Evidence of interrelated side effects with reduced compliance in patients treated with nasal continuous positive airway pressure

被引:33
作者
Baltzan, Marcel A. [1 ,2 ]
Elkholi, Osama [1 ]
Wolkove, Norman [1 ]
机构
[1] Mt Sinai Hosp Ctr, Dept Med, Montreal, PQ H4W 1S7, Canada
[2] McGill Univ, Dept Epidemiol & Biostat, Royal Victoria Div Clin Epidemiol, Montreal, PQ, Canada
关键词
Sleep apnea syndromes; Sleep apnea; Polysomnography; Therapy; Positive pressure therapy; Clinical home care; OBSTRUCTIVE SLEEP-APNEA; LONG-TERM COMPLIANCE; CPAP THERAPY; MOUTH LEAK; POPULATION; ADHERENCE; HUMIDIFICATION; ASSOCIATION; MORTALITY; DISEASE;
D O I
10.1016/j.sleep.2007.12.005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: Patients treated for obstructive sleep apnea syndrome (OSAS) with nasal continuous positive airway pressure (nCPAP) often have side effects and poor compliance. Our objectives were to explore their side effects when treated with nCPAP and to validate the association of a side effect syndrome with the outcomes of sleep quality, daytime sleepiness and nCPAP compliance. Methods: Prospective exploratory and subsequent validation Study using questionnaires was performed in a tertiary-care sleep-disorders clinic. Consecutive patients with polysomnographic diagnosis and nCPAP titrations treated at least 3 months with single-pressure nCPAP were studied. In the first survey, 114 patients were questioned of whom 89 (78%) qualified for exploratory analysis. In the validation survey of 122 patients, 104 (85%) were studied. Subjects were interviewed and their nCPAP meters were queried. Results: In the first survey, 3 side effects were often found together and each found to be correlated to compliance: mouth leak with nCPAP, nasal congestion, and taking MY the mask prematurely. In the validation study, 34% of participants met a syndrome definition with Lit least 2 of 3 major side effects. Mean (SD) compliance was lower in patients with the syndrome: 4.97 (1.98) vs. 6.42 (1.56) hours per night (p = 0.0001). Pool sleep quality and lower satisfaction with nCPAP were associated with the syndrome. Conclusions: The syndrome of Mouth leak, taking off the nCPAP mask prematurely and nasal congestion is frequent ill patients treated with nCPAP. This is associated with lower compliance and pool sleep quality. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:198 / 205
页数:8
相关论文
共 45 条
  • [31] Prospective study of the association between sleep-disordered breathing and hypertension
    Peppard, PE
    Young, T
    Palta, M
    Skatrud, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (19) : 1378 - 1384
  • [32] Predictive factors for the need for additional humidification during nasal continuous positive airway pressure therapy
    Rakotonanahary, D
    Pelletier-Fleury, N
    Gagnadoux, F
    Fleury, B
    [J]. CHEST, 2001, 119 (02) : 460 - 465
  • [33] BREATHING DURING SLEEP IN PATIENTS TREATED FOR OBSTRUCTIVE SLEEP-APNEA - NASAL CPAP FOR ONLY PART OF THE NIGHT
    RAUSCHER, H
    POPP, W
    WANKE, T
    ZWICK, H
    [J]. CHEST, 1991, 100 (01) : 156 - 159
  • [34] Rechstchaffen A.e., 1968, A manual of standardized terminology, techniques, and scoring system for sleep stages of human subjects
  • [35] NASAL CPAP - AN OBJECTIVE EVALUATION OF PATIENT COMPLIANCE
    REEVESHOCHE, MK
    MECK, R
    ZWILLICH, CW
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (01) : 149 - 154
  • [36] Mouth leak with nasal continuous positive airway pressure increases nasal airway resistance
    Richards, GN
    Cistulli, PA
    Ungar, RG
    BerthonJones, M
    Sullivan, CE
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (01) : 182 - 186
  • [37] Shadan FF, 2005, J CLIN SLEEP MED, V1, P266
  • [38] Long-term compliance rates to continuous positive airway pressure in obstructive sleep apnea - A population-based study
    Sin, DD
    Mayers, I
    Man, GCW
    Pawluk, L
    [J]. CHEST, 2002, 121 (02) : 430 - 435
  • [39] Adhesive contact and kinetics of adherence between a rigid flat-ended cone and a soft elastomeric body
    Stephane, BA
    Barquins, M
    [J]. COMPTES RENDUS PHYSIQUE, 2002, 3 (02) : 239 - 245
  • [40] SULLIVAN CE, 1981, LANCET, V1, P862