An experimental comparison of two multi-louvered fin heat exchangers with different numbers of fin rows

被引:37
作者
Dogan, Bahadir [1 ]
Altun, Ozge [1 ]
Ugurlubilek, Nihal [1 ]
Tosun, Mert [2 ]
Saricay, Tugba [2 ]
Erbay, L. Berrin [1 ]
机构
[1] Eskisehir Osmangazi Univ, Sch Engn & Architecture, Dept Mech Engn, TR-26480 Bati Meselik, Eskisehir, Turkey
[2] Eskisehir Organized Ind Zone, Arcelik Refrigerator Plant, TR-26110 Eskisehir, Turkey
关键词
Heat transfer; Compact heat exchanger; Louvered fin; Flat tube; PRESSURE-DROP CORRELATIONS; FLUID-FLOW; PERFORMANCE; DESIGN;
D O I
10.1016/j.applthermaleng.2015.07.059
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental comparison of double-row and triple-row multi-louvered fin exchangers was performed to estimate air-side performance. The tests were conducted under identical thermal conditions. The studied heat exchangers had identical frontal areas and depths. Transient and steady state conditions were considered. The air-side thermal performance data were analyzed using the effectiveness-NTU method for a cross-flow heat exchanger with both fluids in unmixed conditions. The results were evaluated using the volume goodness factor j/f(1/3) for the air side, where j is the Colburn factor and f is the friction factor. As a result of the experimental study, the heat exchanger with double-row fins was found to be more effective in terms of NTU and effectiveness. The results of the present study were also compared with the correlations in the literature, and it was observed that the friction factor values of both models were in agreement with the values found in the literature. The maximum deviation of the friction factor was 15%, whereas the maximum deviation of the Colburn-j factor was 72% due to the geometrical discrepancies. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:270 / 278
页数:9
相关论文
共 28 条
[1]   Interaction effects between parameters in a vortex generator and louvered fin compact heat exchanger [J].
Ameel, Bernd ;
Degroote, Joris ;
Huisseune, Henk ;
Vierendeels, Jan ;
De Paepe, Michel .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 77 :247-256
[2]   AN EXPERIMENTAL-STUDY OF THE LOCAL HEAT-TRANSFER CHARACTERISTICS IN AUTOMOTIVE LOUVERED FINS [J].
AOKI, H ;
SHINAGAWA, T ;
SUGA, K .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1989, 2 (03) :293-300
[3]   Heat transfer analysis of fin-and-tube heat exchangers with flat and louvered fin geometries [J].
Carija, Zoran ;
Frankovic, Bernard ;
Percic, Marko ;
Cavrak, Marko .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 45 :160-167
[4]   Air side performance of brazed aluminum heat exchangers [J].
Chang, YJ ;
Wang, CC .
JOURNAL OF ENHANCED HEAT TRANSFER, 1996, 3 (01) :15-28
[5]   Thermal hydraulic performance of 10 PPI aluminium foam as alternative for louvered fins in an HVAC heat exchanger [J].
De Schampheleire, Sven ;
De Jaeger, Peter ;
Huisseune, Henk ;
Ameel, Bernd ;
T'Joen, Christophe ;
De Kerpel, Kathleen ;
De Paepe, Michel .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :371-382
[6]   Heat transfer and pressure drop correlations for the multi-louvered fin compact heat exchangers [J].
Dong, Junqi ;
Chen, Jiangping ;
Chen, Zhijiu ;
Zhang, Wenfeng ;
Zhou, Yimin .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (05) :1506-1515
[7]   Parametric study and optimization of louver finned-tube heat exchangers by Taguchi method [J].
Hsieh, Ching-Tsun ;
Jang, Jiin-Yuh .
APPLIED THERMAL ENGINEERING, 2012, 42 :101-110
[8]  
Incropera F. P., 1996, Fundamentals of heat and mass transfer
[9]  
Kakac S., 2002, HEAT EXCHANGERS SELE
[10]  
Kays W.M., 1984, COMPACT HEAT EXCHANG, V3rd