Measurement Error in Estimates of Sprint Velocity from a Laser Displacement Measurement Device

被引:39
作者
Bezodis, N. E. [1 ,2 ]
Salo, A. I. T. [2 ]
Trewartha, G. [2 ]
机构
[1] St Marys Univ Coll, Sch Sport Hlth & Appl Sci, London TW1 4SX, England
[2] Univ Bath, Bath BA2 7AY, Avon, England
关键词
athletics; biomechanics; methods; performance; running; sprinting; PERFORMANCE; PHASE; POWER; LIMB;
D O I
10.1055/s-0031-1301313
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study aimed to determine the measurement error associated with estimates of velocity from a laser-based device during different phases of a maximal athletic sprint. Laser-based displacement data were obtained from 10 sprinters completing a total of 89 sprints and were fitted with a fifth-order polynomial function which was differentiated to obtain instantaneous velocity data. These velocity estimates were compared against criterion high-speed video velocities at either 1, 5, 10, 30 or 50 m using a Bland-Altman analysis to assess bias and random error. Bias was highest at 1 m (+0.41 m/s) and tended to decrease as the measurement distance increased, with values less than +0.10 m/s at 30 and 50 m. Random error was more consistent between distances, and reached a minimum value (+/-0.11 m/s) at 10 m. Laser devices off er a potentially useful time-efficient tool for assessing between-subject or between-session performance from the mid-acceleration and maximum velocity phases (i.e., at 10 m and beyond), although only differences exceeding 0.22-0.30 m/s should be considered genuine. However, laser data should not be used during the first 5 m of a sprint, and are likely of limited use for assessing within-subject variation in performance during a single session.
引用
收藏
页码:439 / 444
页数:6
相关论文
共 26 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   Modeling the energetics of 100-m running by using speed curves of world champions [J].
Arsac, LM ;
Locatelli, E .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 92 (05) :1781-1788
[3]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[4]  
Berthoin S, 2001, J STRENGTH COND RES, V15, P75
[5]   Lower-limb mechanics during the support phase of maximum-velocity sprint running [J].
Bezodis, Ian N. ;
Kerwin, David G. ;
Salo, Aki I. T. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (04) :707-715
[6]   Choice of sprint start performance measure affects the performance-based ranking within a group of sprinters: which is the most appropriate measure? [J].
Bezodis, Neil E. ;
Salo, Aki I. T. ;
Trewartha, Grant .
SPORTS BIOMECHANICS, 2010, 9 (04) :258-269
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]  
Chelly SM, 2001, MED SCI SPORT EXER, V33, P326
[9]   A low-cost accurate speed-tracking system for supporting sprint coaching [J].
Cheng, L. ;
Tan, H. ;
Kuntze, G. ;
Bezodis, I. N. ;
Hailes, S. ;
Kerwin, D. G. ;
Wilson, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2010, 224 (P2) :167-179
[10]   Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters [J].
de Leva, P .
JOURNAL OF BIOMECHANICS, 1996, 29 (09) :1223-1230