Cardiac troponin I in asphyxiated neonates

被引:42
|
作者
Trevisanuto, D
Picco, G
Golin, R
Doglioni, N
Altinier, S
Zaninotto, M
Zanardo, V
机构
[1] Univ Padua, Sch Med, Dept Pediat, IT-35128 Padua, Italy
[2] Univ Padua, Sch Med, Dept Lab Med, IT-35128 Padua, Italy
[3] Azienda Osped Padova, Padua, Italy
来源
BIOLOGY OF THE NEONATE | 2006年 / 89卷 / 03期
关键词
asphyxia; cardiac tropin I;
D O I
10.1159/000089795
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Cardiac troponins T (cTnT) and I (cTnI) are well-established markers in detecting myocardial ischemic damage in adults. Perinatal asphyxia is associated with cardiac dysfunction. Objectives: To evaluate serum concentrations of cTnI in asphyxiated neonates and to investigate whether cTnI is correlated with the traditional markers of asphyxia. Methods: Blood samples were collected from 13 asphyxiated neonates (umbilical artery pH<7.18 and either a 1-min Apgar score <4 or a 5-min Apgar score <7) and 39 controls. Data on gestation, birth weight, sex, Apgar scores, mode of delivery, umbilical pH, creatinine, serum activity of aspartate and alanine aminotransferase, and QTc interval were investigated. Results: Median (range) cTnI concentrations were significantly higher in asphyxiated neonates with respect to healthy infants: 0.36 mu g/ l (0.05-11) versus 0.04 mu g/ l (0.04-0.06); p<0.01. In asphyxiated babies, no statistically significant correlations were found between concentrations of cTnI and the other markers of asphyxia. Conclusions: In asphyxiated neonates, cTnI concentrations are higher with respect to healthy infants, suggesting the presence of myocardial damage in this group of high-risk patients. cTnI does not correlate with the traditional markers of asphyxia. Copyright (C) 2006 S. Karger AG, Basel.
引用
收藏
页码:190 / 193
页数:4
相关论文
共 50 条
  • [21] Degradation of cardiac troponin I in serum complicates comparisons of cardiac troponin I assays
    Shi, QW
    Ling, MF
    Zhang, XC
    Zhang, MY
    Kadijevic, L
    Liu, SG
    Laurino, JP
    CLINICAL CHEMISTRY, 1999, 45 (07) : 1018 - 1025
  • [22] Renal failure in asphyxiated neonates
    Gupta, BD
    Sharma, P
    Bagla, J
    Parakh, M
    Soni, JP
    INDIAN PEDIATRICS, 2005, 42 (09) : 928 - 934
  • [23] Serum Cardiac Troponin I Levels in Neonates with Perinatal Asphyxia; A Cross-Sectional Study
    Marzban, Asghar
    Jafari, Nahid
    Zareakbari, Mahnaz
    IRANIAN JOURNAL OF NEONATOLOGY, 2025, 16 (01) : 19 - 26
  • [24] Perinatal serum estradiol and perioperative serum troponin I in neonates undergoing repair of cardiac defects
    Vessey, J
    Sun, LS
    Saraiya, N
    Almeida, GM
    Pesce, MA
    Pasamba, B
    ANESTHESIOLOGY, 1999, 91 (3A) : U498 - U498
  • [25] USE OF NALOXONE IN ASPHYXIATED NEONATES
    GRYLACK, L
    JOURNAL OF PEDIATRICS, 1989, 114 (03): : 509 - 509
  • [26] Echocardiographic patterns in asphyxiated neonates
    Masyhur, Maswin
    Amir, Idham
    Putra, Sukman Tulus
    Tumbelaka, Alan Roland
    PAEDIATRICA INDONESIANA, 2009, 49 (04) : 214 - 218
  • [27] Reply: The complementary role of cardiac troponin I and cardiac troponin T
    Tveit, Sjur H.
    Myhre, Peder L.
    Rosjo, Helge
    Omland, Torbjorn
    CLINICAL BIOCHEMISTRY, 2020, 78 : 42 - 42
  • [28] Interpretation of cardiac troponin measurements in neonates - The devil is in the details
    Gaze, DC
    Collinson, PO
    BIOLOGY OF THE NEONATE, 2006, 89 (03): : 194 - 196
  • [29] Cardiac troponin T on Elecsys 2010: comparison with cardiac troponin I
    Cauliez, B
    Hue, G
    Lavoinne, A
    ANNALES DE BIOLOGIE CLINIQUE, 1998, 56 (06) : 711 - 715
  • [30] Modification of cardiac troponin C upon binding cardiac troponin T and PKC phosphorylated cardiac troponin I
    Finley, NL
    Ward, DG
    Trayer, IP
    Rosevear, PR
    BIOPHYSICAL JOURNAL, 2003, 84 (02) : 566A - 566A