Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss

被引:106
作者
Abolghasemian, M. [1 ]
Tangsataporn, S. [1 ]
Sternheim, A. [1 ]
Backstein, D. [1 ]
Safir, O. [1 ]
Gross, A. E. [1 ]
机构
[1] Univ Toronto, Mt Sinai Hosp, Toronto, ON M5G 1X5, Canada
关键词
TOTAL HIP-ARTHROPLASTY; FOLLOW-UP; PELVIC DISCONTINUITY; POROUS TANTALUM; JUMBO CUPS; COMPONENT; CLASSIFICATION; DEFECTS; RECONSTRUCTION; REPLACEMENT;
D O I
10.1302/0301-620X.95B2.30608
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Trabecular metal (TM) augments are a relatively new option for reconstructing segmental bone loss during acetabular revision. We studied 34 failed hip replacements in 34 patients that were revised between October 2003 and March 2010 using a TM acetabular shell and one or two augments. The mean age of the patients at the time of surgery was 69.3 years (46 to 86) and the mean follow-up was 64.5 months (27 to 107). In all, 18 patients had a minor column defect, 14 had a major column defect, and two were associated with pelvic discontinuity. The hip centre of rotation was restored in 27 patients (79.4%). The Oxford hip score increased from a mean of 15.4 points (6 to 25) before revision to a mean of 37.7 (29 to 47) at the final follow-up. There were three aseptic loosenings of the construct, two of them in the patients with pelvic discontinuity. One septic loosening also occurred in a patient who had previously had an infected hip replacement. The augments remained stable in two of the failed hips. Whenever there was a loose acetabular component in contact with a stable augment, progressive metal debris shedding was evident on the serial radiographs. Complications included another deep infection treated without revision surgery. Good clinical and radiological results can be expected for bone-deficient acetabula treated by a TM cup and augment, but for pelvic discontinuities this might not be a reliable option.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 32 条
[1]   Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial [J].
Bobyn, JD ;
Stackpool, GJ ;
Hacking, SA ;
Tanzer, M ;
Krygier, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (05) :907-914
[2]  
BOBYN JD, 1980, CLIN ORTHOP RELAT R, P291
[3]  
Bozic KJ, 2004, CLIN ORTHOP RELAT R, P101
[4]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[5]   Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency [J].
Chen, WM ;
Engh, CA ;
Hopper, RH ;
McAuley, JP ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (02) :197-206
[6]   Revision of the acetabular component without cement after total hip arthroplasty - A concise follow-up, at fifteen to nineteen years, of a previous report [J].
Della Valle, CJ ;
Shuaipaj, T ;
Berger, RA ;
Rosenberg, AG ;
Shott, S ;
Jacobs, JJ ;
Galante, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (08) :1795-1800
[7]  
Delp SL, 1996, CLIN ORTHOP RELAT R, P137
[8]   Management of severe bone loss in acetabular revision using a trabecular metal shell [J].
Flecher, Xavier ;
Sporer, Scott ;
Paprosky, Wayne .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :949-955
[9]   Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft - Study with a minimum five-year follow-up [J].
Garbuz, D ;
Morsi, E ;
Gross, AE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (05) :693-697
[10]   Porous-coated cementless acetabular cups in revision surgery - A 6-to 11-year follow-up study [J].
Garcia-Cimbrelo, E .
JOURNAL OF ARTHROPLASTY, 1999, 14 (04) :397-406