Repeatability of MRI for radiotherapy planning for pelvic, brain, and head and neck malignancies

被引:0
|
作者
Heinke, Monique Y. Y. [1 ]
Holloway, Lois [1 ,2 ,3 ,4 ,5 ]
Rai, Robba [1 ]
Vinod, Shalini K. K. [1 ,2 ,3 ]
机构
[1] Liverpool & Macarthur Canc Therapy Ctr, Liverpool, NSW, Australia
[2] Ingham Inst Appl Med Res, Liverpool, NSW, Australia
[3] Univ New South Wales, South Western Sydney Clin Sch, Liverpool, NSW, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[5] Univ Sydney, Inst Med Phys, Sch Phys, Camperdown, NSW, Australia
关键词
MR-guided radiotherapy; radiotherapy planning; repeatability; MRI-linac; MRL; image registration; GUIDED ADAPTIVE BRACHYTHERAPY; BEAM RADIATION-THERAPY; CERVICAL-CANCER; INTEROBSERVER VARIABILITY; VOLUME DELINEATION; CT; PROSTATE; DISTORTION; IMPACT; TARGET;
D O I
10.3389/fphy.2022.879707
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Objectives: The objective of this study was to assess the repeatability of MRI for the purpose of radiotherapy treatment planning by considering the difference in registering MRI to MRI compared to registering CT and MRI.Methods: Fifty patients undergoing radiotherapy planning for gynaecological, prostate, rectal, head and neck and CNS malignancies had a planning CT followed by two T2-weighted MRIs. Anatomical landmarks were contoured on each dataset and the images were rigidly registered. Centre of Mass (COM), Dice Similarity Coefficient (DSC), and Mean Distance to Agreement (MDA) were calculated to assess structure volume and position comparing CT-MRI and MRI-MRI.Results: DSC and MDA demonstrated more consistency in delineated volumes for MRI-MRI than for the CT-MRI comparison. The median DSC values were >= 0.8 for 15 of 46 contoured structures for the CT-MRI comparison and 21 of 23 structures for the MRI-MRI comparison. MDA values were <= 1 mm for 11 of 46 structures for the CT-MRI comparison and 18 of 23 structures for the MRI-MRI comparisons. COM were also more consistent between MRI-MRI than between CT-MRI.Conclusion: There was less variability of anatomical structures between repeated MRIs than registered CT and MRI datasets, demonstrating consistency of MRI for volume delineation in radiotherapy planning.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Added value of diffusion-weighted MRI for nodal radiotherapy planning in pelvic malignancies
    Sushentsev, N.
    Martin, H.
    Rimmer, Y.
    Barrett, T.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2019, 21 (10) : 1383 - 1389
  • [2] Added value of diffusion-weighted MRI for nodal radiotherapy planning in pelvic malignancies
    N. Sushentsev
    H. Martin
    Y. Rimmer
    T. Barrett
    Clinical and Translational Oncology, 2019, 21 : 1383 - 1389
  • [3] Repeatability of functional MRI for conformal avoidance radiotherapy planning
    Garcia-Alvarez, R
    Liney, GP
    Beavis, AW
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (02) : 108 - 114
  • [4] PET/CT in radiotherapy planning in head and neck cancers
    Vicente, A. M. Garcia
    Castrejon, A. Soriano
    Londono, G. Andres Jimenez
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2015, 39 (05): : 465 - 470
  • [5] Molecular Imaging in Radiotherapy Planning for Head and Neck Tumors
    Gregoire, Vincent
    Chiti, Arturo
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (03) : 331 - 334
  • [6] The use of deformable image registration to integrate diagnostic MRI into the radiotherapy planning pathway for head and neck cancer
    Chuter, Robert
    Prestwich, Robin
    Bird, David
    Scarsbrook, Andrew
    Sykes, Jonathan
    Wilson, Daniel
    Speight, Richard
    RADIOTHERAPY AND ONCOLOGY, 2017, 122 (02) : 229 - 235
  • [7] Commissioning of a new wide-bore MRI scanner for radiotherapy planning of head and neck cancer
    Liney, G. P.
    Owen, S. C.
    Beaumont, A. K. E.
    Lazar, V. R.
    Manton, D. J.
    Beavis, A. W.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1027)
  • [8] A new role of PET/CT for target delineation for radiotherapy treatment planning for head and neck carcinomas
    Zygogianni, Anna
    Kyrgias, George
    Kouvaris, John
    Pistevou-Gompaki, Kyriaki
    Kouloulias, Vassilis
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2012, 15 (02): : 139 - 143
  • [9] DENTALMAPS: AUTOMATIC DENTAL DELINEATION FOR RADIOTHERAPY PLANNING IN HEAD-AND-NECK CANCER
    Thariat, Juliette
    Ramus, Liliane
    Maingon, Philippe
    Odin, Guillaume
    Gregoire, Vincent
    Darcourt, Vincent
    Guevara, Nicolas
    Orlanducci, Marie-Helene
    Marcie, Serge
    Poissonnet, Gilles
    Marcy, Pierre-Yves
    Bozec, Alex
    Dassonville, Olivier
    Castillo, Laurent
    Demard, Francois
    Santini, Jose
    Malandain, Gregoire
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1858 - 1865
  • [10] Innovations in Radiotherapy Planning of Head and Neck Cancers: Role of PET
    Troost, Esther G. C.
    Schinagl, Dominic A. X.
    Bussink, Johan
    Boerman, Otto C.
    van der Kogel, Albert J.
    Oyen, Wim J. G.
    Kaanders, Johannes H. A. M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (01) : 66 - 76