An evaluation of the present status of quality assurance program implementation in digital mammography facilities in a developing country

被引:7
作者
Gonzalez-Ruiz, Abraham [1 ]
Sanchez Mendoza, Helen Irais [2 ]
Santos Cuevas, Clara Leticia [3 ]
Isidro-Ortega, Frank J. [3 ]
Flores Estrada, Jaime [1 ]
Victoria Dominguez-Garcia, Ma [1 ]
Flores-Merino, Miriam, V [1 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Quim, Toluca 50180, Estado De Mexic, Mexico
[2] Inst Nacl Salud Publ, Ciudad De Mexico 14080, Mexico
[3] Inst Nacl Invest Nucl, Ocoyoacac 52750, Estado De Mexic, Mexico
关键词
quality assurance program; quality control tests; mammography; quality image; IMAGE QUALITY; AMERICAN-COLLEGE; BREAST-CANCER; SYSTEMS; IMPACT;
D O I
10.1088/1361-6498/aca0fe
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Quality assurance program (QAP) implementation in mammography is a key aspect to guarantee the acquisition of -quality images and, thus, an opportune diagnosis of breast cancer. A QAP involves planned and systematic actions, such as quality control (QC) tests that will produce consistently high-quality images, while considering low radiation exposure for stakeholders. Currently, there is poor evidence of the current QAP implementation status in developing countries, particularly in Latin America. In this work, 47 Mexican digital mammography facilities were evaluated in terms of their QAP implementation's current status during the period October 2021 to April 2022. A survey of three key indicators of compliance/non-compliance with QAPs was carried out. Also, 17 QC test parameters were assessed in all mammography units according to an international framework. The Kruskal-Wallis test, McNemar test, and Spearman correlation were used to identify the significant correlation between the QC tests and QAP indicators. Statistical analysis showed a significant positive correlation between the QAP indicators and QC parameters that were evaluated, especially associated with an increase in image quality. Almost 90% of the facilities evaluated failed in some QAP indicators, and only 44.68% of the facilities had an updated and current QAP implemented. Successful QAP implementation directly impacted on the QC mammography test results, particularly in terms of image quality, thus conditioning a successful mammography acquisition chain. The results obtained in this work suggest that better regulations need to be implemented to guarantee QAP surveillance, which could mean an increase in opportune diagnosis and management of breast cancer, with improved radiological safety for patients and occupational exposure personnel.
引用
收藏
页数:11
相关论文
共 37 条
  • [21] Quality assessment of cold chain storage facilities for regulatory and quality management compliance in a developing country context
    Chukwu, Otuto Amarauche
    Adibe, Maxwell
    INTERNATIONAL JOURNAL OF HEALTH PLANNING AND MANAGEMENT, 2022, 37 (02) : 930 - 943
  • [22] CACTUS: A Digital Tool for Quality Assurance, Education and Evaluation in Surgical Pathology
    Aksac, Alper
    Demetrick, Douglas J.
    Box, Adrian
    DiFrancesco, Lisa
    Minoo, Parham
    Ozyer, Tansel
    Rokne, Jon
    Alhajj, Reda
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (04) : 470 - 481
  • [23] Surgical site infections in pediatric spinal surgery after implementation of a quality assurance program
    Hammoor, Bradley
    Matsumoto, Hiroko
    Marciano, Gerard
    Dziesinski, Lucas
    Wang, Kevin
    Roye, Benjamin D.
    Roye, David P.
    Vitale, Michael G.
    SPINE DEFORMITY, 2021, 9 (01) : 125 - 133
  • [24] Evaluation of an automated grid artifact detection system for quality control in digital mammography
    MacLellan, Christopher J.
    Layman, Rick R.
    Geiser, William
    Gress, Dustin A.
    Jones, A. Kyle
    MEDICAL PHYSICS, 2019, 46 (08) : 3442 - 3450
  • [25] Digital slides: Present status of a tool for consultation, teaching, and quality control in pathology
    Rocha, Rafael
    Vassallo, Jose
    Soares, Fernando
    Miller, Keith
    Gobbi, Helenice
    PATHOLOGY RESEARCH AND PRACTICE, 2009, 205 (11) : 735 - 741
  • [26] Reliable quality assurance of X-ray mammography scanner by evaluation the standard mammography phantom image using an interpretable deep learning model
    Oh, Jang-Hoon
    Kim, Hyug-Gi
    Lee, Kyung Mi
    Ryu, Chang-Woo
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 154
  • [27] Developing a novel phantom for image quality evaluation in digital radiography
    Yalcin, Asena
    Olgar, Turan
    RADIATION PHYSICS AND CHEMISTRY, 2024, 222
  • [28] Evaluation of low-energy contrast-enhanced spectral mammography images by comparing them to full-field digital mammography using EUREF image quality criteria
    U. C. Lalji
    C. R. L. P. N. Jeukens
    I. Houben
    P. J. Nelemans
    R. E. van Engen
    E. van Wylick
    R. G. H. Beets-Tan
    J. E. Wildberger
    L. E. Paulis
    M. B. I. Lobbes
    European Radiology, 2015, 25 : 2813 - 2820
  • [29] Evaluation of low-energy contrast-enhanced spectral mammography images by comparing them to full-field digital mammography using EUREF image quality criteria
    Lalji, U. C.
    Jeukens, C. R. L. P. N.
    Houben, I.
    Nelemans, P. J.
    van Engen, R. E.
    van Wylick, E.
    Beets-Tan, R. G. H.
    Wildberger, J. E.
    Paulis, L. E.
    Lobbes, M. B. I.
    EUROPEAN RADIOLOGY, 2015, 25 (10) : 2813 - 2820
  • [30] Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality
    Osteras, Bjorn Helge
    Skaane, Per
    Gullien, Randi
    Martinsen, Anne Catrine Traegde
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)