Different techniques of distal aortic repair in acute type A dissection:: impact on late aortic morphology and reoperation

被引:35
作者
Nguyen, B [1 ]
Müller, M [1 ]
Kipfer, B [1 ]
Berdat, P [1 ]
Walpoth, B [1 ]
Althaus, U [1 ]
Carrel, T [1 ]
机构
[1] Univ Hosp Bern, Clin Thorac & Cardiovasc Surg, CH-3010 Bern, Switzerland
关键词
aortic dissection; surgical repair; magnetic resonance imaging; morphology of the distal aorta;
D O I
10.1016/S1010-7940(99)00036-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare three different techniques of distal aortic repair in acute type A (de Bakey type I) aortic dissection and to evaluate their impact on the Tate morphology of the aortic arch and descending aorta and on the incidence of reoperation. Methods: From 65 patients operated on due to an acute type A aortic dissection between 1989 and 1993, 54 long-term survivors underwent clinical and radiologic follow-up examination after a mean postoperative interval of 62 +/- 16 months. The surgical techniques of distal aortic reconstruction included closed repair using Teflon felt reinforcement under moderate hypothermic cardiopulmonary bypass (n = 20) and open repair in deep hypothermic circulatory arrest using either Teflon felt reinforcement (n = 16) or gelatin-resorcin-formaldehyde (GRF) glue (n = Is) to readapt the dissected aortic layers. In all patients, MR imaging was performed on a 1.5-T whole body imaging system for the evaluation of the morphology and function of the heart, aorta and supraaortic branches. Results: Overall hospital mortality following surgical repair of type A aortic dissection was 15.4% during this time period. The highest rate of persistent false lumen perfusion (17/20, 85%) and presence of an intimal flap in the aortic arch (13/20, 65%) was observed in patients following closed repair of acute ascending aortic dissection, whereas the lowest rate of such findings was demonstrated in patients who had undergone open distal aortic repair using biological glue (false lumen perfusion 10/18, 55% and intimal flap in the arch 2/18, 11%). Redo-surgery was significantly reduced in the open repair group using GRF glue (1/18, 5.5%) as compared with the Teflon felt repair group (3/16, 18%) and the closed repair group (6/20, 30%). Conclusions: In patients with acute type A dissection, open distal aortic repair using GRF-glue favourably influences both (1) the severity of late morphologic alterations in the downstream aorta and (2) the incidence of reoperation. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:496 / 500
页数:5
相关论文
共 22 条
[1]   LATE REOPERATIONS IN PATIENTS WITH AORTIC DISSECTION [J].
BACHET, J ;
TERMIGNON, JL ;
GOUDOT, B ;
DREYFUS, G ;
PIQUOIS, A ;
BRODATY, D ;
DUBOIS, C ;
DELENTDECKER, P ;
GUILMET, D .
JOURNAL OF CARDIAC SURGERY, 1994, 9 (06) :740-747
[2]   Twenty-year follow-up of acute type a dissection: The incidence and extent of distal aortic disease using magnetic resonance imaging [J].
Barron, DJ ;
Livesey, SA ;
Brown, IW ;
Delaney, DJ ;
Lamb, RK ;
Monro, JL .
JOURNAL OF CARDIAC SURGERY, 1997, 12 (03) :147-159
[3]  
BORST HG, 1996, SURG TREATMENT AORTI, P117
[4]   RETROGRADE ASCENDING AORTIC DISSECTION - A DIAGNOSTIC AND THERAPEUTIC CHALLENGE [J].
CARREL, T ;
PASIC, M ;
VOGT, P ;
VONSEGESSER, L ;
LINKA, A ;
RITTER, M ;
JENNI, R ;
TURINA, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1993, 7 (03) :146-152
[5]   REOPERATIONS AFTER OPERATION ON THE THORACIC AORTA - ETIOLOGY, SURGICAL TECHNIQUES, AND PREVENTION [J].
CARREL, T ;
PASIC, M ;
JENNI, R ;
TKEBUCHAVA, T ;
TURINA, MI ;
COOLEY, DA ;
BENTALL, HH ;
SEGUIN, JR .
ANNALS OF THORACIC SURGERY, 1993, 56 (02) :259-269
[6]  
CRAWFORD ES, 1992, J THORAC CARDIOV SUR, V104, P46
[7]   EFFECT OF MEDICAL AND SURGICAL THERAPY ON AORTIC DISSECTION EVALUATED BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY - IMPLICATIONS FOR PROGNOSIS AND THERAPY [J].
ERBEL, R ;
OELERT, H ;
MEYER, J ;
PUTH, M ;
MOHRKATOLY, S ;
HAUSMANN, D ;
DANIEL, W ;
MAFFEI, S ;
CARUSO, A ;
COVINO, FE ;
DIALETTO, G ;
IACONO, C ;
COTRUFO, M ;
BARONI, M ;
TERRAZZI, M ;
FRASER, A ;
TAAMS, M ;
SLAVICH, G ;
SUTHERLAND, G ;
ROELANDT, J ;
MARCAGGI, X .
CIRCULATION, 1993, 87 (05) :1604-1615
[8]   SIGNIFICANCE OF DISTAL FALSE LUMEN AFTER TYPE-A DISSECTION REPAIR [J].
ERGIN, MA ;
PHILLIPS, RA ;
GALLA, D ;
GRIEPP, RB ;
LANSMAN, SL ;
MENDELSON, DS ;
QUINTANA, CS .
ANNALS OF THORACIC SURGERY, 1994, 57 (04) :820-825
[9]   TYPE-A DISSECTION OF THE THORACIC AORTA - USE OF MR-IMAGING FOR LONG-TERM FOLLOW-UP [J].
GAUBERT, JY ;
MOULIN, G ;
MESANA, T ;
CHAGNAUD, C ;
CAUS, T ;
DELANNOY, L ;
BLIN, D ;
BARTOLI, JM ;
KASBARIAN, M .
RADIOLOGY, 1995, 196 (02) :363-369
[10]   TOTAL ARCH GRAFT REPLACEMENT IN PATIENTS WITH ACUTE TYPE-A AORTIC DISSECTION [J].
KAZUI, T ;
KIMURA, N ;
YAMADA, O ;
KOMATSU, S .
ANNALS OF THORACIC SURGERY, 1994, 58 (05) :1462-1468