Fault detection in district heating substations

被引:103
作者
Gadd, Henrik [1 ]
Werner, Sven [2 ]
机构
[1] Oresundskraft AB, S-25106 Helsingborg, Sweden
[2] Halmstad Univ, Sch Business Engn & Sci, SE-30118 Halmstad, Sweden
关键词
District heating; Fault detection; Meter reading; RESIDENTIAL BUILDINGS; SYSTEM; PATTERNS;
D O I
10.1016/j.apenergy.2015.07.061
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Current temperature levels in European district heating networks are still too high with respect to future conditions as customer heat demands decrease and new possible heat source options emerge. A considerable reduction of temperature levels can be accomplished by eliminating current faults in substations and customer heating systems. These faults do not receive proper attention today, because neither substations nor customer heating systems are centrally supervised. The focus of this paper has been to identify these faults by annual series of hourly meter readings obtained from automatic meter reading systems at 135 substations in two Swedish district heating systems. Based on threshold methods, various faults were identified in 74% of the substations. The identified faults were divided into three different fault groups: Unsuitable heat load pattern, low average annual temperature difference, and poor substation control. The most important conclusion from this early study of big data volumes is that automatic meter reading systems can provide proactive fault detection by continuous commissioning of district heating substations in the future. A complete reduction of current faults corresponds to approximately half the required reduction of the current temperature levels in the effort toward future low-temperature district heating networks. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 29 条
[1]   Optimisation of a Swedish district heating system with reduced heat demand due to energy efficiency measures in residential buildings [J].
Aberg, M. ;
Henning, D. .
ENERGY POLICY, 2011, 39 (12) :7839-7852
[2]  
Ahonen M., 1996, RES NOTES VTT BUILDI
[3]  
Aronsson S., 1996, Ph.D. Dissertation
[4]   Monitoring the energy consumption in a district heated apartment building in Copenhagen, with specific interest in the thermodynamic performance [J].
Bohm, B ;
Danig, PO .
ENERGY AND BUILDINGS, 2004, 36 (03) :229-236
[5]   Review of automated fault detection and diagnostic tools in air handling units [J].
Bruton, Ken ;
Raftery, Paul ;
Kennedy, Barry ;
Keane, Marcus M. ;
O'Sullivan, D. T. J. .
ENERGY EFFICIENCY, 2014, 7 (02) :335-351
[6]  
Delsing J, 2013, Tech. rep.
[7]  
Delsing J, 2001, NY METOD FUNKTIONSDI
[8]   Heat load patterns in district heating substations [J].
Gadd, Henrik ;
Werner, Sven .
APPLIED ENERGY, 2013, 108 :176-183
[9]  
Gong M., 2012, 13 INT S DISTR HEAT
[10]  
Goransson A, 2009, 200921 SWED DISTR HE