Multi-criteria evaluation of wastewater treatment plant control strategies under uncertainty

被引:97
作者
Flores-Alsina, Xavier [1 ,2 ]
Rodriguez-Roda, Ignasi [1 ]
Sin, Guerkan [2 ]
Gernaey, Krist V. [2 ]
机构
[1] Univ Girona, Lab Chem & Environm Engn, Girona 17071, Spain
[2] Tech Univ Denmark, Dept Chem & Biochem Engn, Ctr BioProc Engn, DK-2800 Lyngby, Denmark
关键词
Wastewater treatment; Control; Benchmarking; Multi-criteria decision analysis; Uncertainty; Monte Carlo simulation;
D O I
10.1016/j.watres.2008.05.029
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The evaluation of activated sludge control strategies in wastewater treatment plants (WWTP) via mathematical modelling is a complex activity because several objectives; e.g. economic, environmental, technical and legal; must be taken into account at the same time, i.e. the evaluation of the alternatives is a multi-criteria problem. Activated sludge models are not well characterized and some of the parameters can present uncertainty, e.g. the influent fractions arriving to the facility and the effect of either temperature or toxic compounds on the kinetic parameters, having a strong influence in the model predictions used during the evaluation of the alternatives and affecting the resulting rank of preferences. Using a simplified version of the IWA Benchmark Simulation Model No. 2 as a case study, this article shows the variations in the decision making when the uncertainty in activated sludge model (ASM) parameters is either included or not during the evaluation of WWTP control strategies. This paper comprises two main sections. Firstly, there is the evaluation of six WWTP control strategies using multi-criteria decision analysis setting the ASM parameters at their default value. In the following section, the uncertainty is introduced, i.e. input uncertainty, which is characterized by probability distribution functions based on the available process knowledge. Next, Monte Carlo simulations are run to propagate input through the model and affect the different outcomes. Thus (i) the variation in the overall degree of satisfaction of the control objectives for the generated WWTP control strategies is quantified, (ii) the contributions of environmental, legal, technical and economic objectives to the existing variance are identified and finally (iii) the influence of the relative importance of the control objectives during the selection of alternatives is analyzed. The results show that the control strategies with an external carbon source reduce the output uncertainty in the criteria used to quantify the degree of satisfaction of environmental, technical and legal objectives, but increasing the economical costs and their variability as a trade-off. Also, it is shown how a preliminary selected alternative with cascade ammonium controller becomes less desirable when input uncertainty is included, having simpler alternatives more chance of success. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4485 / 4497
页数:13
相关论文
共 32 条
  • [1] [Anonymous], 1998, MULTIVARIABLE DATA A
  • [2] [Anonymous], 2007, P 7 INT IWA S SYST A
  • [3] Batstone DJ, 2002, 13 IWA
  • [4] WATER-QUALITY MODELING - A REVIEW OF THE ANALYSIS OF UNCERTAINTY
    BECK, MB
    [J]. WATER RESOURCES RESEARCH, 1987, 23 (08) : 1393 - 1442
  • [5] Belton V., 2002, INTEGRATED APPROACH, DOI [10.1007/978-1-4615-1495-4, DOI 10.1007/978-1-4615-1495-4_9]
  • [6] Assessment of WWTP design and upgrade options: balancing costs and risks of standards' exceedance
    Benedetti, L.
    Bixio, D.
    Vanrolleghem, P. A.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2006, 54 (6-7) : 371 - 378
  • [7] Extension of the IWA/COST simulation benchmark to include expert reasoning for system performance evaluation
    Comas, J.
    Rodriguez-Roda, I.
    Poch, M.
    Gernaey, K. V.
    Rosen, C.
    Jeppsson, U.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2006, 53 (4-5) : 331 - 339
  • [8] Copp B., 2002, The COST Simulation Benchmark-Description and Simulator Manual
  • [9] Application of multivariable statistical techniques in plant-wide WWTP control strategies analysis
    Flores, X.
    Comas, J.
    Roda, I. R.
    Jimenez, L.
    Gernaey, K. V.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2007, 56 (06) : 75 - 83
  • [10] Selection of the activated sludge configuration during the conceptual design of activated sludge plants using multicriteria analysis
    Flores, X
    Bonmatì, A
    Poch, M
    Rodríguez-Roda, I
    Bañares-Alcántara, R
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (10) : 3556 - 3566