摘要
The feasibility of using a focused ion beam (FIB) for the purpose of thinning vitreously frozen biological specimens for transmission electron microscopy (TEM) was explored. A concern was whether heat transfer beyond the direct ion interaction layer might devitrify the ice. To test this possibility, we milled vitreously frozen water on a standard TEM grid with a 30-keV Ga+ beam, and cryo-transferred the grid to a TEM for examination. Following FIB milling of the vitreous ice from a thickness of approximately 1200 nm to 200-150 nm, changes characteristic of heat-induced devitrification were not observed by TEM, in either images or diffraction patterns. Although numerous technical challenges remain, it is anticipated that 'cryo-FIB thinning' of bulk frozen-hydratred material will be capable of producing specimens for TEM cryo-tomography with much greater efficiency than cryo-ultramicrotomy, and without the specimen distortions and handling difficulties of the latter.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 22 条
  • [11] LEIS A, 2005, MICROSC MICROANAL S2, V11, pCD330
  • [12] Electron backscattering diffraction investigation of focused ion beam surfaces
    Matteson, TL
    Schwarz, SW
    Houge, EC
    Kempshall, BW
    Giannuzzi, LA
    [J]. JOURNAL OF ELECTRONIC MATERIALS, 2002, 31 (01) : 33 - 39
  • [13] CRYOSECTIONING OF PLANT-MATERIAL FROZEN AT HIGH-PRESSURE
    MICHEL, M
    HILLMANN, T
    MULLER, M
    [J]. JOURNAL OF MICROSCOPY, 1991, 163 : 3 - 18
  • [14] Moulders H., 2003, G.I.T. Imag Microsc, V2, P8
  • [15] NICASTRO D, 2005, MICROSC MICROANAL S2, V11, P150
  • [16] CUTTING ARTIFACTS ON ULTRATHIN CRYOSECTIONS OF BIOLOGICAL BULK SPECIMENS
    RICHTER, K
    [J]. MICRON, 1994, 25 (04) : 297 - 308
  • [17] Schwartz C., 2003, MICROSC MICROANAL, V9, P1166
  • [18] Shi SL, 1996, MICROSC RES TECHNIQ, V33, P241
  • [19] The next ice age: cryo-electron tomography of intact cells
    Steven, AC
    Aebi, U
    [J]. TRENDS IN CELL BIOLOGY, 2003, 13 (03) : 107 - 110
  • [20] Walther P, 1999, J MICROSC-OXFORD, V196, P279, DOI 10.1046/j.1365-2818.1999.00595.x