterisation of a radionuclide specific laboratory detector system for the metallurgical industry by Monte Carlo simulations
    Solc, Jaroslav
    Dryak, Pavel
    Moser, Hannah
    Branger, Thierry
    Garcia-Torano, Eduardo
    Peyres, Virginia
    Tzika, Faidra
    Lutter, Guillaume
    Capogni, Marco
    Fazio, Aldo
    Luca, Aurelian
    Vodenik, Branko
    Oliveira, Carlos
    Saraiva, Andre
    Szucs, Laszlo
    Dziel, Tomasz
    Burda, Oleksiy
    Arnold, Dirk
    Martinkovic, Jozef
    Siiskonen, Teemu
    Mattila, Aleksi
    RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 189 - 193
  • [7] Monte Carlo simulation of the full energy peak efficiency of an HPGe detector
    Khan, Waseem
    Zhang, Qingmin
    He, Chaohui
    Saleh, Muhammad
    APPLIED RADIATION AND ISOTOPES, 2018, 131 : 67 - 70
  • [8] Primary study of Monte Carlo simulation on CdZnTe nuclear detector
    Ren, SJ
    Sang, WB
    Jin, W
    Li, WW
    Zhang, Q
    Min, JH
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (02): : 191 - 195
  • [9] A Monte Carlo study on 223Ra imaging for unsealed radionuclide therapy
    Takahashi, Akihiko
    Miwa, Kenta
    Sasaki, Masayuki
    Baba, Shingo
    MEDICAL PHYSICS, 2016, 43 (06) : 2965 - 2974
  • [10] Study of the response of an ORTEC GMX45 HPGe detector with a multi-radionuclide volume source using Monte Carlo simulations
    Saraiva, A.
    Oliveira, C.
    Reis, M.
    Portugal, L.
    Paiva, I.
    Cruz, C.
    APPLIED RADIATION AND ISOTOPES, 2016, 113 : 47 - 52