High-resolution ex vivo imaging of coronary artery stents using 64-slice computed tomography - initial experience

被引:26
作者
Rist, C [1 ]
Nikolaou, K
Flohr, T
Wintersperger, BJ
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Dept Clin Radiol, Munich, Germany
[2] Siemens Med Solut, CT Div, Forchheim, Germany
关键词
multislice CT; artefacts; stents; coronary artery;
D O I
10.1007/s00330-006-0186-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265 +/- 25HU and 254 +/- 16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367 +/- 36HU versus 402 +/- 28HU, P < 0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68 +/- 0.08 mm versus 2.81 +/- 0.07 mm and 3.29 +/- 0.06 mm versus 3.18 +/- 0.07 mm (P < 0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.
引用
收藏
页码:1564 / 1569
页数:6
相关论文
共 14 条
  • [1] *AM HEART ASS, 2004, HEART STROK STAT UPD
  • [2] Restenosis after coronary stenting in current clinical practice
    Antoniucci, D
    Valenti, R
    Santoro, GM
    Bolognese, L
    Trapani, M
    Cerisano, G
    Boddi, V
    Fazzini, PF
    [J]. AMERICAN HEART JOURNAL, 1998, 135 (03) : 510 - 518
  • [3] Performance evaluation of a 64-slice CT system with z-flying focal spot
    Flohr, T
    Stierstorfer, K
    Raupach, R
    Ulzheimer, S
    Bruder, H
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (12): : 1803 - 1810
  • [4] Noninvasive assessment of left main coronary stent patency with 16-slice computed tomography
    Gilard, M
    Cornily, JC
    Rioufol, G
    Finet, G
    Pennec, PY
    Mansourati, J
    Blanc, JJ
    Boschat, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (01) : 110 - 112
  • [5] Ligabue Guido, 2004, Radiol Med, V108, P128
  • [6] Mahnken AH, 2005, INVEST RADIOL, V40, P8
  • [7] Coronary artery stents in multislice computed tomography -: In vitro artifact evaluation
    Mahnken, AH
    Buecker, A
    Wildberger, JE
    Ruebben, A
    Stanzel, S
    Vogt, F
    Günther, RW
    Blindt, R
    [J]. INVESTIGATIVE RADIOLOGY, 2004, 39 (01) : 27 - 33
  • [8] Maintz D, 2003, INVEST RADIOL, V38, P790, DOI 10.1097/01.rli.0000086495.96457.54
  • [9] Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation
    Maintz, D
    Juergens, KU
    Wichter, T
    Grude, M
    Heindel, W
    Fischbach, R
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (04) : 830 - 835
  • [10] Assessment of coronary arterial stents by multislice-CT angiography
    Maintz, D
    Grude, M
    Fallenberg, EM
    Heindel, W
    Fischbach, R
    [J]. ACTA RADIOLOGICA, 2003, 44 (06) : 597 - 603