Comparison of rectal dose-volume constraints for IMRT prostate treatment planning

被引:4
|
作者
Odrazka, K [1 ]
Zouhar, M [1 ]
Petera, J [1 ]
Vaculikova, M [1 ]
Dolezel, M [1 ]
Vosmik, M [1 ]
Tucek, P [1 ]
机构
[1] Charles Univ Prague, Fac Med Hradec Kralove, Univ Hosp Hradec Kralove, Dept Radiotherapy & Oncol, CZ-50005 Hradec Kralove, Czech Republic
关键词
treatment planning; optimization; tissue response factors; dose-volume analysis;
D O I
10.1016/S1120-1797(05)80001-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this paper is to compare different sets of rectal dose-volume constraints and to develop input criteria for the intensity-modulated radiation therapy (IMRT) of prostate cancer. The IMRT treatment plans were created using Varian planning system (CadPlan with Helios module) for ten patients with localized prostate cancer (isocenter dose 78 Gy). The posterior portion of rectum was contoured as an extra volume (help volume). Three sets of input parameters for rectum with gradually increasing priorities (25-50-75-90) were designed for the inverse treatment planning: 1. dose-volume constraints allowing no more than 50, 40, 20, and 10% of the rectum volume be irradiated to 50, 60, 70, and 75 Gy, respectively-volume-based plans, priorities 25-90 (V25-90 plans); 2. maximum dose constraint of 74.1 Gy for rectum - plans with limited maximum rectal dose, priorities 25-90 (M25-90 plans); 3. maximum dose constraint of 50 Gy for the help volume - plans with limited maximum dose for the help volume, priorities 25-90 (H25-90 plans). Dose homogeneity in the planning target volume (PTV) and the rectal volumes (RV) irradiated to 50, 60, 70, and 75 Gy (RV 50-75 Gy) were recorded. Rectum sparing improved for all the plans with increasing priority. While the M plans had the lowest RV 75 Gy values, the H plans gave the minimum RV 50-70 Gy values. Plans were considered acceptable if at least 98% of the PTV was treated to 95% of the prescribed dose. In particular plan groups, the V75, M75, and H50 plans, together with the V50 + M75 and H50 + M75 combined plans, satisfied this condition and yielded the lowest rectal doses. The H50 + M75 combined plan allowed optimal sparing of rectum (RV 50 Gy 51.6%, RV 60 Gy 38.5%, RV 70 Gy 26.0%, and RV 75 Gy 9.1%, respectively). An optimal set of dose-based rectal constraints (maximum rectal dose 74.1 Gy, maximum help volume dose 50 Gy) has been developed for Varian planning software. These parameters will constitute a starting point for the prostate IMRT plan optimization.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 50 条
  • [31] DOSE-VOLUME DISTRIBUTIONS - A NEW APPROACH TO DOSE-VOLUME HISTOGRAMS IN 3-DIMENSIONAL TREATMENT PLANNING
    NIEMIERKO, A
    GOITEIN, M
    MEDICAL PHYSICS, 1994, 21 (01) : 3 - 11
  • [32] Comparison of rectal dose-wall histograms and dose-volume histograms in predicting rectal grade toxicity after prostate cancer radiotherapy
    Johnson, JL
    Cheung, R
    Dong, L
    Tucker, SL
    de Crevoisier, R
    Kuban, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S207 - S207
  • [33] Incorporating Explicit Dose-Volume Constraints in Deep Learning Improves Prediction of Deliverable Dose Distributions for Prostate VMAT Planning
    Willems, S.
    Vandewinckele, L.
    Sterpin, E.
    Haustermans, K.
    Crijns, W.
    Maes, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E427 - E428
  • [34] A Comparison of Head and Neck IMRT Plans Optimized with Biologically Based Versus Dose-Volume Based Objectives in a Commercial Treatment Planning System
    Myint, K.
    Pyakuryal, A.
    Gopalakrishnan, M.
    Sathiaseelan, V.
    Mittal, B.
    MEDICAL PHYSICS, 2009, 36 (06) : 2644 - +
  • [35] Hybrid-Input-Output Algorithm for IMRT Optimization with Dose-Volume Histogram Constraints
    Mao, Y.
    Jia, X.
    Zarepisheh, M.
    Jiang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3847 - 3847
  • [36] Dose-Volume Histogram Based Inverse Treatment Planning Via Deep Reinforcement Learning in Intensity Modulated Radiation Therapy (IMRT) for Prostate Cancer
    Sprouts, D.
    Chi, Y.
    Shen, C.
    Jia, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E456 - E456
  • [37] Intensity-modulated radiation therapy (IMRT) for prostate cancer with the use of a rectal balloon for prostate immobilization: Acute toxicity and dose-volume analysis
    Teh, BS
    Mai, WY
    Uhl, BM
    Augspurger, ME
    Grant, WH
    Lu, HH
    Woo, SY
    Carpenter, LS
    Chiu, JK
    Butler, EB
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 705 - 712
  • [38] Conversion of dose-volume constraints to dose limits
    Dai, JR
    Zhu, YP
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (23): : 3927 - 3941
  • [39] Clinical implementation of dose-volume histogram predictions for organs-at-risk in IMRT planning
    Moore, K. L.
    Appenzoller, L. M.
    Tan, J.
    Michalski, J. M.
    Thorstad, W. L.
    Mutic, S.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [40] Key Anatomical Factors Influencing OAR Dose-Volume Distribution in Prostate IMRT Plans
    Yuan, L.
    Ge, Y.
    Li, T.
    Zhu, X.
    Yin, F.
    Wu, Q.
    MEDICAL PHYSICS, 2011, 38 (06)