Artifact reduction in magnetogastrography using fast independent component analysis

被引:26
作者
Irimia, A [1 ]
Bradshaw, LA [1 ]
机构
[1] Vanderbilt Univ, Dept Phys & Astron, Living State Phys Grp, Nashville, TN 37235 USA
关键词
artifact reduction; magnetogastrography; independent component analysis;
D O I
10.1088/0967-3334/26/6/015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The analysis of magnetogastrographic (MGG) signals has been limited to epochs of data with limited interference from extraneous signal components that are often present and may even dominate MGG data. Such artifacts can be of both biological (cardiac, intestinal and muscular activities, motion artifacts, etc) and non-biological (environmental noise) origin. Conventional methods-such as Butterworth and Tchebyshev filters-can be of great use, but there are many disadvantages associated with them as well as with other typical filtering methods because a large amount of useful biological information can be lost, and there are many trade-offs between various filtering methods. Moreover, conventional filtering cannot always fully address the physicality of the signal-processing problem in terms of extracting specific signals due to particular biological sources of interest such as the stomach, heart and bowel. In this paper, we demonstrate the use of fast independent component analysis (FICA) for the removal of both biological and non-biological artifacts from multi-channel MGG recordings acquired using a superconducting quantum intereference device (SQUID) magnetometer. Specifically, we show that the signal of gastric electrical control activity (ECA) can be isolated from SQUID data as an independent component even in the presence of severe motion, cardiac and respiratory artifacts. The accuracy of the method is analyzed by comparing FICA-extracted versus electrode-measured respiratory signals. It is concluded that, with this method, reliable results may be obtained for a wide array of magnetic recording scenarios.
引用
收藏
页码:1059 / 1073
页数:15
相关论文
共 55 条
[41]  
Makeig S, 1996, ADV NEUR IN, V8, P145
[42]  
MORISSON DF, 1967, MULTIVARIATE STAT ME
[43]   The effect of artifact rejection by signal-space projection on source localization accuracy in MEG measurements [J].
Nolte, G ;
Curio, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (04) :400-408
[44]  
PALMER RL, 2005, THESIS VANDERBILT U
[45]   Electrogastrography: a document prepared by the gastric section of the American Motility Society Clinical GI Motility Testing Task Force [J].
Parkman, HP ;
Hasler, WL ;
Barnett, JL ;
Eaker, EY .
NEUROGASTROENTEROLOGY AND MOTILITY, 2003, 15 (02) :89-102
[46]   Origins and patterns of spontaneous and drug-induced canine gastric myoelectrical dysrhythmia [J].
Qian, LW ;
Pasricha, PJ ;
Chen, JDZ .
DIGESTIVE DISEASES AND SCIENCES, 2003, 48 (03) :508-515
[47]   BIHARMONIC SPLINE INTERPOLATION OF GEOS-3 AND SEASAT ALTIMETER DATA [J].
SANDWELL, DT .
GEOPHYSICAL RESEARCH LETTERS, 1987, 14 (02) :139-142
[48]   Diagnosis and treatment of chronic gastroparesis and chronic intestinal pseudo-obstruction [J].
Smith, DS ;
Williams, CS ;
Ferris, CD .
GASTROENTEROLOGY CLINICS OF NORTH AMERICA, 2003, 32 (02) :619-+
[49]  
Staton D, 1995, STUD APPL ELECTROMAG, V7, P748
[50]   Independent component approach to the analysis of EEG and MEG recordings [J].
Vigário, R ;
Särelä, J ;
Jousmäki, V ;
Hämäläinen, M ;
Oja, E .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (05) :589-593