A biomimetic potentiometric sensor using molecularly imprinted polymer for the cetirizine assay in tablets and biological fluids

被引:68
|
作者
Javanbakht, Mehran [1 ]
Fard, Solmaz Eynollahi [2 ,3 ]
Abdouss, Majid [1 ]
Mohammadi, Ali [4 ,5 ]
Ganjali, Mohammad Reza [3 ]
Norouzi, Parviz [3 ]
Safaraliee, Leila [2 ,3 ]
机构
[1] Amirkabir Univ Technol, Dept Chem, Tehran, Iran
[2] Young Researchers Club Islamic Azad Univ, Tehran, Iran
[3] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[4] Med Sci Univ Tehran, Sch Pharm, Dept Drug & Food Control, Tehran, Iran
[5] Med Sci Univ Tehran, Med Nanotechnol Res Ctr, Tehran, Iran
关键词
molecularly imprinted polymer; potentiometric sensor; biomimetic sensor; cetirizine; biological fluids; tablets;
D O I
10.1002/elan.200804284
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Despite the increasing number of applications of molecularly imprinted polymers (MIPs) in analytical chemistry, the construction of a biomimetic potentiometric sensor remains still challenging. In this work, a biomimetic potentiometric sensor, based on a non-covalent imprinted polymer was fabricated for the recognition and determination of cetirizine. The MIP was synthesized by precipitation polymerization, using cetirizine dihydrochloride as a template molecule, methacrylic acid (MAA) as a functional monomer and ethylene glycol dimethacrylate (EGDMA) as a cross linking agent. The sensor showed high selectivity and a sensitive response to the template in aqueous system. The MIP-modified electrode exhibited Nernstian response (28.0 +/- 0.9 mV/decade) in a wide concentration range of 1.0 x 10(-6) to 1.0 x 10(-2) M with a lower detection limit of 7.0 x 10(-7) M. The electrode has response time of ca. 20 s, high performance, high sensitivity, and good long term stability (more than 5 months). The method was satisfactory and used to the cetirizine assay in tablets and biological fluids.
引用
收藏
页码:2023 / 2030
页数:8
相关论文
共 50 条
  • [1] Molecularly imprinted polymer based potentiometric sensor for the determination of hydroxyzine in tablets and biological fluids
    Javanbakht, Mehran
    Fard, Solmaz Eynollahi
    Mohammadi, Ali
    Abdouss, Majid
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Safaraliee, Leila
    ANALYTICA CHIMICA ACTA, 2008, 612 (01) : 65 - 74
  • [2] A biomimetic potentiometric sensor based on molecularly imprinted polymer for the determination of memantine in tablets
    Arvand, Majid
    Samie, Hedyeh Asadi
    DRUG TESTING AND ANALYSIS, 2013, 5 (06) : 461 - 467
  • [3] Voltammetric Determination of Pindolol in Biological Fluids Using Molecularly Imprinted Polymer Based Biomimetic Sensor
    Tadi, Kiran Kumar
    Motghare, Ramani V.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (07) : B286 - B292
  • [4] Molecularly imprinted polymer (biomimetic) based potentiometric sensor for atrazine
    Prasad, K.
    Prathish, K. P.
    Gladis, J. Mary
    Naidu, G. R. K.
    Rao, T. Prasada
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (01) : 65 - 70
  • [5] Synthesis by Precipitation Polymerization of a Molecularly Imprinted Polymer Membrane for the Potentiometric Determination of Sertraline in Tablets and Biological Fluids
    Arvand, Majid
    Hashemi, Masoumeh
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (03) : 392 - 402
  • [6] Biomimetic Sensor Potentiometric System for Doxycycline Antibiotic Using a Molecularly Imprinted Polymer as an Artificial Recognition Element
    Kamel, Ayman H.
    Moreira, Felismina T. C.
    Sales, M. Goreti F.
    SENSOR LETTERS, 2011, 9 (05) : 1654 - 1660
  • [7] A Biomimetic Potentiometric Membrane Sensor using Molecularly Imprinted Nano-Polymer for Furosemide Drug Analysis
    Ganjali, Mohammad Reza
    Jamshidpour, Tahereh
    Rezapour, Morteza
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (10): : 1467 - 1481
  • [8] Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor
    Kou, Li-Juan
    Liang, Rong-Ning
    Wang, Xue-Wei
    Chen, Yan
    Qin, Wei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4931 - 4936
  • [9] Potentiometric sensor for determination of neutral bisphenol A using a molecularly imprinted polymer as a receptor
    Li-Juan Kou
    Rong-Ning Liang
    Xue-Wei Wang
    Yan Chen
    Wei Qin
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4931 - 4936
  • [10] Man-Tailored Biomimetic Sensor of Molecularly Imprinted Materials for the Potentiometric Measurement of Rivastigmine in Tablets and Biological Fluids and Employing the Taguchi Optimization Methodology to Optimize the MIP-Based Membranes
    Arvand, Majid
    Fallahi, Parisa
    ELECTROANALYSIS, 2012, 24 (09) : 1852 - 1863