An evaluation of the present status of quality assurance program implementation in digital mammography facilities in a developing country

被引:7
作者
Gonzalez-Ruiz, Abraham [1 ]
Sanchez Mendoza, Helen Irais [2 ]
Santos Cuevas, Clara Leticia [3 ]
Isidro-Ortega, Frank J. [3 ]
Flores Estrada, Jaime [1 ]
Victoria Dominguez-Garcia, Ma [1 ]
Flores-Merino, Miriam, V [1 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Quim, Toluca 50180, Estado De Mexic, Mexico
[2] Inst Nacl Salud Publ, Ciudad De Mexico 14080, Mexico
[3] Inst Nacl Invest Nucl, Ocoyoacac 52750, Estado De Mexic, Mexico
关键词
quality assurance program; quality control tests; mammography; quality image; IMAGE QUALITY; AMERICAN-COLLEGE; BREAST-CANCER; SYSTEMS; IMPACT;
D O I
10.1088/1361-6498/aca0fe
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Quality assurance program (QAP) implementation in mammography is a key aspect to guarantee the acquisition of -quality images and, thus, an opportune diagnosis of breast cancer. A QAP involves planned and systematic actions, such as quality control (QC) tests that will produce consistently high-quality images, while considering low radiation exposure for stakeholders. Currently, there is poor evidence of the current QAP implementation status in developing countries, particularly in Latin America. In this work, 47 Mexican digital mammography facilities were evaluated in terms of their QAP implementation's current status during the period October 2021 to April 2022. A survey of three key indicators of compliance/non-compliance with QAPs was carried out. Also, 17 QC test parameters were assessed in all mammography units according to an international framework. The Kruskal-Wallis test, McNemar test, and Spearman correlation were used to identify the significant correlation between the QC tests and QAP indicators. Statistical analysis showed a significant positive correlation between the QAP indicators and QC parameters that were evaluated, especially associated with an increase in image quality. Almost 90% of the facilities evaluated failed in some QAP indicators, and only 44.68% of the facilities had an updated and current QAP implemented. Successful QAP implementation directly impacted on the QC mammography test results, particularly in terms of image quality, thus conditioning a successful mammography acquisition chain. The results obtained in this work suggest that better regulations need to be implemented to guarantee QAP surveillance, which could mean an increase in opportune diagnosis and management of breast cancer, with improved radiological safety for patients and occupational exposure personnel.
引用
收藏
页数:11
相关论文
共 37 条
  • [1] Interim recommendations for a digital mammography quality assurance program
    I. D. McLean
    J. C. P. Heggie
    J. Herley
    F. J. Thomson
    R. K. Grewal
    Australasian Physics & Engineering Sciences in Medicine, 2007, 30 : 65 - 100
  • [2] Interim recommendations for a digital mammography quality assurance program
    McLean, I. D.
    Heggie, J. C. P.
    Herley, J.
    Thomson, F. J.
    Grewal, R. K.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (02) : 65 - 100
  • [3] Recommendations for a mammography quality assurance program
    Craig A.R.
    Heggie J.C.P.
    McLean I.D.
    Coakley K.S.
    Nicoll J.J.
    Australasian Physics & Engineering Sciences in Medicine, 2001, 24 (3): : 107 - 131
  • [4] Position paper: recommendations for a digital mammography quality assurance program V4.0
    Heggie, J. C. P.
    Barnes, P.
    Cartwright, L.
    Diffey, J.
    Tse, J.
    Herley, J.
    McLean, I. D.
    Thomson, F. J.
    Grewal, R. K.
    Collins, L. T.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (03) : 491 - 543
  • [5] Position paper: recommendations for a digital mammography quality assurance program V4.0
    J. C. P. Heggie
    P. Barnes
    L. Cartwright
    J. Diffey
    J. Tse
    J. Herley
    I. D. McLean
    F. J. Thomson
    R. K. Grewal
    L. T. Collins
    Australasian Physical & Engineering Sciences in Medicine, 2017, 40 : 491 - 543
  • [6] Implementation of a Clinical Quality Control Program in a Mammography Screening Service of Brazil
    Prioli De Souza Sabino, Silvia Maria
    Silva, Thiago Buosi
    Uema Watanabe, Anapaula Hidemi
    Syrjanen, Kari
    Carvalho, Andre Lopes
    Mauad, Edmundo Carvalho
    ANTICANCER RESEARCH, 2014, 34 (09) : 5057 - 5065
  • [7] Dose sensitivity of three phantoms used for quality assurance in digital mammography
    Figl, M.
    Semturs, F.
    Kaar, M.
    Hoffmann, R.
    Kaldarar, H.
    Homolka, P.
    Mostbeck, G.
    Scholz, B.
    Hummel, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (02) : N13 - N23
  • [8] An evaluation of the current status of quality assurance program in MRI: A multicenter study
    Lopez, D. Vasquez
    Mendoza, H. I. Sanchez
    Alcaraz, E. H. Pasaye
    Santos-Cuevas, C. L.
    Gonzalez-Ruiz, A.
    RADIOGRAPHY, 2025, 31 (03)
  • [9] A harmonized quality control program for digital mammography
    Yaffe, Martin
    Mawdsley, Gordon
    Bloomquist, Aili
    DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 585 - 592
  • [10] Automatic and standardized quality assurance of digital mammography and tomosynthesis with deep convolutional neural networks
    Hejduk, Patryk
    Sexauer, Raphael
    Ruppert, Carlotta
    Borkowski, Karol
    Unkelbach, Jan
    Schmidt, Noemi
    INSIGHTS INTO IMAGING, 2023, 14 (01)