Simultaneous Determination of Inorganic Anions and Cations in Water and Biological Samples by Capillary Electrophoresis with a Capacitive Coupled Contactless Conductivity Detector Using Capillary Filling Method

被引:16
作者
Yamamoto, Sachio [1 ]
Fujiwara, Haruka [1 ]
Maruyama, Katsushi [1 ]
Tanaka, Yoshihide [1 ]
Kinoshita, Mitsuhiro [1 ,2 ]
Suzuki, Shigeo [1 ,2 ]
机构
[1] Kindai Univ, Fac Pharmaceut Sci, 3-4-1 Kowakae, Higashiosaka, Osaka 5778502, Japan
[2] Kindai Univ, Antiaging Ctr, 3-4-1 Kowakae, Higashiosaka, Osaka 5778502, Japan
基金
日本学术振兴会;
关键词
Capillary electrophoresis (CE); capacitively coupled contactless conductivity detector ((CD)-D-4); capillary filling method (CMF); water analysis; INJECTION-ANALYSIS MANIFOLD; EXHALED BREATH CONDENSATE; SIMULTANEOUS SEPARATION; STEP WIDTH; RESOLUTION;
D O I
10.2116/analsci.18P422
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method for concurrent analysis of inorganic anions and cations has been developed using a capillary electrophoresis (CE)-capacitively coupled contactless conductivity detector ((CD)-D-4) system. Although hydrodynamic and electrokinetie injection techniques have been widely used in CE, we employed a capillary filling method (CFM) for the analysis of inorganic ions. The procedure is relatively simple and has the advantage that CMF does not require pressure control and vial exchange. Three anions (chloride, sulfate, nitrate) and five cations (ammonium, potassium, sodium, magnesium, calcium) were successfully separated and detected at ppm levels within 80 s using a 9 mM histidine/15 mM malic acid (pH 3.6) containing 50 mM N-dodecyl-N,N-dimethyl-3-ammonio-1-propanesulfonate as background electrolyte. Applying this analytical condition, the electroosmotic flow is negligible and anions and cations were migrated concurrently to different polarities according to their electrophoretic mobility. Obtained raw data showed stepwise increases in detected conductivity due to the migration of sample components, which expresses as peak profiles by differentiation of electropherograms. The RSD values of the peak area and migration times for the anions and cations were satisfactory and were less than 5.15 and 2.04%, respectively. The developed method was applied for the analysis of inorganic anions and cations in commercial mineral waters, tap water, urine, and exhaled breath condensate. These results indicate that the CE-(CD)-D-4 system with CFM is suitable for the rapid analysis of inorganic anions and cations in various samples.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 34 条
[31]   A new apparatus for electrophoretic analysis of colloidal mixtures. [J].
Tiselius, A .
TRANSACTIONS OF THE FARADAY SOCIETY, 1937, 33 (01) :0524-0530
[32]   An electrophoretic study of immune sera and purified antibody preparations [J].
Tiselius, A ;
Kabat, EA .
JOURNAL OF EXPERIMENTAL MEDICINE, 1939, 69 (01) :119-131
[33]   A new method to determine biological sample volume by short end multiple injection capillary electrophoresis: Application in determination of nitrate and thiocyanate in human saliva [J].
Vitali, Luciano ;
Favere, Valfredo T. ;
Micke, Gustavo A. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (16) :2327-2333
[34]   Contactless conductivity detection for capillary electrophoresis [J].
Zemann, AJ ;
Schnell, E ;
Volgger, D ;
Bonn, GK .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :563-567