Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view

被引:10
作者
Peters, DC [1 ]
Guttman, MA [1 ]
Dick, AJ [1 ]
Raman, VK [1 ]
Lederman, RJ [1 ]
McVeigh, ER [1 ]
机构
[1] NHLBI, Cardiac Energet Lab, NIH, DHHS, Bethesda, MD 20892 USA
关键词
UNFOLD; reduced field of view (rFOV); projection reconstruction; interventional MRI; radial imaging; catheter tracking; temporal filtering;
D O I
10.1002/mrm.20037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Active catheter imaging was investigated using real-time undersampled projection reconstruction (PR) combined with the temporal filtering technique of reduced field of view (rFOV). Real-time rFOV processing was interactively enabled during highly undersampled catheter imaging, resulting in improved artifact suppression with better temporal resolution than that obtained by view-sharing, Imaging with 64 to 32 projections provided a resolution of 2 x 2 x 8 mm, and four to eight true frames per second. Image artifacts were reduced when rFOV processing was applied to the undersampled images. A comparison with Cartesian rFOV showed that PR image quality is less susceptible to aliasing that results from rFOV imaging with a wholly dynamic outer FOV. Simulations and MRI experiments demonstrated that PR rFOV provides significant artifact suppression, even for a fully dynamic FOV. The near doubling of temporal resolution that is possible with PR rFOV permits accurate monitoring of highly dynamic events, such as catheter movements, and arrhythmias, such as ventricular ectopy. Published 2004 Wiley-Liss, Inc.(dagger)
引用
收藏
页码:761 / 767
页数:7
相关论文
共 28 条
[1]   Multiple field of view MR fluoroscopy [J].
Aksit, P ;
Derbyshire, JA ;
Serfaty, JM ;
Atalar, E .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) :53-60
[2]   Real-time MR guidance for inferior vena cava filter placement in an animal model [J].
Bücker, A ;
Neuerburg, JM ;
Adam, GB ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Günther, RW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (06) :753-756
[3]   A rapid look-up table method for reconstructing MR images from arbitrary K-space trajectories [J].
Dale, B ;
Wendt, M ;
Duerk, JL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (03) :207-217
[4]   Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studies [J].
Di Bella, EVR ;
Wu, YJ ;
Alexander, AL ;
Parker, DL ;
Green, D ;
McGann, CJ .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) :895-902
[5]   Temporal resolution improvement in dynamic imaging [J].
Fredrickson, JO ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (04) :621-625
[6]   Real-time volume rendered MRI for interventional guidance (vol 4, pg 431, 2002) [J].
Guttman, MA ;
Lederman, RJ ;
Sorger, JM ;
McVeigh, ER .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (02) :407-407
[7]  
GUTTMAN MA, 2002, P 10 ANN M ISMRM, P2250
[8]  
Kellman P, 2000, MAGNET RESON MED, V44, P933, DOI 10.1002/1522-2594(200012)44:6<933::AID-MRM15>3.0.CO
[9]  
2-I
[10]  
Larson A, 2002, P 10 ANN M ISMRM, P77