Single Cell Real-Time miRNAs Sensing Based on Nanomotors

被引:269
作者
de Avila, Berta Esteban-Fernandez [1 ]
Martin, Aida [1 ,2 ]
Soto, Fernando [1 ]
Lopez-Ramirez, Miguel Angel [1 ]
Campuzano, Susana [3 ]
Vasquez-Machado, Gersson Manuel
Gao, Weiwei [1 ]
Zhang, Liangfang [1 ]
Wang, Joseph [1 ]
机构
[1] Univ Calif San Diego, Dept Nanoengn, La Jolla, CA 92093 USA
[2] Univ Alcala de Henares, Dept Analyt Chem, E-28871 Madrid, Spain
[3] Univ Complutense Madrid, Dept Analyt Chem, E-28040 Madrid, Spain
关键词
miRNAs; real-time biosensing; single intact cancer cells; nanomotors; graphene oxide; ultrasound; RESONANCE ENERGY-TRANSFER; NANO-GRAPHENE OXIDE; MICRORNA DETECTION; NUCLEIC-ACID; MICROMOTORS; EXPRESSION; BIOSENSORS; TARGETS; PROBES; MOTION;
D O I
10.1021/acsnano.5b02807
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A nanomotor-based strategy for rapid single-step intracellular biosensing of a target miRNA, expressed in intact cancer cells, at the single cell level is described. The new concept relies on the use of ultrasound (US) propelled dye-labeled single-stranded DNA (ssDNA)/graphene-oxide (GO) coated gold nanowires (AuNWs) capable of penetrating intact cancer cells. Once the nanomotor is internalized into the cell, the quenched fluorescence signal (produced by the pi-pi interaction between GO and a dye-labeled ssDNA) is recovered due to the displacement of the dye-ssDNA probe from the motor GO-quenching surface upon binding with the target miRNA-21, leading to an attractive intracellular "OFF-ON" fluorescence switching. The faster internalization process of the US-powered nanomotors and their rapid movement into the cells increase the likelihood of probe target contacts, leading to a highly efficient and rapid hybridization. The ability of the nanomotor-based method to screen cancer cells based on the endogenous content of the target miRNA has been demonstrated by measuring the fluorescence signal in two types of cancer cells (MCF-7 and HeLa) with significantly different miRNA-21 expression levels. This single-step, motor-based miRNAs sensing approach enables rapid "on the move" specific detection of the target miRNA-21, even in single cells with an extremely low endogenous miRNA-21 content, allowing precise and real-time monitoring of intracellular miRNA expression.
引用
收藏
页码:6756 / 6764
页数:9
相关论文
共 50 条
  • [41] In Situ Single-Cell Stimulation and Real-Time Electrochemical Detection of Lactate Response Using a Microfluidic Probe
    Zhou, Lin
    Kasai, Nahoko
    Nakajima, Hizuru
    Kato, Shungo
    Mao, Sifeng
    Uchiyama, Katsumi
    ANALYTICAL CHEMISTRY, 2021, 93 (24) : 8680 - 8686
  • [42] Dual DNAzyme amplification-based colorimetric sensing assay for the identification and quantification of tumor-associated miRNAs
    Wang, Ruili
    Peng, Ruiying
    Song, Liran
    Li, Jishan
    TALANTA, 2025, 286
  • [43] Real-time qRT-PCR assay for the detection of miRNAs using bi-directional extension sequences
    Kim, Kyung Jin
    Kwak, Jiwon
    Lee, Jae-Hoon
    Lee, Soo Suk
    ANALYTICAL BIOCHEMISTRY, 2017, 536 : 32 - 35
  • [44] A capillary dielectrophoretic chip for real-time blood cell separation from a drop of whole blood
    Liao, Shu-Hsien
    Chang, Ching-Yu
    Chang, Hsien-Chang
    BIOMICROFLUIDICS, 2013, 7 (02):
  • [45] Real-time sensing and low-cost experimental setup for water quantity investigation in Nature-based Solutions
    Gobatti, Lucas
    Scarati Martins, Jose Rodolfo
    Santana Pereira, Maria Cristina
    Coelho Leite, Brenda Chaves
    BLUE-GREEN SYSTEMS, 2022, 4 (02) : 75 - 88
  • [46] Real-time tracking of a moving contacting load using the distributive tactile sensing method
    Brett, P. N.
    Ma, X.
    Holding, D. J.
    Elliott, M. T.
    Petra, I.
    14TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE 2007, PROCEEDINGS, 2007, : 136 - 139
  • [47] A fixed cytometer chip for identification of cell populations and real-time monitoring of single-cell apoptosis under gradient UV radiation
    Xia, Anyue
    Gan, Mingzhe
    Xu, Huan
    Zhang, Yiheng
    Wang, Dandan
    Du, Jing
    Sun, Qian
    Jiang, Jiana
    Luo, Dan
    Cui, Jinhui
    Liu, Peifeng
    MICROFLUIDICS AND NANOFLUIDICS, 2019, 23 (06)
  • [48] Real-time Bio(Chemical)sensing with Etched Clad Fiber Bragg Grating Sensors
    Prashanth, Gurusiddappa R.
    Nanjunda, Shivananju B.
    Asokan, Sunderrajan
    Varma, Manoj M.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XII, 2012, 8218
  • [49] State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics
    Ghaffari, Roozbeh
    Yang, Da Som
    Kim, Joohee
    Mansour, Amer
    Wright, John A. Jr Jr
    Model, Jeffrey B.
    Wright, Donald E.
    Rogers, John A.
    Ray, Tyler R.
    ACS SENSORS, 2021, 6 (08) : 2787 - 2801
  • [50] Biodegradable Implant Antenna Utilized for Real-Time Sensing through Genetically Modified Bacteria
    Bilir, Ahmet
    Dumanli, Sema
    2024 18TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2024,