Powder mixed-EDM for potential biomedical applications: A critical review

被引:79
作者
Al-Amin, Md [1 ]
Rani, Ahmad Majdi Abdul [1 ]
Aliyu, Abdul Azeez Abdu [2 ]
Razak, Muhammad Al'Hapis Abdul [3 ]
Hastuty, Sri [4 ]
Bryant, Michael G. [5 ]
机构
[1] Univ Teknol PETRONAS, Dept Mech Engn, Bandar Seri Iskandar 32610, Perak, Malaysia
[2] Bayero Univ Kano, Dept Mech Engn, Kano, Nigeria
[3] Univ Kuala Lumpur, Dept Mech Engn, Malaysian Spanish Inst, Kulim, Malaysia
[4] Univ Pertamina, Dept Mech Engn, Kota Jakarta Selatan, Indonesia
[5] Univ Leeds, Sch Mech Engn, Leeds, W Yorkshire, England
关键词
Electro-discharge; electro-deposition; biomedical; biomaterials; coating; compounds; modification; manufacturing; powders; properties; 316L STAINLESS-STEEL; BIODEGRADABLE MAGNESIUM ALLOYS; DISCHARGE MACHINING PARAMETERS; MATERIAL REMOVAL RATE; SURFACE MODIFICATION; IN-VITRO; CORROSION-RESISTANCE; TITANIUM CARBIDE; HYDROXYAPATITE COATINGS; MECHANICAL-PROPERTIES;
D O I
10.1080/10426914.2020.1779939
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Powder mixed-electro discharge machining (PM-EDM) is a new emerging trend in research on electro-thermal process that can simultaneously shape and deposit a coating on the surface of the workpiece. PM-EDM is a hybridized form of EDM in which metallic powders are amalgamated in dielectric liquid to enhance both the machined surface condition and machining performance. Migration of materials on the cutting surface occurs by melting and chemical reactions during the operation from both the electrodes and metallic powders. 316L stainless steel, Ti-based alloys, Co-Mo-Cr-based alloys, magnesium and magnesium-based alloys are commonly utilized in manufacturing biomedical devices. These biomaterials, however, release toxic particles due to corrosion, wear, tear, and tiredness of the joint replacements through repeated loads and relative movements. Surfaces of bio-implants made from these biomaterials are therefore protected using bioactive and biocompatible coating. Several methods of deposition are used for coating purposes which have both advantage and drawback. This study proposes that the PM-EDM coating enhances the biomaterials' mechanical characteristics, surface morphology, and topography. Through reflecting critical and analytical concerns, this review focuses extensively on the current progress of the PM-EDM process. Moreover, following various research initiatives, this paper outlines the critical challenges and future research scopes.
引用
收藏
页码:1789 / 1811
页数:23
相关论文
共 232 条
  • [1] A review on current research trends in electrical discharge machining (EDM)
    Abbas, Norliana Mohd
    Solomon, Darius G.
    Bahari, Md. Fuad
    [J]. INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2007, 47 (7-8) : 1214 - 1228
  • [2] Nanosized Controlled Surface Pretreatment of Biometallic Alloy 316L Stainless Steel
    Abdel-Fattah, Tarek M.
    Loftis, Derek
    Mahapatro, Anil
    [J]. JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2011, 7 (06) : 794 - 800
  • [3] Machined Surface Quality in Nano Aluminum Mixed Electrical Discharge Machining
    Abdul-Rani, A. M.
    Nanimina, A. M.
    Ginta, T. L.
    Razak, M. A.
    [J]. INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS PROCESSING AND MANUFACTURING (SMPM 2017), 2016, 7 : 510 - 517
  • [4] Improving EDM Process on AZ31 Magnesium Alloy towards Sustainable Biodegradable Implant Manufacturing
    Abdul-Rani, A. M.
    Razak, M. A.
    Littlefair, G.
    Gibson, I.
    Nanimina, A. M.
    [J]. INTERNATIONAL CONFERENCE ON SUSTAINABLE MATERIALS PROCESSING AND MANUFACTURING (SMPM 2017), 2016, 7 : 504 - 509
  • [5] Enhancing Surface Quality of Zr-Cu-Ni-Ti-Be through Hydroxyapatite Mixed EDM for Potential Orthopedic Application
    Abdul-Rani, Ahmad Majdi
    Aliyu, Abdul Azeez Abdu
    Hastuty, Sri
    Ginta, Turnad Lenggo
    Rao, T. V. V. L. N.
    Ali, Sadaqat
    [J]. 6TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY 2018: WORLD ENGINEERING SCIENCE & TECHNOLOGY CONGRESS (ESTCON), 2018, 2035
  • [6] Advanced Electric Discharge Machining of Stainless Steels: Assessment of the State of the Art, Gaps and Future Prospect
    Abu Qudeiri, Jaber E.
    Saleh, Ahmad
    Ziout, Aiman
    Mourad, Abdel-Hamid I.
    Abidi, Mustufa Haider
    Elkaseer, Ahmed
    [J]. MATERIALS, 2019, 12 (06)
  • [7] CARBON FIBER-REINFORCED CARBON AS A POTENTIAL IMPLANT MATERIAL
    ADAMS, D
    WILLIAMS, DF
    HILL, J
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1978, 12 (01): : 35 - 42
  • [8] Biodegradable magnesium alloys for orthopaedic applications: A review on corrosion, biocompatibility and surface modifications
    Agarwal, Sankalp
    Curtin, James
    Duffy, Brendan
    Jaiswal, Swarna
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 68 : 948 - 963
  • [9] Ahmed A, 2015, AIRFIELD AND HIGHWAY PAVEMENTS 2015: INNOVATIVE AND COST-EFFECTIVE PAVEMENTS FOR A SUSTAINABLE FUTURE, P1
  • [10] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170