Event reconstruction in NEXT using the ML-EM algorithm

被引:2
|
作者
Simon, A. [1 ]
Ferrario, P. [1 ]
Izmaylov, A. [1 ]
机构
[1] UV, CSIC, Inst Fis Corpuscular, Valencia, Spain
关键词
NEXT; ML-EM; neutrinoless double beta decay;
D O I
10.1016/j.nuclphysbps.2015.10.010
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The NEXT collaboration aims to find the neutrinoless double beta decay in Xe-136. The rareness of this decay demands an exceptional background rejection. This can be obtained with an excellent energy resolution, which has been already demonstrated in the NEXT prototypes. In addition to this, the beta beta 0 nu decay in gas produces a characteristic topological signal which could be an extremely useful extra handle to avoid background events. The need for a satisfactory topology reconstruction has led the NEXT Collaboration to implement the Maximum Likelihood Expectation Maximization method (ML-EM) in the data processing scheme. ML-EM is a generic iterative algorithm for many kinds of inverse problems. Although this method is well known in medical imaging and has been used widely in Positron Emission Tomography, it has never been applied to a time projection chamber. First results and studies of the performance of the method will be presented in this poster.
引用
收藏
页码:2624 / 2626
页数:3
相关论文
共 50 条
  • [41] NOISE AND SPATIAL-RESOLUTION PROPERTIES OF ML-EM RECONSTRUCTED IMAGES
    WILSON, DW
    TSUI, BMW
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P20 - P20
  • [42] Time of Flight Ultrasonic CT Based on ML-EM for Wooden Pillars
    Fan, Honghui
    Yanagida, Hirotaka
    Guo, Shuqing
    Takahashi, Tatsuhisa
    Tamura, Yasutaka
    Adachi, Kazunari
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1495 - +
  • [43] ModPET - A compact PET system employing modular gamma cameras, maximum-likelihood event-parameter estimation, and list-mode ML-EM reconstruction
    Moore, Stephen
    Barrett, Harrison
    Furenlid, Lars
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [44] Statistical iterative pattern generation in volumetric additive manufacturing based on ML-EM
    Chen, Tianhang
    Li, Haifeng
    Liu, Xu
    OPTICS COMMUNICATIONS, 2023, 537
  • [45] Evaluation of OS-EM vs ML-EM for 1D, 2D and fully 3D SPECT reconstruction
    Kamphuis, C
    Beekman, FJ
    Viergever, MA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 2018 - 2024
  • [46] Cross-validation stopping rule for ML-EM reconstruction of dynamic PET series: Effect on image quality and quantitative accuracy
    Selivanov, VV
    Lapointe, D
    Bentourkia, M
    Lecomte, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 883 - 889
  • [47] PET image resolution recovery using PSF-based ML-EM deconvolution with blob-based list-mode TOF reconstruction
    Zhang, Bin
    Olivier, Patrick
    Lorman, Benjamin
    Tung, Chi-hua
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [48] Determination of optimal collimation parameters for a rotating slat collimator system: a system matrix method using ML-EM
    Boisson, F.
    Bekaert, V.
    Brasse, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06): : 2302 - 2318
  • [49] Cross-validation stopping rule for ML-EM reconstruction of dynamic PET series: Effect on image quality and quantitative accuracy
    Selivanov, V
    Lapointe, D
    Bentourkia, M
    Lecomte, R
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1433 - 1437
  • [50] Evaluation of OS-EM vs. ML-EM for 1D, 2D and fully 3D SPECT reconstruction
    Kamphuis, Chris
    Beekman, Freek J.
    Viergever, Max A.
    IEEE Transactions on Nuclear Science, 1996, 43 (3 pt 2): : 2018 - 2024