Variance components associated with long-echo-time MR spectroscopic imaging in human brain at 1.5T and 3T

被引:0
作者
Thrippleton, Michael J. [1 ]
Parikh, Jehill P. [1 ]
Semple, Scott I. K. [2 ]
Harris, Bridget A. [3 ]
Andrews, Peter J. D. [1 ]
Wardlaw, Joanna M. [1 ]
Marshall, Ian [1 ]
机构
[1] Univ Edinburgh, Ctr Clin Brain Sci, Edinburgh, Midlothian, Scotland
[2] Univ Edinburgh, Clin Res Imaging Ctr, Edinburgh, Midlothian, Scotland
[3] Univ Edinburgh, Crit Care Med, Edinburgh, Midlothian, Scotland
关键词
REFOCUSING PULSES; WHITE-MATTER; REPRODUCIBILITY; QUANTIFICATION; METABOLITES; RELIABILITY; ACCURATE; IMAGES; ROBUST; COILS;
D O I
10.1371/journal.pone.0189872
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Object Magnetic resonance spectroscopic imaging (MRSI) is increasingly used in medicine and clinical research. Previous reliability studies have used small samples and focussed on limited aspects of variability; information regarding 1.5T versus 3T performance is lacking. The aim of the present work was to measure the inter-session, intra-session, inter-subject, within-brain and residual variance components using both 1.5T and 3T MR scanners. Materials and methods Eleven healthy volunteers were invited for MRSI scanning on three occasions at both 1.5T and 3T, with four scans acquired at each visit. We measured variance components, correcting for grey matter and white matter content of voxels, of metabolite peak areas and peak area ratios. Results Residual variance was in general the largest component at 1.5T (8.6-24.6%), while withinbrain variation was the largest component at 3T (12.0-24.7%). Inter-subject variation was around 5%, while inter- and intra-session variance were both generally small. Conclusion Multiple variance contributions associated with MRSI measurements were quantified and the performance of 1.5T and 3T MRI scanners compared using data from the same group of subjects. Residual error is much lower at 3T, but other variance components remain important.
引用
收藏
页数:11
相关论文
共 47 条
[41]   Effect of intravenous gadoxetate disodium and flip angle on hepatic proton density fat fraction estimation with six-echo, gradient-recalled-echo, magnitude-based MR imaging at 3T [J].
Park, Charlie C. ;
Hamilton, Gavin ;
Desai, Ajinkya ;
Zand, Kevin A. ;
Wolfson, Tanya ;
Hooker, Jonathan C. ;
Costa, Eduardo ;
Heba, Elhamy ;
Clark, Lisa ;
Gamst, Anthony ;
Loomba, Rohit ;
Middleton, Michael S. ;
Sirlin, Claude B. .
ABDOMINAL RADIOLOGY, 2017, 42 (04) :1189-1198
[42]   Time-efficient, high-resolution 3T whole-brain relaxometry using Cartesian 3D MR Spin TomogrAphy in Time-Domain (MR-STAT) with cerebrospinal fluid suppression [J].
Liu, Hongyan ;
Versteeg, Edwin ;
Fuderer, Miha ;
van der Heide, Oscar ;
Schilder, Martin B. ;
van den Berg, Cornelis A. T. ;
Sbrizzi, Alessandro .
MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (05) :2008-2019
[43]   Ultra-short T2 components imaging of the whole brain using 3D dual-echo UTE MRI with rosette k-space pattern [J].
Shen, Xin ;
Ozen, Ali Caglar ;
Sunjar, Antonia ;
Ilbey, Serhat ;
Sawiak, Stephen ;
Shi, Riyi ;
Chiew, Mark ;
Emir, Uzay .
MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (02) :508-521
[44]   Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T* [J].
Niess, Fabian ;
Strasser, Bernhard ;
Hingerl, Lukas ;
Niess, Eva ;
Motyka, Stanislav ;
Hangel, Gilbert ;
Krssak, Martin ;
Gruber, Stephan ;
Spurny-Dworak, Benjamin ;
Trattnig, Siegfried ;
Scherer, Thomas ;
Lanzenberger, Rupert ;
Bogner, Wolfgang .
NEUROIMAGE, 2023, 277
[45]   B1 and T1 Insensitive Water and Lipid Suppression Using Optimized Multiple Frequency-Selective Preparation Pulses for Whole-Brain 1H Spectroscopic Imaging at 3T [J].
Gu, Meng ;
Spielman, Daniel M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) :462-466
[46]   Rapid 3D in vivo 1H human lung respiratory imaging at 1.5T using ultra-fast balanced steady-state free precession [J].
Pusterla, Orso ;
Bauman, Grzegorz ;
Wielpuetz, Mark O. ;
Nyilas, Sylvia ;
Latzin, Philipp ;
Heussel, Claus P. ;
Bieri, Oliver .
MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) :1059-1069
[47]   3D 31P MR spectroscopic imaging of the human brain at 3 T with a 31P receive array: An assessment of 1H decoupling, T1 relaxation times, 1H-31P nuclear Overhauser effects and NAD+ [J].
Peeters, Tom H. ;
van Uden, Mark J. ;
Rijpma, Anne ;
Scheenen, Tom W. J. ;
Heerschap, Arend .
NMR IN BIOMEDICINE, 2021, 34 (05)