3D Cine Displacement-Encoded MRI of Pulsatile Brain Motion

被引:67
作者
Soellinger, Michaela
Rutz, Andrea K.
Kozerke, Sebastian
Boesiger, Peter [1 ,2 ]
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, CH-8092 Zurich, Switzerland
关键词
3D; DENSE; brain motion; CSF; displacement imaging; PHASE-CONTRAST MR; CEREBROSPINAL-FLUID DYNAMICS; MAGNETIC-RESONANCE; FLOW; HYDROCEPHALUS; ECHOES; DENSE; QUANTIFICATION; VOLUNTEERS; PRESSURE;
D O I
10.1002/mrm.21802
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Pulsatile brain motion is considered to be an important mechanical link between blood and cerebrospinal fluid (CSF) dynamics. Like many severe brain diseases, different types of hydrocephalus are associated with impairment of these dynamics. In this work a cine displacement-encoded imaging method employing stimulated echoes (DENSE) and a three-dimensional (3D) segmented echo-planar Imaging (EPI) readout for brain motion measurements in all three spatial directions is presented. Displacement-encoded data sets of 12 healthy volunteers were analyzed with respect to reproducibility, periodicity, and intra- as well as intersubject physiological consistency. In addition, displacement values were compared with data derived from phase-contrast (PC) velocity measurements in a subset of all measured subjects. Using DENSE, displacements as low as 0.01 mm could be detected and observation of the 3D pulse pressure wave propagation was possible. Among other parameters, peak displacements in the central brain regions were measured: feet-head (FH): thalamus (0.13 +/- 0.01 mm); right-left (RL): thalamus (0.06 +/- 0.01 mm); and anterior-posterior (AP): caudate nucleus (0.05 +/- 0.01 mm). Magn Reson Med 61:153-162, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:153 / 162
页数:10
相关论文
共 34 条
  • [1] ABDULRAHMAN H, 2005, FAST 3 DIMENSIONAL P, P32
  • [2] Meta-DENSE complex acquisition for reduced intravoxel dephasing
    Aletras, AH
    Aral, AE
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2004, 169 (02) : 246 - 249
  • [3] DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI
    Aletras, AH
    Ding, SJ
    Balaban, RS
    Wen, H
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) : 247 - 252
  • [4] Hemodynamically independent analysis of cerebrospinal fluid and brain motion observed with dynamic phase contrast MRI
    Alperin, N
    Vikingstad, EM
    GomezAnson, B
    Levin, DN
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 741 - 754
  • [5] Relationship between cerebrospinal fluid and blood dynamics in healthy volunteers and patients with communicating hydrocephalus
    Balédent, O
    Gondry-Jouet, C
    Meyer, ME
    De Marco, G
    Le Gars, D
    Henry-Feugeas, MC
    Idy-Peretti, I
    [J]. INVESTIGATIVE RADIOLOGY, 2004, 39 (01) : 45 - 55
  • [6] Cerebrospinal fluid dynamics and relation with blood flow -: A magnetic resonance study with semiautomated cerebrospinal fluid segmentation
    Balédent, O
    Henry-Feugeas, MCC
    Idy-Peretti, I
    [J]. INVESTIGATIVE RADIOLOGY, 2001, 36 (07) : 368 - 377
  • [7] Concomitant gradient terms in phase contrast MR: Analysis and correction
    Bernstein, MA
    Zhou, XHJ
    Polzin, JA
    King, KF
    Ganin, A
    Pelc, NJ
    Glover, GH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) : 300 - 308
  • [8] FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING
    BUONOCORE, MH
    BOGREN, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) : 141 - 154
  • [9] BRAIN MOTION - MEASUREMENT WITH PHASE-CONTRAST MR IMAGING
    ENZMANN, DR
    PELC, NJ
    [J]. RADIOLOGY, 1992, 185 (03) : 653 - 660
  • [10] Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes
    Epstein, FH
    Gilson, WD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) : 774 - 781