Non-Rigid Event-by-Event Continuous Respiratory Motion Compensated List-Mode Reconstruction for PET

被引:27
作者
Chan, Chung [1 ,2 ]
Onofrey, John [1 ]
Jian, Yiqiang [1 ,3 ]
Germino, Mary [1 ,4 ]
Papademetris, Xenophon [1 ]
Carson, Richard E. [5 ]
Liu, Chi [1 ]
机构
[1] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT 06520 USA
[2] Toshiba Med Res Inst USA Inc, Vernon Hills, IL 60061 USA
[3] GE Healthcare, Waukesha, WI 53188 USA
[4] Regeneron Pharmaceut Inc, Tarrytown, NY 10591 USA
[5] Yale Univ, Dept Radiol & Biomed Imaging, Yale PET Ctr, New Haven, CT 06520 USA
关键词
Event-by-event motion correction; image reconstruction; list-mode reconstruction; non-rigid motion correction; positron emission tomography (PET); IMAGE-RECONSTRUCTION; IMPACT; QUANTIFICATION; IMPLEMENTATION; GATE;
D O I
10.1109/TMI.2017.2761756
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Respiratory motion during positron emission tomography (PET)/computed tomography (CT) imaging can cause significant image blurring and underestimation of tracer concentration for both static and dynamic studies. In this paper, with the aim to eliminate both intra-cycle and inter-cycle motions, and apply to dynamic imaging, we developed a non-rigid event-by-event (NR-EBE) respiratory motion-compensated list-mode reconstruction algorithm. The proposed method consists of two components: the first component estimates a continuous non-rigid motion field of the internal organs using the internal-external motion correlation. This continuous motion field is then incorporated into the second component, non-rigid MOLAR (NR-MOLAR) reconstruction algorithm to deform the system matrix to the reference location where the attenuation CT is acquired. The point spread function (PSF) and time-of-flight (TOF) kernels in NR-MOLAR are incorporated in the system matrix calculation, and therefore are also deformed according to motion. We first validated NR-MOLAR using a XCAT phantom with a simulated respiratory motion. NR-EBE motion-compensated image reconstruction using both the components was then validated on three human studies injected with F-18-FPDTBZ and one with F-18-fluorodeoxyglucose (FDG) tracers. The human results were compared with conventional non-rigid motion correction using discrete motion field (NR-discrete, one motion field per gate) and a previously proposed rigid EBE motion-compensated image reconstruction (R-EBE) that was designed to correct for rigid motion on a target lesion/organ. The XCAT results demonstrated that NR-MOLAR incorporating both PSF and TOF kernels effectively corrected for non-rigid motion. The F-18-FPDTBZ studies showed that NR-EBE out-performed NR-Discrete, and yielded comparable results with R-EBE on target organs while yielding superior image quality in other regions. The FDG study showed that NR-EBE clearly improved the visibility of multiple moving lesions in the liver where some of them could not be discerned in other reconstructions, in addition to improving quantification. These results show that NR-EBE motion-compensated image reconstruction appears to be a promising tool for lesion detection and quantification when imaging thoracic and abdominal regions using PET.
引用
收藏
页码:504 / 515
页数:12
相关论文
共 45 条
[1]   A GPU-Accelerated Implementation of the MOLAR PET Reconstruction Package [J].
Barker, W. Craig ;
Thada, Shanthalaxmi ;
Dieckmann, William .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :4114-4119
[2]   Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation [J].
Bousse, Alexandre ;
Manber, Richard ;
Holman, Beverley F. ;
Atkinson, David ;
Arridge, Simon ;
Ourselin, Sebastien ;
Hutton, Brian F. ;
Thielemans, Kris .
MEDICAL PHYSICS, 2017, 44 (06) :2379-2390
[3]   Maximum-Likelihood Joint Image Reconstruction/Motion Estimation in Attenuation-Corrected Respiratory Gated PET/CT Using a Single Attenuation Map [J].
Bousse, Alexandre ;
Bertolli, Ottavia ;
Atkinson, David ;
Arridge, Simon ;
Ourselin, Sebastien ;
Hutton, Brian F. ;
Thielemans, Kris .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (01) :217-228
[4]   Abdominal organ motion measured using 4D CT [J].
Brandner, Edward D. ;
Wu, Andrew ;
Chen, Hungcheng ;
Heron, Dwight ;
Kalnicki, Shalom ;
Komanduri, Krishna ;
Gerszten, Kristina ;
Burton, Steve ;
Ahmed, Irfan ;
Shou, Zhenyu .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :554-560
[5]   Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT [J].
Carson, RE ;
Barker, WC ;
Liow, JS ;
Johnson, CA .
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, :3281-3285
[6]   End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system [J].
Chan, Chung ;
Harris, Mark ;
Le, Max ;
Biondi, James ;
Grobshtein, Yariv ;
Liu, Yi-Hwa ;
Sinusas, Albert J. ;
Liu, Chi .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (20) :6267-6287
[7]   Event-by-event respiratory motion correction for PET with 3D internal-1D external motion correlation [J].
Chan, Chung ;
Jin, Xiao ;
Fung, Edward K. ;
Naganawa, Mika ;
Mulnix, Tim ;
Carson, Richard E. ;
Liu, Chi .
MEDICAL PHYSICS, 2013, 40 (11)
[8]   MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI [J].
Chun, Se Young ;
Reese, Timothy G. ;
Ouyang, Jinsong ;
Guerin, Bastien ;
Catana, Ciprian ;
Zhu, Xuping ;
Alpert, Nathaniel M. ;
El Fakhri, Georges .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) :1284-1291
[9]   Lung motion correction on respiratory gated 3-D PET/CT images [J].
Dawood, M ;
Lang, N ;
Jiang, XY ;
Schäfers, KP .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (04) :476-485
[10]   Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes [J].
Dawood, Mohammad ;
Buether, Florian ;
Lang, Norbert ;
Schober, Otmar ;
Schaefers, Klaus P. .
MEDICAL PHYSICS, 2007, 34 (07) :3067-3076