Early and Late Leaflet Thrombosis After Transcatheter Aortic Valve Replacement A Multicenter Initiative From the OCEAN-TAVI Registry

被引:95
作者
Yanagisawa, Ryo [1 ]
Tanaka, Makoto [1 ]
Yashima, Fumiaki [1 ]
Arai, Takahide [1 ]
Jinzaki, Masahiro [2 ]
Shimizu, Hideyuki [3 ]
Fukuda, Keiichi [1 ]
Watanabe, Yusuke [4 ]
Naganuma, Toru [5 ]
Higashimori, Akihiro [6 ]
Mizutani, Kazuki [7 ]
Araki, Motoharu [8 ]
Tada, Norio [9 ]
Yamanaka, Futoshi [10 ]
Otsuka, Toshiaki [11 ,12 ]
Yamamoto, Masanori [13 ,14 ]
Hayashida, Kentaro [1 ]
机构
[1] Keio Univ, Sch Med, Dept Cardiol, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Cardiovasc Surg, Tokyo, Japan
[4] Teikyo Univ, Sch Med, Tokyo, Japan
[5] New Tokyo Hosp, Matsudo, Chiba, Japan
[6] Kishiwada Tokushukai Hosp, Osaka, Japan
[7] Osaka City Gen Hosp, Osaka, Japan
[8] Saiseikai Yokohama City Eastern Hosp, Tsurumi, Japan
[9] Sendai Kousei Hosp, Sendai, Miyagi, Japan
[10] Shonan Kamakura Gen Hosp, Kamakura, Kanagawa, Japan
[11] Nippon Med Sch, Dept Hyg & Publ Hlth, Tokyo, Japan
[12] Nippon Med Sch, Ctr Clin Res, Tokyo, Japan
[13] Toyohashi Heart Ctr, Toyohashi, Aichi, Japan
[14] Nagoya Heart Ctr, Nagoya, Aichi, Japan
关键词
aortic valve stenosis; heart failure; multidetector computed tomography; thrombosis; transcatheter aortic valve replacement; IMPLANTATION; RISK; COMPLICATIONS; PREDICTORS; FAILURE;
D O I
10.1161/CIRCINTERVENTIONS.118.007349
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The occurrence and clinical impact of untreated subclinical leaflet thrombosis beyond 1 year after transcatheter aortic valve replacement still remain unclear. METHODS AND RESULTS: In a multicenter transcatheter aortic valve replacement registry, we analyzed data from 485 patients who underwent 4-dimensional multidetector computed tomography posttranscatheter aortic valve replacement performed to survey hypoattenuated leaflet thickening with reduced leaflet motion compatible with thrombus at a median of 3 days, 6 months, 1 year, 2 years, and 3 years. Incidence, predictors, and clinical outcomes of early (median 3 days) and late (>30 days) leaflet thrombosis were assessed. Additional anticoagulation was not administered because of subclinical findings at the time of computed tomography in all patients. Early leaflet thrombosis occurred in 45 (9.3%) of 485 patients. Mean pressure gradient at discharge was higher in patients with early leaflet thrombosis than in those without. Independent predictors of early leaflet thrombosis in balloon-expandable prostheses were low-flow, low-gradient aortic stenosis, severe prosthesis-patient mismatch, and 29-mm prostheses. No predictors could be identified for self-expanding prosthesis. Cumulative event rates of death, stroke, or rehospitalization for heart failure over 2 years were 10.7% and 16.9% in patients with and without early leaflet thrombosis, respectively (P=0.63). Late leaflet thrombosis occurred late up to 3 years, and male sex and paravalvular leak less than mild were independent predictors. CONCLUSIONS: Untreated early leaflet thrombosis did not affect the cumulative event rates of death, stroke, and rehospitalization for heart failure. Late leaflet thrombosis was newly detected during 3-year follow-up.
引用
收藏
页数:9
相关论文
共 22 条
[1]   Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study [J].
Chakravarty, Tarun ;
Sondergaard, Lars ;
Friedman, John ;
De Backer, Ole ;
Berman, Daniel ;
Kofoed, Klaus F. ;
Jilaihawi, Hasan ;
Shiota, Takahiro ;
Abramowitz, Yigal ;
Jorgensen, Troels H. ;
Rami, Tanya ;
Israr, Sharjeel ;
Fontana, Gregory ;
de Knegt, Martina ;
Fuchs, Andreas ;
Lyden, Patrick ;
Trento, Alfredo ;
Bhatt, Deepak L. ;
Leon, Martin B. ;
Makkar, Raj R. .
LANCET, 2017, 389 (10087) :2383-2392
[2]   Thrombus Formation Following Transcatheter Aortic Valve Replacement [J].
De Marchena, Eduardo ;
Mesa, Julian ;
Pomenti, Sydney ;
Kall, Christian Marin y ;
Marincic, Ximena ;
Yahagi, Kazuyuki ;
Ladich, Elena ;
Kutz, Robert ;
Aga, Yaar ;
Ragosta, Michael ;
Chawla, Atul ;
Ring, Michael E. ;
Virmani, Renu .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (05) :728-739
[3]   Incidence, Timing, and Predictors of Valve Hemodynamic Deterioration After Transcatheter Aortic Valve Replacement Multicenter Registry [J].
Del Trigo, Maria ;
Munoz-Garcia, Antonio J. ;
Wijeysundera, Harindra C. ;
Nombela-Franco, Luis ;
Cheema, Asim N. ;
Gutierrez, Enrique ;
Serra, Vicenc ;
Kefer, Joelle ;
Amat-Santos, Ignacio J. ;
Benitez, Luis M. ;
Mewa, Jumana ;
Jimenez-Quevedo, Pilar ;
Alnasser, Sami ;
Garcia del Blanco, Bruno ;
Dager, Antonio ;
Abdul-Jawad Altisent, Omar ;
Puri, Rishi ;
Campelo-Parada, Francisco ;
Dahou, Abdellaziz ;
Paradis, Jean-Michel ;
Dumont, Eric ;
Pibarot, Philippe ;
Rodes-Cabau, Josep .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (06) :644-655
[4]   Bioprosthetic Valve Thrombosis Versus Structural Failure Clinical and Echocardiographic Predictors [J].
Egbe, Alexander C. ;
Pislaru, Sorin V. ;
Pellikka, Patricia A. ;
Poterucha, Joseph T. ;
Schaff, Hartzell V. ;
Maleszewski, Joseph J. ;
Connolly, Heidi M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) :2285-2294
[5]   Transcatheter Aortic Valve Thrombosis Incidence, Predisposing Factors, and Clinical Implications [J].
Hansson, Nicolaj C. ;
Grove, Erik L. ;
Andersen, Henning R. ;
Leipsic, Jonathon ;
Mathiassen, Ole N. ;
Jensen, Jesper M. ;
Jensen, Kaare T. ;
Blanke, Philipp ;
Leetmaa, Tina ;
Tang, Mariann ;
Krusell, Lars R. ;
Klaaborg, Kaj E. ;
Christiansen, Evald H. ;
Terp, Kim ;
Terkelsen, Christian J. ;
Poulsen, Steen H. ;
Webb, John ;
Botker, Hans Erik ;
Norgaard, Bjarne L. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (19) :2059-2069
[6]   Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement Incidence, Characteristics, and Treatment Outcomes [J].
Jose, John ;
Sulimov, Dmitriy S. ;
El-Mawardy, Mohamed ;
Sato, Takao ;
Allali, Abdelhakim ;
Holy, Erik W. ;
Becker, Bjorn ;
Landt, Martin ;
Kebernik, Julia ;
Schwarz, Bettina ;
Richardt, Gert ;
Abdel-Wahab, Mohamed .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (07) :686-697
[7]   Impact of Subclinical Vascular Complications Detected by Systematic Postprocedural Multidetector Computed Tomography After Transcatheter Aortic Valve Implantation Using Balloon-Expandable Edwards SAPIEN XT Heart Valve [J].
Kakefuda, Yuki ;
Hayashida, Kentaro ;
Yamada, Yoshitake ;
Yashima, Fumiaki ;
Inohara, Taku ;
Yanagisawa, Ryo ;
Tanaka, Makoto ;
Arai, Takahide ;
Kawakami, Takashi ;
Maekawa, Yuichiro ;
Tsuruta, Hikaru ;
Itabashi, Yuji ;
Murata, Mitsushige ;
Sano, Motoaki ;
Okamoto, Kazuma ;
Yoshitake, Akihiro ;
Shimizu, Hideyuki ;
Jinzaki, Masahiro ;
Fukuda, Keiichi .
AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (07) :1100-1105
[8]  
Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1093/ejcts/ezs533, 10.1016/j.jacc.2012.09.001]
[9]   Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis [J].
Latib, Azeem ;
Naganuma, Toru ;
Abdel-Wahab, Mohamed ;
Danenberg, Haim ;
Cota, Linda ;
Barbanti, Marco ;
Baumgartner, Helmut ;
Finkelstein, Ariel ;
Legrand, Victor ;
Suarez de Lezo, Jose ;
Kefer, Joelle ;
Messika-Zeitoun, David ;
Richardt, Gert ;
Stabile, Eugenio ;
Kaleschke, Gerrit ;
Vahanian, Alec ;
Laborde, Jean-Claude ;
Leon, Martin B. ;
Webb, John G. ;
Panoulas, Vasileios F. ;
Maisano, Francesco ;
Alfieri, Ottavio ;
Colombo, Antonio .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (04)
[10]   Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography [J].
Leetmaa, Tina ;
Hansson, Nicolaj C. ;
Leipsic, Jonathon ;
Jensen, Kaare ;
Poulsen, Steen H. ;
Andersen, Henning R. ;
Jensen, Jesper M. ;
Webb, John ;
Blanke, Philipp ;
Tang, Mariann ;
Norgaard, Bjarne L. .
Circulation-Cardiovascular Interventions, 2015, 8 (04)