Substrates and Controls for the Quantitative Detection of Active Botulinum Neurotoxin in Protease-Containing Samples

被引:14
作者
Bagramyan, Karine [1 ]
Kaplan, Bruce E. [1 ]
Cheng, Luisa W. [2 ]
Strotmeier, Jasmin [3 ]
Rummel, Andreas [3 ]
Kalkum, Markus [1 ]
机构
[1] City Hope Natl Med Ctr, Beckman Res Inst, Dept Immunol, Duarte, CA 91010 USA
[2] USDA ARS, Foodborne Contaminants Res Unit, Western Reg Res Ctr, Albany, CA 94710 USA
[3] Hannover Med Sch, Inst Toxikol, D-30623 Hannover, Germany
基金
美国农业部; 美国国家卫生研究院;
关键词
TOXIN TYPE-A; CLOSTRIDIUM-BOTULINUM; SEROTYPE-A; MECHANISM; TETANUS; PHARMACOKINETICS; RECOGNITION; PROTEOLYSIS; EXTRACTION; INJECTIONS;
D O I
10.1021/ac4008418
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Botulinum neurotoldns (BoNTs) are used in a wide variety of medical applications, but there is limited pharmacokinetic data on active BoNT. Monitoring BoNT activity in the circulation is challenging because BoNTs are highly toxic and are rapidly taken up by neurons and removed from the bloodstream. Previously we reported, a sensitive BoNT "Assay with a Large Immunosorbent Surface Area" that uses conversion of fluorogenic peptide substrates to measure the intrinsic endopeptidase activity of bead-captured BoNT However, in complex biological samples, protease contaminants can also cleave the substrates, reducing sensitivity and specificity of the assay. Here, we present a novel, set of, fluorogenic peptides that serve as BoNT-specific substrates and protease-sensitive controls. BoNT-cleavable substrates contain a C-terminal Nle, while BoNT-noncleavable controls contain its isomer epsilon-Ahx. The substrates are cleaved by BoNT subtypes Al-A3 an A5. Substrates and control peptides can be cleaved by non-BoNT proteases (e.g., trypsin, proteinase K, and thermolysin) while obeying Michaelis-Menten kinetics. Using this novel substrate/control set, we studied BoNT/A1 activity in two mouse models of botulism. We detected BoNT/A serum activities ranging from similar to 3600 to 10 amol/L., in blood of mice that had been intravenously injected 1 h prior with BoNT/A1 complex (100 to 4 pg/mouse). We also detected the endopeptidase activity of orally administered BoNT/A1 complex (1 mu g) in blood 5 h after administration; activity was greatest 7 h after administration. Redistribution and elevation rates for active toxin were measured and are comparable to those reported for inactive toxin.
引用
收藏
页码:5569 / 5576
页数:8
相关论文
共 56 条
[1]   Protection by the heavy metal chelator N,N,N',N'-tetrakis (2-pyridylmethyl)ethylenediamine (TPEN) against the lethal action of botulinum neurotoxin A and B [J].
Adler, M ;
Dinterman, RE ;
Wannemacher, RW .
TOXICON, 1997, 35 (07) :1089-1100
[2]   The role of systemic handling in the pathophysiologic actions of botulinum toxin [J].
Al-Saleem, Fetweh H. ;
Ancharski, Denise M. ;
Ravichandran, Easwaran ;
Joshi, Suresh G. ;
Singh, Ajay K. ;
Gong, Yujing ;
Simpson, Lance L. .
JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS, 2008, 326 (03) :856-863
[3]  
[Anonymous], 1989, Molecular Cloning: A Laboratory
[4]   Botulinum toxin as a biological weapon - Medical and public health management [J].
Arnon, SS ;
Schechter, R ;
Inglesby, TV ;
Henderson, DA ;
Bartlett, JG ;
Ascher, MS ;
Eitzen, E ;
Fine, AD ;
Hauer, J ;
Layton, M ;
Lillibridge, S ;
Osterholm, MT ;
O'Toole, T ;
Parker, G ;
Perl, TM ;
Russell, PK ;
Swerdlow, DL ;
Tonat, K .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (08) :1059-1070
[5]  
Bagramyan K, 2011, METHODS MOL BIOL, V739, P23, DOI 10.1007/978-1-61779-102-4_3
[6]   Attomolar Detection of Botulinum Toxin Type A in Complex Biological Matrices [J].
Bagramyan, Karine ;
Barash, Jason R. ;
Arnon, Stephen S. ;
Kalkum, Markus .
PLOS ONE, 2008, 3 (04)
[7]  
BINZ T, 1994, J BIOL CHEM, V269, P1617
[8]  
BONVENTRE PF, 1979, REV INFECT DIS, V1, P663
[9]   From the mouse to the mass spectrometer: Detection and differentiation of the endoproteinase activities of botulinum neurotoxins A-G by mass spectrometry [J].
Boyer, AE ;
Moura, H ;
Woolfitt, AR ;
Kalb, SR ;
McWilliams, LG ;
Pavlopoulos, A ;
Schmidt, JG ;
Ashley, DL ;
Barr, JR .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :3916-3924
[10]   pH sensing in living cells using fluorescent microspheres [J].
Bradley, Mark ;
Alexander, Lois ;
Duncan, Karen ;
Chennaoui, Mourad ;
Jones, Anita C. ;
Sanchez-Martin, Rosario M. .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2008, 18 (01) :313-317