Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners

被引:52
作者
DiFilippo, Frank P. [1 ]
机构
[1] Cleveland Clin, Dept Nucl Med, Cleveland, OH 44195 USA
关键词
D O I
10.1088/0031-9155/53/15/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A multi-pinhole collimation device is developed that uses the gamma camera detectors of a clinical SPECT or SPECT-CT scanner to produce high-resolution SPECT images. The device consists of a rotating cylindrical collimator having 22 tungsten pinholes with 0.9 mm diameter apertures and an animal bed inside the collimator that moves linearly to provide helical or ordered-subsets axial sampling. CT images also may be acquired on a SPECT-CT scanner for purposes of image co-registration and SPECT attenuation correction. The device is placed on the patient table of the scanner without attaching to the detectors or scanner gantry. The system geometry is calibrated in-place from point source data and is then used during image reconstruction. The SPECT imaging performance of the device is evaluated with test phantom scans. Spatial resolution from reconstructed point source images is measured to be 0.6 mm full width at half maximum or better. Micro-Derenzo phantom images demonstrate the ability to resolve 0.7 mm diameter rod patterns. The axial slabs of a Micro-Defrise phantom are visualized well. Collimator efficiency exceeds 0.05% at the center of the field of view, and images of a uniform phantom show acceptable uniformity and minimal artifact. The overall simplicity and relatively good imaging performance of the device make it an interesting low-cost alternative to dedicated small animal scanners.
引用
收藏
页码:4185 / 4201
页数:17
相关论文
共 29 条
[1]   Detectors for small-animal SPECT I - Overview of technologies [J].
Barrett, HH ;
Hunter, WCJ .
SMALL ANIMAL SPECT IMAGING, 2005, :9-48
[2]  
Beekman FJ, 2005, J NUCL MED, V46, P1194
[3]   Multi-modality imaging on track [J].
Beekman, Freek ;
Hutton, Brian F. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (09) :1410-1414
[4]  
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
[5]   Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging - a simulation study [J].
Cao, ZX ;
Bal, G ;
Accorsi, R ;
Acton, PD .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4609-4624
[6]   Image reconstruction [J].
Defrise, Michel ;
Gullberg, Grant T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) :R139-R154
[7]  
DiFilippo FP, 2006, IEEE NUCL SCI CONF R, P1842
[8]   Geometric characterization of multi-axis multi-pinhole SPECT [J].
DiFilippo, Frank P. .
MEDICAL PHYSICS, 2008, 35 (01) :181-194
[9]   Detached multipinhole small animal SPECT device with real-time calibration [J].
DiFilippo, Frank P. ;
Riffe, Matthew J. ;
Harsch, Kelley M. ;
McCabe, N. Patrick ;
Heston, Warren D. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) :2605-2612
[10]   CODED APERTURE IMAGING WITH UNIFORMLY REDUNDANT ARRAYS [J].
FENIMORE, EE ;
CANNON, TM .
APPLIED OPTICS, 1978, 17 (03) :337-347