Development and investigation of a magnetic resonance imaging-compatible microlens-based optical detector

被引:0
作者
Paar, Steffen [1 ]
Umathum, Reiner [1 ]
Jiang, Xiaoming [1 ]
Majer, Charles L. [1 ]
Peter, Joerg [1 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiol, D-69120 Heidelberg, Germany
关键词
optical imaging; magnetic resonance imaging; multimodal imaging; plenoptic camera system; TOMOGRAPHY;
D O I
10.1117/1.JBO.20.9.095007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A noncontact optical detector for in vivo imaging has been developed that is compatible with magnetic resonance imaging (MRI). The optical detector employs microlens arrays and might be classified as a plenoptic camera. As a resulting of its design, the detector possesses a slim thickness and is self-shielding against radio frequency (RF) pulses. For experimental investigation, a total of six optical detectors were arranged in a cylindrical fashion, with the imaged object positioned in the center of this assembly. A purposely designed RF volume resonator coil has been developed and is incorporated within the optical imaging system. The whole assembly was placed into the bore of a 1.5 T patient-sized MRI scanner. Simple-geometry phantom studies were performed to assess compatibility and performance characteristics regarding both optical and MR imaging systems. A bimodal ex vivo nude mouse measurement was conducted. From the MRI data, the subject surface was extracted. Optical images were projected on this surface by means of an inverse mapping algorithm. Simultaneous measurements did not reveal influences from the magnetic field and RF pulses onto optical detector performance (spatial resolution, sensitivity). No significant influence of the optical imaging system onto MRI performance was detectable. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:9
相关论文
共 21 条
  • [1] MRI-guided optical tomography: Prospects and computation for a new imaging method
    Barbour, RL
    Graber, HL
    Chang, JW
    Barbour, SLS
    Koo, PC
    Aronson, R
    [J]. IEEE COMPUTATIONAL SCIENCE & ENGINEERING, 1995, 2 (04): : 63 - 77
  • [2] Iterative reconstruction of projection images from a microlens-based optical detector
    Cao, Liji
    Peter, Joerg
    [J]. OPTICS EXPRESS, 2011, 19 (13): : 11932 - 11943
  • [3] QUADRATURE DETECTION COILS - A FURTHER SQUARE-ROOT2 IMPROVEMENT IN SENSITIVITY
    CHEN, CN
    HOULT, DI
    SANK, VJ
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1983, 54 (02) : 324 - 327
  • [4] Cherry SR, 2004, PHYS MED BIOL, V49, pR13, DOI 10.1088/0031-9155/49/3/R01
  • [5] A method for accurate calculation of B-1 fields in three dimensions. Effects of shield geometry on field strength and homogeneity in the birdcage coil
    Collins, CM
    Li, SZ
    Yang, QX
    Smith, MB
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1997, 125 (02) : 233 - 241
  • [6] Dynamic dual-tracer MRI-guided fluorescence tomography to quantify receptor density in vivo
    Davis, Scott C.
    Samkoe, Kimberley S.
    Tichauer, Kenneth M.
    Sexton, Kristian J.
    Gunn, Jason R.
    Deharvengt, Sophie J.
    Hasan, Tayyaba
    Pogue, Brian W.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (22) : 9025 - 9030
  • [7] Magnetic resonance-coupled fluorescence tomography scanner for molecular imaging of tissue
    Davis, Scott C.
    Pogue, Brian W.
    Springett, Roger
    Leussler, Christoph
    Mazurkewitz, Peter
    Tuttle, Stephen B.
    Gibbs-Strauss, Summer L.
    Jiang, Shudong S.
    Dehghani, Hamid
    Paulsen, Keith D.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (06)
  • [8] Combined diffuse optical tomography (DOT) and MRI system for cancer imaging in small animals
    Gulsen, Gultekin
    Birgul, Ozlem
    Unlu, Mehmet Burcin
    Shafiiha, Roshanak
    Nalcioglu, Orhan
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2006, 5 (04) : 351 - 363
  • [9] RF exposure of biological systems in radial waveguides
    Hansen, VW
    Bitz, AK
    Streckert, JR
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1999, 41 (04) : 487 - 493
  • [10] Simultaneous recording of task-induced changes in blood oxygenation, volume, and flow using diffuse optical imaging and arterial spin-labeling MRI
    Hoge, RD
    Franceschini, MA
    Covolan, RJM
    Huppert, T
    Mandeville, JB
    Boas, DA
    [J]. NEUROIMAGE, 2005, 25 (03) : 701 - 707