Utilization of Thoracic Ultrasound for Confirmation of Central Venous Catheter Placement and Exclusion of Pneumothorax: A Novel Technique in Real-Time Application

被引:14
作者
Raman, Dileep [1 ]
Sharma, Manish [1 ]
Moghekar, Ajit [1 ]
Wang, Xiaofeng [2 ]
Hatipoglu, Umur [1 ]
机构
[1] Cleveland Clin, Resp Inst, Cleveland, OH 44106 USA
[2] Cleveland Clin, Quantitat Hlth Sci, Cleveland, OH 44106 USA
关键词
central venous catheter; ultrasound; chest radiograph; portable chest X-ray; VEIN CATHETER; SALINE FLUSH;
D O I
10.1177/0885066617705839
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim: To evaluate the safety and utility of ultrasonography as a tool to confirm central venous catheter (CVC) position and to exclude insertion-related pneumothorax in place of chest radiography (CXR) in a tertiary medical intensive care unit (ICU). Methods: We randomized 60 consecutive medical ICU patients to conventional or ultrasound groups for CVC placement. Both groups had CVCs inserted under ultrasound guidance. The intervention group underwent real-time transthoracic echocardiography to assist in catheter positioning and chest ultrasonography for exclusion of pneumothorax. Our primary end point was reduction in CXR use. The secondary end point was time elapsed from the end of procedure to the availability of CVC for use. chi(2) test was used to compare the 2 groups for the primary end point. T test was used to compare the 2 groups for the secondary end point. Results: Thirty patients were randomized to the conventional group and 30 were randomized to the ultrasound group. One patient was excluded in the control group since the procedure needed to be aborted. Patient characteristics were well matched for age, body mass index, and acute physiologic assessment and chronic health evaluation (APACHE III) scores. There was a 56.7% (P < .0001) reduction in CXR use in the ultrasound arm. Mean time to use was 53.6 minutes in the control group and 25 minutes in the ultrasound arm (P = .0015). Mean time required to complete the procedure was 27.7 minutes in the control group and 24.1 minutes in the ultrasound group (P = .2053). No pneumothorax was detected in either arm. Conclusion: Ultrasound-guided CVC placement and positioning with a minor modification in technique reduced the use of bedside CXR and reduced the time to use of the CVC.
引用
收藏
页码:594 / 598
页数:5
相关论文
共 13 条
[1]   Transesophageal Echocardiography for Verification of the Position of the Electrocardiographically-Placed Central Venous Catheter [J].
Ender, Joerg ;
Erdoes, Gabor ;
Krohmer, Eugen ;
Olthoff, Derk ;
Mukherjee, Chirojit .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (04) :457-461
[2]   Value of ultrasound in diagnosis of pneumothorax: A prospective study [J].
Jalli R. ;
Sefidbakht S. ;
Jafari S.H. .
Emergency Radiology, 2013, 20 (2) :131-134
[3]   The comet-tail artifact:: an ultrasound sign ruling out pneumothorax [J].
Lichtenstein, D ;
Mezière, G ;
Biderman, P ;
Gepner, A .
INTENSIVE CARE MEDICINE, 1999, 25 (04) :383-388
[4]   A BEDSIDE ULTRASOUND SIGN RULING OUT PNEUMOTHORAX IN THE CRITICALLY ILL - LUNG SLIDING [J].
LICHTENSTEIN, DA ;
MENU, Y .
CHEST, 1995, 108 (05) :1345-1348
[5]   Bedside Ultrasound can Safely Eliminate the Need for Chest Radiographs after Central Venous Catheter Placement: CVC Sono in the Surgical ICU (SICU) [J].
Matsushima, Kazuhide ;
Frankel, Heidi L. .
JOURNAL OF SURGICAL RESEARCH, 2010, 163 (01) :155-161
[6]   Ultrasonic examination - An alternative to chest radiography after central venous catheter insertion? [J].
Maury, E ;
Guglielminotti, J ;
Alzieu, M ;
Guidet, B ;
Offenstadt, G .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (03) :403-405
[7]   Accurate placement of central venous catheters in pediatric patients using endocavitary electrocardiography: Reassessment of a personal technique [J].
Parigi, GB ;
Verga, G .
JOURNAL OF PEDIATRIC SURGERY, 1997, 32 (08) :1226-1228
[8]   Saline flush test for bedside detection of misplaced subclavian vein catheter into ipsilateral internal jugular vein [J].
Rath, G. P. ;
Bithal, P. K. ;
Toshniwal, G. R. ;
Prabhakar, H. ;
Dash, H. H. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (04) :499-502
[9]   Accuracy of transthoracic sonography in detection of pneumothorax after sonographically guided lung biopsy: Prospective comparison with chest radiography [J].
Sartori, Sergio ;
Tombesi, Paola ;
Trevisani, Lucio ;
Nielsen, Ingrid ;
Tassinari, Davide ;
Abbasciano, Vincenzo .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) :37-41
[10]   Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: An alternative to chest radiography [J].
Vezzani, Antonella ;
Brusasco, Claudia ;
Palermo, Salvatore ;
Launo, Claudio ;
Mergoni, Mario ;
Corradi, Francesco .
CRITICAL CARE MEDICINE, 2010, 38 (02) :533-538