共 50 条
Frequency-doubling technology and retinal measurements with spectral-domain optical coherence tomography in preperimetric glaucoma
被引:34
|作者:
Hirashima, Takafumi
[1
]
Hangai, Masanori
[1
]
Nukada, Masayuki
[1
]
Nakano, Noriko
[1
]
Morooka, Satoshi
[1
]
Akagi, Tadamichi
[1
]
Nonaka, Atsushi
[1
]
Yoshimura, Nagahisa
[1
]
机构:
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
基金:
日本学术振兴会;
关键词:
Preperimetric glaucoma;
Frequency-doubling technology perimetry;
Standard automated perimetry;
Heidelberg retinal tomography-2;
Receiver-operating characteristic curves;
WAVELENGTH AUTOMATED PERIMETRY;
VISUAL-FIELD DEFECTS;
STRATUS OCT;
THICKNESS;
PREDICTION;
MATRIX;
DAMAGE;
ONSET;
D O I:
10.1007/s00417-012-2076-7
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
To determine the relationship between visual fields and retinal structures measured with spectral-domain optical coherence tomography in preperimetric glaucoma (PPG). Twenty-six eyes of 26 patients with PPG and 20 healthy eyes of 20 volunteers were included. All patients underwent Heidelberg retina tomography-2 (HRT2), standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and RTVue-100. SAP and FDT indices, HRT parameters, and circumpapillary retinal nerve fiber layer (cpRNFL) and macular ganglion cell complex (mGCC) thicknesses were correlated using Pearson's test. Areas under the receiver operating characteristic curves (AUROCs) and sensitivity/specificity based on each parameter's definition of abnormalities were compared between parameters. Significant differences were found in FDT-MD, FDT-PSD, SAP-PSD, cpRNFL, and mGCC parameters (p < 0.001-0.015), but not in SAP-MD or HRT parameters, between PPG and control groups. Significant correlations were not found between visual field indices and structural parameters, except between FDT-MD and HRT rim area (r = 0.450, p = 0.021) and between FDT-PSD and temporal cpRNFL thickness (r = 0.402, p = 0.021). AUROCs for cpRNFL (p = 0.0047-0.033) and mGCC (p = 0.0082-0.049) parameters were significantly better than those of HRT parameters, whereas significant differences were not found between FDT indices and cpRNFL or mGCC parameters or between cpRNFL and mGCC parameters. Adding average cpRNFL or mGCC thickness to FDT-MD significantly increased sensitivity compared to single parameters (p = 0.016-0.031). Structural and functional parameters were poorly correlated but complementary for glaucoma detection in PPG. Combining these parameters may improve PPG diagnosis.
引用
收藏
页码:129 / 137
页数:9
相关论文