Design of an Out-Folded Patch Antenna With a Zeroth-Order Resonance for Non-Invasive Continuous Glucose Monitoring

被引:9
|
作者
Nguyen, Mai Anh [1 ]
Bien, Franklin [1 ]
Byun, Gangil [1 ]
机构
[1] Ulsan Natl Inst Sci & Technol UNIST, Ulsan 44919, South Korea
关键词
Glucose; Transmission line measurements; Geometry; Antennas; Skin; Resonant frequency; Antenna measurements; Composite right-; left-handed (CRLH) transmission line (TL); continuous glucose monitoring (CGM); folded patch antenna; noninvasive sensing; zeroth-order resonance (ZOR); BLOOD-GLUCOSE; SENSOR;
D O I
10.1109/TAP.2022.3177517
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes an out-folded patch antenna with a zeroth-order resonance (ZOR) that is robust to a high-dielectric condition of a human body for noninvasive continuous glucose monitoring (CGM). The proposed antenna has two faces of a tapered section and a rectangular patch separated by a gap, and those faces are connected through vias at two corners near the gap. Two identical antennas are fabricated on a flexible printed circuit board (FPCB), and the properties of ZOR are compared with those of the fundamental mode to demonstrate the feasibility. The ZOR of the proposed antenna exhibits a negligible frequency shift, and its quality factor is 2.9 times higher than the fundamental mode, when attached to the skin. The evaluation is further extended to a human experiment using the two antennas for real-time estimation of coupling strength according to the change in glucose concentration. The trend of measured coupling strength well describes that of the glucose concentration obtained from a glucose meter with a mean absolute relative difference of 12.23%. The results demonstrate that the proposed concept has a great potential to improve the accuracy of noninvasive estimation in microwave spectrum.
引用
收藏
页码:8932 / 8940
页数:9
相关论文
共 50 条
  • [41] Evaluation of a non-invasive continuous glucose monitoring device in a home use setting
    Amir, O.
    Kononenko, A.
    Gabis, E.
    Karasik, A.
    DIABETOLOGIA, 2006, 49 : 581 - 581
  • [42] Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
    Heinemann, L
    Schmelzeisen-Redeker, G
    DIABETOLOGIA, 1998, 41 (07) : 848 - 854
  • [43] Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
    L. Heinemann
    G. Schmelzeisen-Redeker
    Diabetologia, 1998, 41 : 848 - 854
  • [44] A glucose sensing contact lens: A new approach to non-invasive continuous physiological glucose monitoring
    Badugu, R
    Lakowicz, JR
    Geddes, CD
    OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS IV, 2004, 5317 : 234 - 245
  • [45] Technologies for non-invasive and continuous blood glucose monitoring in sports: a Patent Landscape Analysis
    Massone, Pietro
    Barbieri, Massimo
    Angelucci, Alessandra
    Aliverti, Andrea
    2024 IEEE INTERNATIONAL WORKSHOP ON SPORT, TECHNOLOGY AND RESEARCH, STAR 2024, 2024, : 5 - 10
  • [46] Highly accurate non-invasive continuous glucose monitoring in clinical and home use settings
    Amir, Orna
    Kononenko, Alex
    Cohen, Ohad
    Dvir, David
    Gabis, Efi
    Monashkin, Emanuel
    Karasik, Avraham
    DIABETES, 2006, 55 : A90 - A90
  • [47] Non-invasive continuous glucose monitoring during oral glucose tolerance tests in volunteers and diabetic patients
    Heinemann, L
    Krämer, U
    Klötzer, HM
    Hermann, M
    DIABETOLOGIA, 1999, 42 : A64 - A64
  • [48] EFFECTS OF SWEAT EVENTS ON THE CALIBRATION OF A MULTISENSOR DEVICE FOR NON-INVASIVE CONTINUOUS GLUCOSE MONITORING
    Zanon, M.
    Sparacino, G.
    Facchinetti, A.
    Talary, M. S.
    Caduff, A.
    Cobelli, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A77 - A77
  • [49] Non-invasive continuous glucose monitoring during physiological blood glucose changes in volunteers and diabetic patients
    Heinemann, L
    Kraemer, U
    Kloetzer, HM
    Hermann, M
    DIABETES, 1999, 48 : A359 - A359
  • [50] Evaluation of a non-invasive, continuous glucose monitoring system in patients with diabetes: Results of a glucose clamp study
    Caduff, A
    Kapitza, C
    Dewarrat, R
    Buschor, S
    Schrepfer, T
    Heinemann, L
    DIABETES, 2003, 52 : A91 - A91