COLETTE: A linear Paul-trap beam cooler for the on-line mass spectrometer MISTRAL

被引:19
作者
Lunney, David [1 ]
Bachelet, Cyril [1 ]
Guenaut, Celine [1 ]
Henry, Sylvain [1 ]
Sewtz, Michael [1 ]
机构
[1] Univ Paris 11, CNRS, CSNSM IN2P3, F-91405 Orsay, France
关键词
Ion trapping; Ion cooling; Charged-particle beams; Mass spectrometers; ION-BEAMS; ACCUMULATION; IMPROVEMENT; PROGRAM;
D O I
10.1016/j.nima.2008.09.050
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A segmented, radiofrequency quadrupole mass filter COLETTE (Cooler for Emittance Elimination) was designed for cooling continuous radioactive beams for injection into the transmission spectrometer MISTRAL at CERN-ISOLDE. A description of the design of COLETTE is given, along with details of performance including measured emittances of less than 8 pi mm mrad with 20 keV beams from the test bench SIDONIE in Orsay. On-line results with stable and short-lived radionuclide beams from ISOLDE are also presented. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:379 / 387
页数:9
相关论文
共 39 条
[1]   Towards cooling of high-intensity ion beams [J].
Bachelet, C. ;
Block, M. ;
Bollen, G. ;
Moore, R. B. ;
Schwarz, S. .
HYPERFINE INTERACTIONS, 2006, 173 (1-3) :195-200
[2]   New binding energy for the two-neutron halo of 11Li [J].
Bachelet, C. ;
Audi, G. ;
Gaulard, C. ;
Guenaut, C. ;
Herfurth, F. ;
Lunney, D. ;
Simon, M. de Saint ;
Thibault, C. .
PHYSICAL REVIEW LETTERS, 2008, 100 (18)
[3]  
BACHELET C, 2004, THESIS U PARIS SUD O
[4]   SENSITIVITY OF ION TRAPS FOR SPECTROSCOPIC APPLICATIONS [J].
BLATT, R ;
SCHMELING, U ;
WERTH, G .
APPLIED PHYSICS, 1979, 20 (04) :295-298
[5]   The ion-trap facility SHIPTRAP -: Status and perspectives [J].
Block, M ;
Ackermann, D ;
Beck, D ;
Blaum, K ;
Breitenfeldt, M ;
Chauduri, A ;
Doemer, A ;
Eliseev, S ;
Habs, D ;
Heinz, S ;
Herfurth, F ;
Hessberger, FP ;
Hofmann, S ;
Geissel, H ;
Kluge, HJ ;
Kolhinen, V ;
Marx, G ;
Neumayr, JB ;
Mukherjee, M ;
Petrick, M ;
Plass, W ;
Quint, W ;
Rahaman, S ;
Rauth, C ;
Rodríguez, D ;
Scheidenberger, C ;
Schweikhard, L ;
Suhonen, M ;
Thirolf, PG ;
Wang, Z ;
Weber, C .
EUROPEAN PHYSICAL JOURNAL A, 2005, 25 (Suppl 1) :49-50
[6]   Experiments with thermalized rare isotope beams from projectile fragmentation:: A precision mass measurement of the superallowed β emitter 38Ca -: art. no. 152501 [J].
Bollen, G ;
Davies, D ;
Facina, M ;
Huikari, J ;
Kwan, E ;
Lofy, PA ;
Morrissey, DJ ;
Prinke, A ;
Ringle, R ;
Savory, J ;
Schury, P ;
Schwarz, S ;
Sumithrarachchi, C ;
Sun, T ;
Weissman, L .
PHYSICAL REVIEW LETTERS, 2006, 96 (15)
[7]   SIDONIE: an electromagnetic isotope separator for preparation of high purity thin targets [J].
Chauvin, N ;
Dayras, F ;
Le Du, D ;
Meunier, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 521 (01) :149-155
[8]   TRAPPING OF IONS FROM HIGH-ENERGY SOURCES INTO A RADIOFREQUENCY ION TRAP [J].
COUTANDIN, J ;
WERTH, G .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 29 (02) :89-92
[9]  
Dawson PH., 1976, QUADRUPOLE MASS SPEC, P95
[10]  
de Saint Simon M., 1995, Physica Scripta Volume T, VT59, P406