Feasibility of neonatal lung imaging using electrical impedance tomography

被引:11
|
作者
Taktak, A [1 ]
Spencer, A [1 ]
Record, P [1 ]
Gadd, R [1 ]
Rolfe, P [1 ]
机构
[1] KEELE UNIV,N STAFFORDSHIRE HOSP,DEPT PAEDIAT,STOKE ON TRENT ST4 7QB,STAFFS,ENGLAND
关键词
neonatal lung imaging; electrical impedance tomography;
D O I
10.1016/0378-3782(95)01700-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The feasibility of detecting the lungs in preterm babies using electrical impedance tomography (EIT) was investigated, A single frequency instrument using 16 electrodes to apply current and detect peripheral voltages was constructed. The instrument applied AC current of 1.5 mA peak-peak at a carrier frequency of 20 kHz, Images were reconstructed using a sensitivity regions backprojection method. A 9-day-old preterm baby was tested and data were collected at a speed of 10 frames/s, A dynamic image showing the lungs at full inspiration referenced to expiration is illustrated in this paper. Impedance measurements taken across the chest during the first 2 s did not show a clear pattern thus demonstrating irregular breathing. Region of interest analysis were carried out on the reconstructed images and tracked with time. Fourier transforms were then performed on these signals and a fundamental frequency at 1 Hz, corresponding to normal breathing rate of 60 breaths/min, was detected. Harmonics of the signal caused distortion especially on the left lung where the effects of cardiac events were more dominant.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [1] Practical factors in neonatal lung imaging using electrical impedance tomography
    Taktak, A.
    Record, P.
    Gadd, R.
    Rolfe, P.
    Medical and Biological Engineering and Computing, 1995, 33 (02): : 202 - 205
  • [2] PRACTICAL FACTORS IN NEONATAL LUNG IMAGING USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    TAKTAK, A
    RECORD, P
    GADD, R
    ROLFE, P
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (02) : 202 - 205
  • [3] Capacitively Coupled Electrical Impedance Tomography in Lung Imaging
    Guo, Yuxi
    Zhu, Liying
    Wang, Minmin
    Jiang, Yandan
    Soleimani, Manuchehr
    Zhang, Maomao
    IEEE SENSORS JOURNAL, 2024, 24 (20) : 33072 - 33082
  • [4] Functional imaging of neonatal evoked responses with electrical impedance tomography
    Tidswell, T
    Bayford, R
    Wyatt, J
    Holder, D
    NEUROIMAGE, 2001, 13 (06) : S1268 - S1268
  • [5] Feasibility of imaging evoked activity throughout the rat brain using electrical impedance tomography
    Faulkner, Mayo
    Hannan, Sana
    Aristovich, Kirill
    Avery, James
    Holder, David
    NEUROIMAGE, 2018, 178 : 1 - 10
  • [6] In vivo Detection and Imaging of Intraventricular Hemorrhage in Neonatal Piglets Using Electrical Impedance Tomography
    LI Yan-dong
    SHI Xue-tao
    DAI Meng
    YOU Fu-sheng
    XU Can-hua
    FU Feng
    LIU Rui-gang
    WANG Liang
    GAO Guo-dong
    DONG Xiu-zhen
    Chinese Journal of Biomedical Engineering, 2018, 27 (02) : 57 - 67
  • [7] Monotonicity-based electrical impedance tomography for lung imaging
    Zhou, Liangdong
    Harrach, Bastian
    Seo, Jin Keun
    INVERSE PROBLEMS, 2018, 34 (04)
  • [8] Feasibility study of imaging fast neural activity in retinal tissue using Electrical Impedance Tomography
    Zhu, Danyi
    Fang, Xiunan
    Eiber, Calvin
    Avery, James
    Holder, David
    McEwan, Alistair
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 529 - 532
  • [9] Single Cell Imaging Using Electrical Impedance Tomography
    Sun, Tao
    Tsuda, Soichiro
    Zauner, Klaus-Peter
    Morgan, Hywel
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 858 - 863
  • [10] Study on human brain impedance imaging using electrical impedance tomography
    Xu, GZ
    Dong, GY
    Yan, WL
    Yang, QX
    PROCEEDINGS OF THE FOURTH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS, 2000, : 378 - 380