Liquid-liquid-solid microextraction and detection of nerve agent simulants by on-membrane Fourier transform infrared spectroscopy

被引:5
作者
Garg, Prabhat [1 ]
Purohit, Ajay [1 ]
Tak, Vijay K. [1 ]
Kumar, Ajeet [1 ]
Dubey, D. K. [1 ]
机构
[1] Def Res & Dev Estab, Vertox Lab, Gwalior 474002, India
关键词
Chemical warfare agents; Liquid-liquid-solid phase microextraction; Infrared; Organophosphonates; CHEMICAL WARFARE AGENTS; PHASE EXTRACTION; GAS-CHROMATOGRAPHY; WATER; SAMPLES; IDENTIFICATION; VERIFICATION; PESTICIDES; SILICA;
D O I
10.1016/j.aca.2012.09.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A coupling of novel liquid-liquid-solid microextraction (LLSME) technique based on porous hydrophobic membrane and Fourier-transform infrared spectroscopy has been presented for the detection, identification and quantification of markers and simulants of nerve agents. Two isomers O,O'-dihexyl methylphosphonate (DHMP) and O,O'-dipentyl isopropylphosphonate (DPIPP) were chosen as model analytes for the study. In the present technique, organic phase was immobilised within the pores of membrane after fixing it in an assembly, which was then immersed into aqueous sample of target analytes for extraction. The analytes were directly determined on the surface of membrane by FTIR spectroscopy without elution. On comparison with solid phase microextraction (SPME), LLSME was found to be much more efficient. The method was optimised and quantitative analyses were performed using calibration curves obtained via Beer's law and employing processing of spectra obtained, via a multivariate calibration technique partial least square (PLS). Relative standard deviations (RSDs) for intraday repeatability and interday reproducibility were found to be in the range of 0.20-0.50% and 0.20-0.60%, respectively. Limit of detection (LOD) was achieved up to 15 ng mL(-1). Applicability of the method was tested with an unknown real sample obtained in an international official proficiency test (OPT). (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 42 条
[1]   On-line and off-line solid-phase extraction with styrene-divinylbenzene-membrane extraction disks for determining pesticides in water by reversed-phase liquid chromatography diode-array detection [J].
Aguilar, C ;
Borrull, F ;
Marce, RM .
JOURNAL OF CHROMATOGRAPHY A, 1996, 754 (1-2) :77-84
[2]   Dispersive Solid Phase Extraction for In-Sorbent Surface Attenuated Total Reflection Infrared Detection [J].
Alcudia-Leon, M. C. ;
Lucena, R. ;
Cardenas, S. ;
Valcarcel, M. .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1184-1190
[3]  
[Anonymous], 2006, EV RES 18 OFF OPCW T
[4]   Determination of edible oil parameters by near infrared spectrometry [J].
Armenta, S. ;
Garrigues, S. ;
de la Guardia, M. .
ANALYTICA CHIMICA ACTA, 2007, 596 (02) :330-337
[5]   Derivatisation reactions in the chromatographic analysis of chemical warfare agents and their degradation products [J].
Black, RM ;
Muir, B .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :253-281
[6]   A FIBER OPTIC EVANESCENT FIELD ABSORPTION SENSOR FOR MONITORING ORGANIC CONTAMINANTS IN WATER [J].
BURCK, J ;
CONZEN, JP ;
ACHE, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (4-5) :394-400
[7]   Selective extraction of triazine herbicides based on a combination of membrane assisted solvent extraction and molecularly imprinted solid phase extraction [J].
Chimuka, Luke ;
van Pinxteren, Manuela ;
Billing, Johan ;
Yilmaz, Ecevit ;
Jonsson, Jan Ake .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (05) :647-653
[8]   Hollow fiber-mediated liquid-phase microextraction of chemical warfare agents from water [J].
Dubey, DK ;
Pardasani, D ;
Gupta, AK ;
Palit, M ;
Kanaujia, PK ;
Tak, V .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1107 (1-2) :29-35
[9]   On-matrix derivatisation-extraction of precursors of nitrogen- and sulfur-mustards for verification of chemical weapons convention [J].
Dubey, DK ;
Pardasani, D ;
Palit, M ;
Gupta, AK ;
Jain, R .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1076 (1-2) :27-33
[10]  
Durst HD, 1998, ANAL LETT, V31, P1429