Design of an Out-Folded Patch Antenna With a Zeroth-Order Resonance for Non-Invasive Continuous Glucose Monitoring

被引:9
|
作者
Nguyen, Mai Anh [1 ]
Bien, Franklin [1 ]
Byun, Gangil [1 ]
机构
[1] Ulsan Natl Inst Sci & Technol UNIST, Ulsan 44919, South Korea
关键词
Glucose; Transmission line measurements; Geometry; Antennas; Skin; Resonant frequency; Antenna measurements; Composite right-; left-handed (CRLH) transmission line (TL); continuous glucose monitoring (CGM); folded patch antenna; noninvasive sensing; zeroth-order resonance (ZOR); BLOOD-GLUCOSE; SENSOR;
D O I
10.1109/TAP.2022.3177517
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article proposes an out-folded patch antenna with a zeroth-order resonance (ZOR) that is robust to a high-dielectric condition of a human body for noninvasive continuous glucose monitoring (CGM). The proposed antenna has two faces of a tapered section and a rectangular patch separated by a gap, and those faces are connected through vias at two corners near the gap. Two identical antennas are fabricated on a flexible printed circuit board (FPCB), and the properties of ZOR are compared with those of the fundamental mode to demonstrate the feasibility. The ZOR of the proposed antenna exhibits a negligible frequency shift, and its quality factor is 2.9 times higher than the fundamental mode, when attached to the skin. The evaluation is further extended to a human experiment using the two antennas for real-time estimation of coupling strength according to the change in glucose concentration. The trend of measured coupling strength well describes that of the glucose concentration obtained from a glucose meter with a mean absolute relative difference of 12.23%. The results demonstrate that the proposed concept has a great potential to improve the accuracy of noninvasive estimation in microwave spectrum.
引用
收藏
页码:8932 / 8940
页数:9
相关论文
共 50 条
  • [31] Synthesis and Biocompatibility Study of Hydrogel for Patch Sensor in Non-invasive Glucose Monitoring System
    Kwon, Jeong Woo
    Kim, Dong Chul
    Yoon, In Joon
    Jeong, Yoon Na
    Jeong, Ji Young
    Hwang, In Sik
    POLYMER-KOREA, 2009, 33 (02) : 111 - 117
  • [32] Design of microstrip patch sensor for non-invasive body electrolyte monitoring.
    Rakib, Sakhawat Hossen
    Reza, Md Taslim
    Islam, Md Fokhrul
    2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1110 - 1113
  • [33] A Stacked Patch MIMO Antenna With Circular Polarization for non-invasive Blood Glucose Sensing Application
    Raj, Saurabh
    Upadhyay, Gaurav
    Kishore, Nand
    Tripathi, Shivesh
    Tripathi, Vijay Shanker
    2018 5TH IEEE UTTAR PRADESH SECTION INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS AND COMPUTER ENGINEERING (UPCON), 2018, : 794 - 797
  • [34] Continuous Non-invasive blood glucose monitoring by spectral image differencing method
    Huang, Hao
    Liao, Ningfang
    Cheng, Haobo
    Liang, Jing
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY - OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2017, 10621
  • [35] A Low Cost Design Non-invasive Glucose Monitoring Experimental Setup
    Evren, Elif
    Kocak, Onur
    2018 MEDICAL TECHNOLOGIES NATIONAL CONGRESS (TIPTEKNO), 2018,
  • [36] Multi-sensor data fusion for non-invasive continuous glucose monitoring
    Huber, Daniel
    Staedler, Nicolas
    Falco-Jonasson, Lisa
    Dewarrat, Francois
    Talary, Mark
    Caduff, Andreas
    Stahel, Werner
    2007 PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION FUSION, VOLS 1-4, 2007, : 963 - +
  • [37] THE FEASIBILITY OF NON-INVASIVE CONTINUOUS GLUCOSE MONITORING WITH THE NOVEL LIFELEAF WRISTWATCH AND PLATFORM
    Bailey, T.
    Fischer, J.
    Kohn, M.
    Sen-Gupta, I.
    Broz, J.
    Sanyal, A.
    Mbouombouo, B.
    Banerjee, N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A250 - A250
  • [38] Comparison of the Simultaneous Use of Two Multisensors for Non-Invasive Continuous Glucose Monitoring
    Caduff, Andreas
    Mueller, Martin
    Zakharov, Pavel
    Megej, Alex
    Donath, Marc
    Klisic, Jelena
    Stahel, Werner A.
    Talary, Mark S.
    DIABETES, 2011, 60 : A242 - A242
  • [39] Hydrogel-based electrochemical sensor for non-invasive and continuous glucose monitoring
    Park, Habeen
    Lee, Ji-Young
    Kim, Dong-Chul
    Koh, Younggook
    Cha, Junhoe
    INTERNATIONAL CONFERENCE ON NANO-BIO SENSING, IMAGING, AND SPECTROSCOPY 2017, 2017, 10324
  • [40] Non-invasive continuous glucose monitoring - Results from the first 62 subjects
    Weiss, Ram
    Yegorchikov, Yevgeny
    Shusterman, Alexander
    Raz, Itamar
    DIABETES, 2006, 55 : A96 - A96