Use and Development of Fouling Index in Predicting Membrane Fouling

被引:27
|
作者
Koo, Chai Hoon [1 ,2 ]
Mohammad, Abdul Wahab [1 ]
Suja', Fatihah [3 ]
Talib, Meor Zainal Meor [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Chem & Proc Engn, Ukm Bangi 43600, Selangor Darul, Malaysia
[2] Univ Tunku Abdul Rahman, Fac Sci & Engn, Dept Civil Engn, Kuala Lumpur, Malaysia
[3] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Dept Civil & Struct Engn, Ukm Bangi 43600, Selangor Darul, Malaysia
来源
SEPARATION AND PURIFICATION REVIEWS | 2013年 / 42卷 / 04期
关键词
Fouling index; fouling potential; silt density index; modified fouling index; crossflow sampler; membrane fouling; pretreatment; REVERSE-OSMOSIS MEMBRANES; ATOMIC-FORCE MICROSCOPE; NATURAL ORGANIC-MATTER; SILT DENSITY INDEX; WASTE-WATER; MFI-UF; ULTRAFILTRATION MEMBRANES; FLUX DECLINE; RO MEMBRANES; FEED WATER;
D O I
10.1080/15422119.2012.690359
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Membrane fouling has been recognized as an inevitable problem impairing all membrane processes. Fouling control strategies have been adopted to resolve membrane fouling. Fouling index is one of the most popular fouling prediction tools used to predict the fouling potential of feed water in membrane filtration systems. This paper provides an overview of the past and present developments of fouling indices measurement techniques as the membrane fouling prediction tool in reverse osmosis/nanofiltration process. This paper also addresses the possible fouling mechanisms and type of fouling in water filtration processes, start-of-art techniques used to assess fouling mechanisms and methods to predict fouling. The fouling prediction methods highlighted are silt density index (SDI) and modified fouling index (MFI). These fouling indices are correlated with their applications in evaluating the pretreatment efficiency and the flux decline predictions of a feed. Even though there are a number of researchers focusing on the measurement of MFI, the MFI obtained was not correlated to the quality of feed empirically. An appropriate index should be capable of being used as an input to mathematical models for predicting the degree of fouling in a discrete form. The future direction and potential use of fouling indices are also discussed.
引用
收藏
页码:296 / 339
页数:44
相关论文
共 50 条
  • [1] Evaluation of organic matter fouling potential by membrane fouling index
    Park, C.
    Kim, H.
    Hong, S.
    Lee, S.
    Choi, S.-I.
    Water Science and Technology: Water Supply, 2007, 7 (5-6): : 27 - 33
  • [2] Fouling potential evaluation by cake fouling index: Theoretical development, measurements, and its implications for fouling mechanisms
    Jin, Yongxun
    Ju, Younggil
    Lee, Hyunkyung
    Hong, Seungkwan
    JOURNAL OF MEMBRANE SCIENCE, 2015, 490 : 57 - 64
  • [3] Proposing a new fouling index in a membrane bioreactor (MBR) based on mechanistic fouling model
    Kim, M. J.
    Kang, O. Y.
    Rao, B. S.
    Kim, J. R.
    Hwang, H. J.
    Kim, M. H.
    Yoo, C. K.
    DESALINATION AND WATER TREATMENT, 2011, 33 (1-3) : 209 - 217
  • [4] A modified fouling index (MFI40) and fouling predicting approach for ultrafiltration of secondary effluents
    Cai, B. J.
    Baudin, I.
    Ng, H. Y.
    JOURNAL OF WATER REUSE AND DESALINATION, 2019, 9 (01): : 67 - 82
  • [5] The effects of soluble organic matters on membrane fouling index
    Chuang, Shun-Hsing
    Chang, Wei-Chin
    Chang, Min-Chao
    Sung, Ming-An
    BIORESOURCE TECHNOLOGY, 2009, 100 (05) : 1875 - 1877
  • [6] Variability and limits of the unified membrane fouling index: application to the reduction of low-pressure membrane fouling by ozonation and biofiltration
    Geismar, Noam
    Berube, Pierre R.
    Barbeau, Benoit
    DESALINATION AND WATER TREATMENT, 2012, 43 (1-3) : 91 - 101
  • [7] Development of combined fouling model in a membrane bioreactor
    Kim, M. J.
    Yoo, G. Y.
    Yoo, C. K.
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2011, 6 (03) : 423 - 432
  • [8] Research on the factors influencing nanofiltration membrane fouling and the prediction of membrane fouling
    Zheng, Wenjing
    Chen, Yan
    Xu, Xiaohu
    Peng, Xing
    Niu, Yalin
    Xu, Pengcheng
    Li, Tian
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 59
  • [9] The Membrane Fouling Simulator: a suitable tool for prediction and characterisation of membrane fouling
    Vrouwenvelder, J. S.
    Bakker, S. M.
    Cauchard, M.
    Le Grand, R.
    Apacandie, M.
    Idrissi, M.
    Lagrave, S.
    Wessels, L. P.
    van Paassen, J. A. M.
    Kruithof, J. C.
    van Loosdrecht, M. C. M.
    WATER SCIENCE AND TECHNOLOGY, 2007, 55 (8-9) : 197 - 205
  • [10] Predicting colloidal fouling of tap water by silt density index (SDI): Pore blocking in a membrane process
    Habib, Muddasar
    Habib, Unsia
    Memon, Abdul Rehman
    Amin, Usman
    Karim, Zahid
    Khan, Amad Ullah
    Naveed, Sayed
    Ali, Sultan
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2013, 1 (1-2) : 33 - 37