摘要
Purpose: To quantify the effect of contouring variation on stereotactic radiosurgery plan quality metrics for brain metastases. Methods and Materials: Fourteen metastases, each contoured by 8 physicians, formed the basis of this study. A template-based dynamic conformal 5-arc dose distribution was developed for each of the 112 contours, and each dose distribution was applied to the 7 other contours in each patient set. Radiation Therapy Oncology Group (RTOG) plan quality metrics and the Paddick conformity index were calculated for each of the 896 combinations of dose distributions and contours. Results: The ratio of largest to smallest contour volume for each metastasis varied from 1.25 to 4.47, with a median value of 1.68 (n=8). The median absolute difference in RTOG conformity index between the value for the reference contour and the values for the alternative contours was 0.35. The variation of the range of conformity index for all contours for a given tumor varied with the tumor size. Conclusions: The high degree of interobserver contouring variation strongly suggests that peer review or consultation should be adopted to standardize tumor volume prescription. Observer confidence was not reflected in contouring consistency. The impact of contouring variability on plan quality metrics, used as criteria for clinical trial protocol compliance, was such that the category of compliance was robust to interobserver effects only 70% of the time. (C) 2013 Elsevier Inc.
引用
收藏
页码:924 / 931
页数:8
相关论文
共 11 条
  • [1] Quality Indicators in Radiation Oncology
    Albert, Jeffrey M.
    Das, Prajnan
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (04): : 904 - 911
  • [2] Stereotactic radiosurgery for brain AVMs: Role of interobserver variation in target definition on digital subtraction angiography
    Buis, DR
    Lagerwaard, FJ
    Barkhof, F
    Dirven, CMF
    Lycklama, GJ
    Meijer, OWM
    van den Berg, R
    Langendijk, HA
    Slotman, BJ
    Vandertop, WP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01): : 246 - 252
  • [3] Geometrical Analysis of Radiotherapy Target Volume Delineation: a Systematic Review of Reported Comparison Methods
    Hanna, G. G.
    Hounsell, A. R.
    O'Sullivan, J. M.
    [J]. CLINICAL ONCOLOGY, 2010, 22 (07) : 515 - 525
  • [4] A review of methods of analysis in contouring studies for radiation oncology
    Jameson, Michael G.
    Holloway, Lois C.
    Vial, Philip J.
    Vinod, Shalini K.
    Metcalfe, Peter E.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (05) : 401 - 410
  • [5] A simple scoring ratio to index the conformity of radiosurgical treatment plans - Technical note
    Paddick, I
    [J]. JOURNAL OF NEUROSURGERY, 2000, 93 : 219 - 222
  • [6] Irradiation of paranasal sinus tumors, a delineation and dose comparison study
    Rasch, C
    Eisbruch, A
    Remeijer, P
    Bos, L
    Hoogeman, M
    van Herk, M
    Lebesque, JV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01): : 120 - 127
  • [7] RADIATION-THERAPY ONCOLOGY GROUP - RADIOSURGERY QUALITY ASSURANCE GUIDELINES
    SHAW, E
    KLINE, R
    GILLIN, M
    SOUHAMI, L
    HIRSCHFELD, A
    DINAPOLI, R
    MARTIN, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05): : 1231 - 1239
  • [8] Evaluation of stereotactic radiosurgery conformity indices for 170 target volumes in patients with brain metastases
    Stanley, Julia
    Breitman, Karen
    Dunscombe, Peter
    Spencer, David P.
    Lau, Harold
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 245 - 253
  • [9] Interobserver variations in gross tumor volume delineation of brain tumors on computed tomography and impact of magnetic resonance imaging
    Weltens, C
    Menten, J
    Feron, M
    Bellon, E
    Demaerel, P
    Maes, F
    Van den Bogaert, W
    van der Schueren, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) : 49 - 59
  • [10] Factors related to the local treatment failure of gamma knife surgery for metastatic brain tumors
    Woo, Hyun Jin
    Hwang, Sung Kyoo
    Park, Seong Hyun
    Hwang, Jeong Hyun
    Hamm, In Suk
    [J]. ACTA NEUROCHIRURGICA, 2010, 152 (11) : 1909 - 1914