First versus subsequent return-stroke current and field peaks in negative cloud-to-ground lightning discharges

被引:30
作者
Nag, Amitabh [1 ]
Rakov, Vladimir A. [1 ]
Schulz, Wolfgang [4 ]
Saba, Marcelo M. F. [3 ]
Thottappillil, Rajeev [2 ]
Biagi, Christopher J. [1 ]
Oliveira Filho, Alcides [3 ]
Kafri, Ahmad [2 ]
Theethayi, Nelson [2 ]
Gotschl, Thomas [2 ]
机构
[1] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
[2] Uppsala Univ, Div Elect & Lightning Res, Angstrom Lab, S-75121 Uppsala, Sweden
[3] Natl Inst Space Res, BR-12201970 Sao Jose Dos Campos, SP, Brazil
[4] Austrian Elect Assoc, OVE ALDIS, A-1190 Vienna, Austria
关键词
D O I
10.1029/2007JD009729
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
We examine relative magnitudes of electric field peaks of first and subsequent return strokes in negative cloud-to-ground lightning flashes recorded in Florida, Austria, Brazil, and Sweden. On average, the electric field peak of the first stroke is appreciably, 1.7 to 2.4 times, larger than the field peak of the subsequent stroke ( except for studies in Austria where the ratio varies from 1.0 to 2.3, depending on methodology and instrumentation). Similar results were previously reported from electric field studies in Florida, Sweden, and Sri Lanka. For comparison, directly measured peak currents for first strokes are, on average, a factor of 2.3 to 2.5 larger than those for subsequent strokes. There are some discrepancies between first versus subsequent stroke intensities reported from different studies based on data reported by lightning locating systems (LLS). The ratio of LLS-reported peak currents for first and subsequent strokes confirmed by video records is 1.7 to 2.1 in Brazil, while in the United States ( Arizona, Texas, Oklahoma, and the Great Plains) it varies from 1.1 to 1.6, depending on methodology used. The smaller ratios derived from the LLS studies are likely to be due to poor detection of relatively small subsequent strokes. The smaller values in Austria are possibly related ( at least in part) to the higher percentage ( about 50% versus 24-38% in other studies) of flashes with at least one subsequent stroke greater than the first. The effects of excluding single-stroke flashes or subsequent strokes in newly formed channels appear to be relatively small.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Influence of Channel Length, Return-Stroke Speed and Ground Conductivity on Horizontal Electric Field Associated with Nearby Lightning Return Strokes
    Yu, J. L.
    Fan, Y. D.
    Wang, J. G.
    Zhou, M.
    Cai, L.
    Huang, S. B.
    Hu, C.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 197 - 201
  • [42] Characteristics of a bipolar cloud-to-ground lightning flash containing a positive stroke followed by three negative strokes
    Tian, Ye
    Qie, Xiushu
    Lu, Gaopeng
    Jiang, Rubin
    Wang, Zhichao
    Zhang, Hongbo
    Liu, Mingyuan
    Sun, Zhuling
    Feng, Guili
    ATMOSPHERIC RESEARCH, 2016, 176 : 222 - 230
  • [43] A Simplified approach to understanding of the phenomenon of cloud to ground lightning and modeling of return stroke current
    Gayen, Arun
    Dhar, Anirban
    Das, B. N.
    Poddar, D. R.
    INCEMIC 2006: 9TH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY, PROCEEDINGS, 2006, : 358 - 362
  • [44] Statistical analysis of negative cloud-to-ground lightning characteristics in Bogota, Colombia based on electric field measurements
    Enrique Rojas, Herbert
    David Rojas, Havey
    Andres Cortes, Camilo
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2022, 227
  • [45] Post-return stroke VHF electromagnetic activity in north-western Mediterranean cloud-to-ground lightning flashes
    Kolinska, Andrea
    Kolmasova, Ivana
    Defer, Eric
    Santolik, Ondrej
    Pedeboy, Stephane
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2025, 25 (03) : 1791 - 1803
  • [46] Electric field changes generated by the preliminary breakdown for the negative cloud-to-ground lightning flashes in Malaysia and Sweden
    Baharudin, Z. A.
    Fernando, M.
    Ahmad, Noor Azlinda
    Makela, J. S.
    Rahman, Mahbubur
    Cooray, Vernon
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2012, 84-85 : 15 - 24
  • [47] A Decade of Cloud-to-Ground Lightning in Canada: 1999-2008. Part 2: Polarity, Multiplicity and First-Stroke Peak Current
    Kochtubajda, Bohdan
    Burrows, William R.
    ATMOSPHERE-OCEAN, 2010, 48 (03) : 195 - 209
  • [48] A study of the time interval between return strokes and K-changes of negative cloud-to-ground lightning flashes in Brazil
    de Miranda, FJ
    Pinto, O
    Saba, MMF
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2003, 65 (03) : 293 - 297
  • [49] Characteristics of upward-connecting-leader current leading to attachment in downward negative cloud-to-ground lightning strokes
    Nag, Amitabh
    Cummins, Kenneth L.
    Plaisir, Mathieu N.
    Brown, Robert G.
    Wilson, Jennifer G.
    Crawford, David E.
    Noggle, R. Carl
    Rassoul, Hamid K.
    ATMOSPHERIC RESEARCH, 2023, 294
  • [50] Properties of the unusually short pulse sequences occurring prior to the first strokes of negative cloud-to-ground lightning flashes
    Kolmasova, Ivana
    Santolik, Ondrej
    Farges, Thomas
    Rison, William
    Lan, Radek
    Uhlir, Ludek
    GEOPHYSICAL RESEARCH LETTERS, 2014, 41 (14) : 5316 - 5324