Simultaneous Determination of Inorganic Anions and Cations in Water and Biological Samples by Capillary Electrophoresis with a Capacitive Coupled Contactless Conductivity Detector Using Capillary Filling Method

被引:16
|
作者
Yamamoto, Sachio [1 ]
Fujiwara, Haruka [1 ]
Maruyama, Katsushi [1 ]
Tanaka, Yoshihide [1 ]
Kinoshita, Mitsuhiro [1 ,2 ]
Suzuki, Shigeo [1 ,2 ]
机构
[1] Kindai Univ, Fac Pharmaceut Sci, 3-4-1 Kowakae, Higashiosaka, Osaka 5778502, Japan
[2] Kindai Univ, Antiaging Ctr, 3-4-1 Kowakae, Higashiosaka, Osaka 5778502, Japan
基金
日本学术振兴会;
关键词
Capillary electrophoresis (CE); capacitively coupled contactless conductivity detector ((CD)-D-4); capillary filling method (CMF); water analysis; INJECTION-ANALYSIS MANIFOLD; EXHALED BREATH CONDENSATE; SIMULTANEOUS SEPARATION; STEP WIDTH; RESOLUTION;
D O I
10.2116/analsci.18P422
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method for concurrent analysis of inorganic anions and cations has been developed using a capillary electrophoresis (CE)-capacitively coupled contactless conductivity detector ((CD)-D-4) system. Although hydrodynamic and electrokinetie injection techniques have been widely used in CE, we employed a capillary filling method (CFM) for the analysis of inorganic ions. The procedure is relatively simple and has the advantage that CMF does not require pressure control and vial exchange. Three anions (chloride, sulfate, nitrate) and five cations (ammonium, potassium, sodium, magnesium, calcium) were successfully separated and detected at ppm levels within 80 s using a 9 mM histidine/15 mM malic acid (pH 3.6) containing 50 mM N-dodecyl-N,N-dimethyl-3-ammonio-1-propanesulfonate as background electrolyte. Applying this analytical condition, the electroosmotic flow is negligible and anions and cations were migrated concurrently to different polarities according to their electrophoretic mobility. Obtained raw data showed stepwise increases in detected conductivity due to the migration of sample components, which expresses as peak profiles by differentiation of electropherograms. The RSD values of the peak area and migration times for the anions and cations were satisfactory and were less than 5.15 and 2.04%, respectively. The developed method was applied for the analysis of inorganic anions and cations in commercial mineral waters, tap water, urine, and exhaled breath condensate. These results indicate that the CE-(CD)-D-4 system with CFM is suitable for the rapid analysis of inorganic anions and cations in various samples.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 50 条
  • [31] SIMULTANEOUS DETERMINATION OF CATIONS BY CAPILLARY ELECTROPHORESIS WITH CONTACTLESS CONDUCTIVITY DETECTION PERFORMED IN A HOME-MADE EQUIPMENT
    de Carvalho, Leandro M.
    Spengler, Cristiane
    de Lima, Ana Paula S.
    Raabe, Alice
    Martini, Mariele
    do Nascimento, Paulo C.
    Bohrer, Denise
    QUIMICA NOVA, 2009, 32 (08): : 2203 - 2208
  • [32] Capillary ion electrophoresis–capacitively coupled contactless conductivity detection of inorganic cations in human saliva on a polyvinyl alcohol-coated capillary
    Masanobu Mori
    Maki Kaseda
    Tsukasa Yamamoto
    Sachiko Yamada
    Hideyuki Itabashi
    Analytical and Bioanalytical Chemistry, 2012, 402 : 2425 - 2430
  • [33] Dual-channel capillary electrophoresis for simultaneous determination of cations and anions
    Opekar, Frantisek
    Tuma, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1446 : 158 - 163
  • [34] Study on the potential application of salivary inorganic anions in clinical diagnosis by capillary electrophoresis coupled with contactless conductivity detection
    Guo, Lin
    Wang, Yu
    Zheng, Yiliang
    Huang, Zhipeng
    Cheng, Yiyuan
    Ye, Jiannong
    Chu, Qingcui
    Huang, Dongping
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1014 : 70 - 74
  • [36] Determination of γ-hydroxybutyric acid in clinical samples using capillary electrophoresis with contactless conductivity detection
    Gong, Xiao Yang
    Kuban, Pavel
    Scholer, Andre
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (01) : 100 - 104
  • [37] Optimization of background electrolyte composition for simultaneous contactless conductivity and fluorescence detection in capillary electrophoresis of biological samples
    Lacna, Julia
    Prikryl, Jan
    Teshima, Norio
    Murakami, Hiroya
    Esaka, Yukihiro
    Foret, Frantisek
    Kuban, Petr
    ELECTROPHORESIS, 2019, 40 (18-19) : 2390 - 2397
  • [38] Integration of a contactless conductivity detector into a commercial capillary cassette -: Detection of inorganic cations and catecholamines
    Vuorinen, PS
    Jussila, M
    Sirén, H
    Palonen, S
    Riekkola, ML
    JOURNAL OF CHROMATOGRAPHY A, 2003, 990 (1-2) : 45 - 52
  • [39] Determination of amino acids by capillary electrophoresis with differential resonant contactless conductivity detector
    Shen, Dazhong
    Li, Yaolong
    Zhang, Zhenli
    Zhang, Ping
    Kang, Qi
    TALANTA, 2013, 104 : 39 - 43
  • [40] Simultaneous determination of inorganic cations and anion in medical electrolytes by capillary electrophoresis
    Abe, S
    Murayama, JI
    Maeda, M
    Arakawa, H
    ANALYTICAL LETTERS, 2006, 39 (02) : 317 - 326