Whole-body MRA

被引:16
作者
Kramer, Harald [1 ]
Quick, Harald H. [2 ]
Tombach, Bernd [3 ,4 ]
Schoenberg, Stefan O. [5 ]
Barkhausen, Joerg [2 ]
机构
[1] Univ Munich, Univ Hosp Munich, Inst Clin Radiol, D-81377 Munich, Germany
[2] Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, D-45122 Essen, Germany
[3] Univ Munster, Dept Clin Radiol, Munster, Germany
[4] Klinikum Osnabruck Rontgen & Strahlenklin, Osnabruck, Germany
[5] Univ Heidelberg, Med Fac Mannheim, Univ Hosp Mannheim, Dept Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
关键词
MRI; MRA; whole-body imaging; whole-body MRA; atherosclerosis;
D O I
10.1007/s00330-007-0817-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Vascular diseases today constitute a serious health burden, ranking atherosclerosis as number one in the morbidity and mortality statistics of developed countries, with a still-growing incidence. Different treatment options are available for all vascular territories, ranging from conservative pharmacological treatment and catheter-based interventions up to surgical methods with remodelling of the vessels or bypass implantation. For treatment planning, all listed procedures have in common that they rely on initial diagnostic imaging to assess the degree and extent of stenoses. In this respect, imaging of the arterial system from the head down to the feet seems to be reasonable. Up to now no imaging technique allowed the assessment of the complete arterial system in only one exam within a reasonable time and without limiting factors like invasiveness and ionizing radiation. However, recent developments in magnetic resonance (MR) hardware and software, such as dedicated whole-body MR systems with specially designed surface coils, the movement to higher field strength and the implementation of parallel acquisition techniques (PAT), have helped to overcome the long-standing limitations of MR angiography (MRA), like reduced spatial resolution, long acquisition time, the restriction to body parts and only one field of view of a maximum 50 cm.
引用
收藏
页码:1925 / 1936
页数:12
相关论文
共 72 条
[1]   Detection of presymptomatic atherosclerosis: a current perspective [J].
Adams, MR ;
Celermajer, DS .
CLINICAL SCIENCE, 1999, 97 (05) :615-624
[2]   Management of peripheral vascular disease [J].
Baumgartner, I ;
Schainfeld, R ;
Graziani, L .
ANNUAL REVIEW OF MEDICINE, 2005, 56 :249-272
[3]   MR angiography with venous compression [J].
Bilecen, D ;
Schulte, AC ;
Aschwanden, M ;
Jaeger, K ;
Bongartz, G .
RADIOLOGY, 2004, 233 (02) :617-618
[4]   Sensitivity encoding (SENSE) for contrast enhanced 3D MR angiography of the abdominal arteries [J].
Born, M ;
Willinek, WA ;
Gieseke, J ;
von Falkenhausen, M ;
Schild, H ;
Kuhl, CK .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (04) :559-565
[5]   MR angiography of the lower extremity arteries with an automated table-moving technique ("MobiTrak") - Clinical experience in 450 examinations. [J].
Busch, HP ;
Hoffmann, HG ;
Rock, J ;
Schneider, C .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (05) :405-409
[6]   The prevalence of carotid artery stenosis in patients undergoing aortic reconstruction [J].
Cahan, MA ;
Killewich, LA ;
Kolodner, L ;
Powell, CC ;
Metz, M ;
Sawyer, R ;
Lilly, MP ;
Benjamin, ME ;
Flinn, WR .
AMERICAN JOURNAL OF SURGERY, 1999, 178 (03) :194-196
[7]   Carotid bifurcation: Evaluation of time-resolved three-dimensional contrast-enhanced MR angiography [J].
Carroll, TJ ;
Korosec, FR ;
Petermann, GM ;
Grist, TM ;
Turski, PA .
RADIOLOGY, 2001, 220 (02) :525-532
[8]   MR angiography of tibial runoff vessels: Imaging with the head coil compared with conventional arteriography [J].
Cortell, ED ;
Kaufman, JA ;
Geller, SC ;
Cambria, RP ;
Rivitz, SM ;
Waltman, AC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :147-151
[9]   Epidemiology of peripheral arterial disease [J].
Diehm, C ;
Kareem, S ;
Lawall, H .
VASA-JOURNAL OF VASCULAR DISEASES, 2004, 33 (04) :183-189
[10]  
Dormandy J, 1999, Semin Vasc Surg, V12, P118