Evaluation of stability and capsular bag opacification of a new foldable adjustable intraocular lens

被引:18
作者
MacLean, Kyle D. [1 ]
Werner, Liliana [1 ]
Kramer, Gregory D. [1 ]
Farukhi, M. Aabid [1 ]
Gardiner, Gareth L. [1 ]
Kahook, Malik Y. [2 ]
Mamalis, Nick [1 ]
机构
[1] Univ Utah, John A Moran Eye Ctr, Dept Ophthalmol & Visual Sci, Salt Lake City, UT 84132 USA
[2] Univ Colorado, Sch Med, Dept Ophthalmol, Aurora, CO USA
关键词
cataract surgery; intraocular lens; posterior capsule opacification; ZEALAND ALBINO RABBITS; CATARACT-SURGERY; FOLLOW-UP; REGENERATION; IMPLANTATION; PREVENTION; EXTRACTION; OUTCOMES;
D O I
10.1111/ceo.12526
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundIncorrect lens power remains one of the most common reasons for intraocular lens explantation/exchange. We evaluated stability and effect on capsular bag opacification of a new foldable modular lens system, with a base component and an optic component in rabbit eyes. MethodsBilateral phacoemulsification was performed on six rabbits; one eye received the test lens (Harmoni Modular Lens, ClarVista Medical), whereas the other received a single-piece hydrophobic acrylic control lens (SA60AT, Alcon). Slit-lamp examinations were performed at postoperative weeks 1, 2, 3, 4 and 6. All rabbits were sacrificed at week 6. After enucleation, the eyes were examined grossly from the Miyake-Apple view. Following, all globes were sectioned and processed for histopathological examination. ResultsThe modular lens was stable in all six rabbits. Uveal biocompatibility was similar to or better in the test eyes when compared with control eyes up to 6 weeks postoperatively. Overall, capsular bag opacification was found to be significantly lower in the test eyes when compared with control eyes. At the 6-week gross examination, central posterior capsule opacification was scored as 0.580.73 in the test group, and as 3.00 +/- 1.26 in the control group (paired two samples for means t-test; two-tail P=0.005). ConclusionsThe Harmoni Modular system remains stable within the capsular bag after implantation. Due to the design of the base component featuring long loops, along with peripheral anterior and posterior square edges, the lens appeared to prevent overall capsular bag opacification in the rabbit model.
引用
收藏
页码:648 / 654
页数:7
相关论文
共 50 条
  • [41] Zwitterionic modified and freeze-thaw reinforced foldable hydrogel as intraocular lens for posterior capsule opacification prevention
    Yang, Cheng-Jui
    Huang, Wei-Lun
    Yang, Yu
    Kuan, Chen-Hsiang
    Tseng, Ching-Li
    Wang, Tzu-Wei
    BIOMATERIALS, 2024, 309
  • [42] Anti-Adhesive And Antiproliferative Synergistic Surface Modification Of Intraocular Lens For Reduced Posterior Capsular Opacification
    Han, Yuemei
    Tang, Junmei
    Xia, Jiayi
    Wang, Rui
    Qin, Chen
    Liu, Sihao
    Zhao, Xia
    Chen, Hao
    Lin, Quankui
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2019, 14 : 9047 - 9061
  • [43] Long-term myofibroblast persistence in the capsular bag contributes to the late spontaneous in-the-bag intraocular lens dislocation
    Bisevac, Jovana
    Anisimova, Natalia S.
    Nagymihaly, Richard
    Kristianslund, Olav
    Katta, Kirankumar
    Noer, Agate
    Sharafetdinov, Ilias H.
    Drolsum, Liv
    Moe, Morten C.
    Malyugin, Boris E.
    Petrovski, Goran
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [44] Long-term uveal and capsular biocompatibility of a new accommodating intraocular lens
    Kohl, Justin C.
    Werner, Liliana
    Ford, Joshua R.
    Cole, Scott C.
    Vasavada, Shall A.
    Gardiner, Gareth L.
    Noristani, Rozina
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12) : 2113 - 2119
  • [45] Antiproliferative drug-loaded multi-functionalized intraocular lens for reducing posterior capsular opacification
    Huang, Huiying
    Zhu, Siqing
    Liu, Dong
    Wen, Shimin
    Lin, Quankui
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2021, 32 (06) : 735 - 748
  • [46] Cascade reaction triggering and photothermal AuNPs@MIL MOFs doped intraocular lens for enhanced posterior capsular opacification prevention
    Hong, Yueze
    Fang, Qiuna
    Bai, Ting
    Zhao, Peiyi
    Han, Yuemei
    Lin, Quankui
    JOURNAL OF NANOBIOTECHNOLOGY, 2023, 21 (01)
  • [47] The Effect of Scleral Sutured Intraocular Lens with Optic-haptic Junction Fixation in the Capsular Bag
    Lee, Sun Young
    Cho, Yang Kyung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2021, 62 (09): : 1172 - 1180
  • [48] Preclinical biocompatibility and biosafety evaluation of a new foldable brown diaphragm intraocular lens: An in vitro and in vivo study
    Zhang, Keke
    Zhang, Shaohua
    He, Wenwen
    Lu, Yi
    Zhu, Xiangjia
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (04) : 359 - 369
  • [49] Bilateral spontaneous anterior dislocation of intraocular lens with the capsular bag in a patient with pseudoexfoliation
    Bhattacharjee, Harsha
    Saxena, Rushil Kumar
    Medhi, Jnanankar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (10) : 796 - U74
  • [50] Comparison of additional pseudophakic multifocal lenses and multifocal intraocular lens in the capsular bag
    Schrecker, J.
    Feith, A.
    Langenbucher, A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 (07) : 915 - 919